GPC140 Commercial/GPM140 Medical 140 Watt Global Performance Switchers FEATURES: Wide-range ac input 85-264 Vac 2-year warranty Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Single outputs Commercial Approved to UL1950, IEC950, EN60950 and CSA22.2-234 L3 Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601 marked to LVD SPECIFICATIONS: Ac Input Output Noise 85-264 Vac, 47-63 Hz single phase. 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output Input Current terminals of the power supply. Maximum input current at 120 Vac, 60 Hz with full rated output load: 3.7 A Transient Response Main output500 s typical response time for return to Hold-Up Time within 0.5% of final value for a 50% load step change. i/ 20ms minimum from loss of ac input at full load, nominal t<0.2 A/s. Maximum voltage deviation is 3.5%. Startup/ shutdown overshoot less than 3%. line (115 Vac). Output Power Remote Sense 140 W convection 160 W with air flow. Peak ratings are Provided as a standard feature. for 60 s maximum duration, 10% duty cycle. Voltage Adjustment Overload Protection Built-in potentiometer adjusts voltage 5%. Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on Overload Protection output 1. Recovery after fault is automatic. Factory set to begin power limiting at approximately 175 W. Overvoltage Protection EMI/EMC Compliance Main outputs: 130% 15% typical. All models include built-in EMI filtering to meet the following emissions requirements: Efficiency EMI SPECIFICATIONS COMPLIANCE LEVEL 70% at full rated load, nominal input voltage, depending Conducted Emissions GPC140 EN55022 Class B FCC Class B on model and load distribution. Conducted Emissions GPM140 EN55011 Class B FCC Class B Static Discharge EN61000-4-2, 6 kV contact, 8 kV air Input Protection RF Field Susceptibility EN61000-4-3, 3 V/meter Internal ac fuse provided. Designed to blow only if a Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz catastrophic failure occurs in the unit. Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Inrush Current Commercial Leakage Current Inrush is limited by internal thermistors. Inrush at 240 Vac, 0.95 mA 254 Vac 60 Hz input. averaged over the first ac half-cycle under cold start conditions will not exceed 60 A. Commercial Safety Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 Temperature Coefficient and EN60950. UL file E135803 commercial CSA LR46516 all models. The output(s) are intended for 0.03%/C typical on all outputs. safety earthed Signal Output and Intermediate Circuits only. All dc outputs are SELV under normal and single Thermal Shutdown fault conditions. Provided as a standard feature. Designed to protect unit from prolonged overtemperature. Medical Leakage Current 60 A 254 Vac 60 Hz input. Environmental Designed for 0 to 50C operation at full rated output Medical Safety power derate output current and total output power by Approved to UL2601, CSA22.2 No. 601 Level 3 and 2.5% per C above 50C. See Environmental and IEC601. UL file E116994 CSA LR46516. The output(s) Packaging Specifications on next page. are intended for safety earthed Signal Output and Intermediate Circuits only. The output(s) are not accept- Power Fail able for patient connection without additional isolation. All TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms dc outputs are SELV under normal and single fault before output voltage drops more than 4% below conditions. nominal voltage upon loss of ac power. The signal is factory set to trip on 84 to 94 Vac brown-out depending upon incoming line impedance and distortion. Other settings are available to the user through adjustment of built-in potentiometer. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 56GPC140 Commercial/GPM140 Medical 140 Watt Multiple Output Commercial Medical Output Output Output Model Model Output Minimum Maximum (B) Maximum (C) Peak Noise P-P Total Regulation (A) GPC140-5 GPM140-5 5AV 0A2A6 3A0 3V25%0 m 2 GPC140-12 GPM140-121A2 V 0A1A1.7 1A3.4 1V4.61%20 m 2 GPC140-15 GPM140-151A5 V 0A9A.3 1A0.7 1V1.71%50 m 2 GPC140-24 GPM140-242A4 V 0A5A.8 6A.7 7V.32%40 m 2 GPC140-28 GPM140-282A8 V 0A5A5A.7 6V.32%80 m 2 A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Unrestricted natural convection cooling. C. Requires 26cfm moving air. GPC140/GPM140 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o Tsemperature (A)S5ee individual spec -40 to +8 C HHumidity (A)0Hto 95% R 0 to 95% R A. Units should be allowed to warm up/operate under non-condensing conditions Sghock (B) 20 40 g pk pk before application of power. B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 Atltitude-t500 to 10,000 f -500 to 40,000 f orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. 2 2 C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes, Vgibration (C) 1.5 , 0.003 g/gHz 5 , 0.026 g /Hz rms rms total 6 shocks. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 57