GLC75 Commercial/GLM75 Medical 75 Watt Single Output Global Performance Switchers FEATURES: Cost-effective single-output power source 3.4 x 5.75 x 1.56 (meets 1U applications) Universal input 90-264 Vac 2-year warranty Complies with EN61000-3-2 Class A Also available in multiple output versions Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Commercial Approved to UL1950, CSA22.2 No. 234 and IEC950, EN60950 Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601 SPECIFICATIONS: marked to LVD Ac Input 90-264 Vac, 47-63 Hz single phase. Inrush Current Input Current Inrush limited by internal thermistors. Inrush at 240 Vac, Maximum input current at 120 Vac, 60 Hz with full rated averaged over the first ac half-cycle under cold start output load not to exceed 2.3 A. conditions will not exceed 37 A. Output Power Temperature Coefficient Normal continuous output power is 75 W for unrestricted 0.03%/C typical on all outputs. natural convection cooling 110 W with 26 cfm airflow. Power Fail Output Regulation A standard TTL or CMOS compatible output goes low Regulation measured by changing from 5% to 50% load (< 0.5 V) 5ms before output voltage drops more than 4% or 50% load to full load in either direction. below nominal voltage upon loss of ac power. Signal is factory set to trip on 84 to 94 Vac brown-out depending Overload Protection upon incoming line impedance and distortion. Other Factory set to begin power limiting at approximately 120 settings are available through adjustment of built-in W (GLC 75-5 is set at approximately 100 W). Fully potentiometer (consult factory for assistance). Output will protected against short circuit and output overload. Short stay low for 20 ms minimum. circuit protection is cycling type power limit. EMI/EMC Compliance Output Noise All models include built-in EMI filtering to meet the 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential following emissions requirements: mode. Measured with noise probe directly across output EMI SPECIFICATIONS COMPLIANCE LEVEL terminals of the power supply. Conducted Emissions GLC75 EN55022 Class B FCC Class B Conducted Emissions GLM75 EN55011 Class B FCC Class B Transient Response Static Discharge EN61000-4-2, 6 kV contact, 8 kV air Main Output: 500 s typical response time for return to RF Field Susceptibility EN61000-4-3, 3 V/meter within 0.5% of final value for a 50% load step change, i/ Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz t<0.2 A/s. Maximum voltage deviation is 3.5%. Startup/ Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. shutdown overshoot less than 3%. Line Frequency Harmonics EN61000-3-2 Class A Overvoltage Protection Commercial Safety Standard on all models. All GLC models are approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. Consult factory for Voltage Adjust approval status. Factory set on standard unit however, potentiometer adjusts voltage 5% minimum. Consult factory for Medical Leakage Current application assistance. 70 A 264 V 50 Hz (normal conditions). Efficiency Medical Safety 72-85% depending on model. All GLM models are approved to UL2601-1, CSA-C22.2 No. 601.1, IEC601-1 and EN60601-1. Consult factory for Input Protection approval status. Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unitfuse does not blow on overload or short circuit. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 40GLC75 Commercial/GLM75 Medical 75 Watt Single Output Commercial Medical Output Output Maximum Output Maximum Output Total Output Model Model Minimum (A) (B) Peak V1 OVP Set Noise P-P Regulation GLC75-5 GLM75-5 5A.1 V 0A1A3.7 1A9.6 2V16V.2 0.6 5%0 m 1 GLC75-12 GLM75-121A2 V 0A6A.3 9A.1 9V.51V5.6 1.11%20 m 1 GLC75-15 GLM75-151A5 V 0A5A7A.3 7V.71V8.5 1.51%50 m 1 GLC75-24 GLM75-242A4 V 0A3A.1 4A.6 5V2V8 2.5 2%40 m 1 GLC75-28 GLM75-282A8 V 0A2A.7 4A4V.43V4 2.8 2%80 m 1 A. Rating with unrestricted convection cooling. Total power not to exceed 75 W. B. Rating with 26 cfm forced-air cooling. Total power not to exceed 110 W. GLC75/GLM75 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o o Temperature (A) 0 to 50 C -40 to +85 C HHumidity (A)0Hto 95% R 0 to 95% R A. Units should be allowed to warm up/operate under non-condensing conditions Sghock (B) 20 40 g before application of power. pk pk B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 Atltitude-t500 to 10,000 f -500 to 40,000 f orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes, 2 2 Vgibration (C) 1.5 , 0.003 g/gHz 5 , 0.026 g /Hz rms rms total 6 shocks. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 41