GPC50 Commercial 50 WATT GLOBAL PERFORMANCE SWITCHERS GLOBAL PERFORMANCE SWITCHERS Summary: Wide-range ac input 85-264 Vac 2-year warranty Approved to UL1950, IEC950 and CSA22.2-234 L3 Meets FCC and CISPR22 Class B conducted emissions requirements Triple outputs RoHS Compliant Model Availalbe (G suffix) marked to LVD SPECIFICATIONS Ac Input Environmental 85-264 Vac, 47-63 Hz single phase. Designed for 0 to 50C operation at full rated output power derate output current and total output power by 2.5% per C above 50C. See Environmental and Input Current Packaging Specifications on next page. Maximum input current at 120 Vac, 60 Hz with full rated output load: 1.5 A Output Noise Hold-Up Time 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise 20 ms minimum from loss of ac input at full load, nominal line (115 Vac). probe directly across output terminals of the power supply. Output Power 50 W continuous, 60 W peak. Peak ratings are for 60 s maximum duration, Transient Response 10% duty cycle. During peak load condition, output regulation may exceed Main output500 s typical response time for return to within 0.5% of final value total regulation limits. for a 50% load step change. i/ t<0.2 A/s. Maximum voltage deviation is 3.5%. Startup/ shutdown overshoot less than 3%. Overload Protection Fully protected against short circuit and output overload. Voltage Adjustment Short circuit protection is cycling type power limit on outputs 1 & 2 foldback Built-in potentiometer adjusts voltage 5% on outputs 1 & 2. type on output 3. Recovery after fault is automatic. See output ratings chart for additional notes or conditions. EMI/EMC Compliance Overvoltage Protection. All models include built-in EMI filtering to meet the following emissions require - Crowbar provided on V1. ments: Efficiency EMI SPECIFICATIONS COMPLIANCE LEVEL 65% at full rated load, nominal input voltage, depending on model and load distribution. Conducted Emissions EN55022 Class B FCC Class B Static Discharge EN61000-4-2, 6 kV contact, 8 kV air Turn-on Time RF Field Susceptibility EN61000-4-3, 3 V/meter Less than 1 second at 120 Vac, 25C (inversely proportional to input voltage Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kH and thermistor temperature). Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Input Protection Internal ac fuse provided. Designed to blow only if a catastrophic failure oc- Leakage Current curs in the unit. 0.7 mA 254 Vac 60 Hz input. Inrush Current Safety Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950 UL file conditions will not exceed 34 A. E135803 commercial CSA LR46516 all models. All DC outputs are SELV under normal and single fault conditions. Temperature Coefficient 0.03%/C typical on all outputs. O All specifications are typical at nominal input, full load at 25 C unless otherwise statedCommercial Output Output Total Model Output No. Output Minimum Maximum Output Peak Noise P-P Regulation (A) Notes GPC50A 1 +5 V 0.4 A 5 A 7 A 50 mV 2% 2 +12 V 0 A 2 A 3 A 120 mV 5% B,C,D 3 -12 V 0 A 0.5 A 1 A 120 mV 3% D GPC50F 1 +5 V 0.4 A 5 A 7 A 50 mV 2% 2 +12 V 0 A 1.2 A 1.5 A 120 mV 3% D 3 -12 V 0 A 0.5 A 1 A 120 mV 3% D A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. To maintain these regulation conditions, the 5.1 V current must be at least 1/4 of V2 and not greater than 5 times the V2 current. C. Requires +5 V to be adjusted within 1% with at least a 0.4 A load to maintain regulation on this output since its centering voltage tracks the V1 adjustment. D. Requires +5 V to have at least a 0.4 A load. E. Add G suffix to part number for RoHS compliant model. Contact factory for availability. GPC50 MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING Temperature (A) See individual specs. -40 to +85C A. Units should be allowed to warm up/operate under non-condensing Humidity (A) 0 to 95% RH 0 to 95% RH conditions before application of power. B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to Shock (C) 20 g 40 g pk pk 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and Altitude -500 to 10,000 ft -500 to 40,000 ft 1 hr./axis non-operating. 2 2 Vibration (B) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 rms rms orthogonal axes, total 6 shocks. SL Power Electronics, Inc. 6050 King Drive, Bldg. A, Ventura, Ca 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: condor condordc.com. Rev. 8/18/2009. Data Sheet 2009 SL Power Electrontics Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.