GPC55 Commercial/GPM55 Medical 55 Watt Global Performance Switchers GLOBAL PERFORMANCE SWITCHERS FEATURES: D C P o w e r S u p p l i e s Wide-range ac input 85-264 Vac 2-year warranty Conducted EMI complies with FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Commercial Approved to UL1950, IEC950 and CSA22.2-234 L3 Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601 Complies with EN61000-3-2 Class A Single and multiple outputs marked to LVD RoHS Compliant Model Available (G suffix) SPECIFICATIONS Ac Input Output Noise 85-264 Vac, 47-63 Hz single phase. 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. Input Current Transient Response Maximum input current at 120 Vac, 60 Hz with full rated output load: 1.7 A Main output500 s typical response time for return to within 0.5% of final value Hold-Up Time for a 50% load step change. i/t<0.2 A/s. Maximum voltage deviation is 3.5%. 20 ms minimum from loss of ac input at full load, nominal line (115 Vac). Startup/shutdown overshoot less than 3%. Output Power Voltage Adjustment 55 W continuous, 70 W peak. Peak ratings are for 60 s maximum duration, Built-in potentiometer adjusts voltage 5% on outputs 1 & 2. 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits. EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions require - Overload Protection ments: Fully protected against short circuit and output overload. Short circuit protec- EMI SPECIFICATIONS COMPLIANCE LEVEL tion is cycling type power limit on outputs 1 & 2 foldback type on outputs 3 & 4. Recovery after fault is automatic. See output ratings chart for Conducted Emissions GPC55 Static EN55022 Class B FCC Class B additional notes or conditions. Factory set to begin power limiting at ap- Conducted Emissions GPM55 EN55011 Class B FCC Class B proximately 75 W. Static Discharge EN61000-4-2, 6 kV contact, 8 kV air RF Field Susceptibility EN61000-4-3, 3 V/meter Overvoltage Protection Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Main outputs: 124% + 12% Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Efficiency Line Frequency Harmonics EN61000-3-2 Class A 70% at full rated load, nominal input voltage, depending on model and load distribution. Commercial Leakage Current Input Protection 0.7 mA 254 Vac 60 Hz input. Internal ac fuse provided. Designed to blow only if a catastrophic failure oc- Commercial Safety curs in the unit. Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. UL file Inrush Current E135803 commercial CSA LR46516 all models. All dc outputs are SELV under Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start normal and single fault conditions. conditions will not exceed 34 A. Medical Leakage Current Temperature Coefficient 35 A 254 Vac 60 Hz input. 0.03%/C typical on all outputs. Medical Safety Environmental Approved to UL2601, CSA22.2 No. 601 Level 3 and IEC601. UL file E116994 CSA Designed for 0 to 50C operation at full rated output power derate output LR46516. The output(s) are intended for safety earthed Signal Output and current and total output power by 2.5% per C above 50C. See Environmen- Intermediate Circuits only. The output(s) are not acceptable for patient connection tal and Packaging Specifications on next page. without additional isolation. All dc outputs are SELV under normal and single fault conditions. O All specifications are typical at nominal input, full load at 25 C unless otherwise statedCommercial Medical Output Output Output Total Model Model Output No. Output Minimum Maximun Peak Noise P-P Regulation (A) GPC55A GPM55A 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +12 V 0 A 3 A 5 A 120 mV 2% 3 +12 V 0 A 1 A 1.2 A 120 mV 3% 4 -12 V 0 A 1 A 1.2 A 120 mV 3% GPC55B GPM55B 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +12 V 0 A 3 A 5 A 120 mV 2% 3 -5 V 0 A 1 A 1.2 A 50 mV 3% 4 -12 V 0 A 1 A 1.2 A 120 mV 3% GPC55C GPM55C 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +15 V 0 A 3 A 5 A 150 mV 2% 3 -5 V 0 A 1 A 1.2 A 50 mV 3% 4 -15 V 0 A 1 A 1.2 A 150 mV 3% GPC55D GPM55D 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +24 V 0 A 1.5 A 5 A 240 mV 2% 3 +12 V 0 A 1 A 1.2 A 120 mV 3% 4 -12 V 0 A 1 A 1.2 A 120 mV 3% GPC55E GPM55E 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +24 V 0 A 1.5 A 5 A 120 mV 2% 3 +15 V 0 A 1 A 1.2 A 150 mV 3% 4 -15 V 0 A 1 A 1.2 A 150 mV 3% GPC55F GPM55F 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +12 V 0 A 3 A 5 A 120 mV 2% 3 +15 V 0 A 1 A 1.2 A 150 mV 3% 4 -15 V 0 A 1 A 11 150 mV 3% GPC55-5 GPM55-5 1 5 V 0 A 11 A 14 A 50 mV 2% GPC55-12 GPM55-12 1 12 V 0 A 4.7 A 5.8 A 120 mV 2% GPC55-15 GPM55-15 1 15 V 0 A 3.7 A 4.7 A 150 mV 2% GPC55-24 GPM55-24 1 24 V 0 A 2.3 A 2.9 A 240 mV 2% GPC55-28 GPM55-28 1 28 V 0 A 2.0 A 2.4 A 280 mV 2% GPC55-48 1 48 V 0 A 1.5 A 1.5 A 480 mV 2% A. Total regulation is denfi ed as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Add G suxffi to model to indicate RoHS compliant moel. GPC55/GPM55 MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING A. Units should be allowed to warm up/operate under non-condensing Temperature (A) See individual Specs -40 to +85C conditions before application of power. Humidity (A) 0 to 95% RH 0 to 95% RH B. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 Shock (B) 20 g 40 g orthogonal axes, total 6 shocks. pk pk Altitude -500 to 10,000 ft -500 to 40,000 ft C. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 2 2 Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz rms rms hr./axis non-operating. SL Power Electronics Corp.. 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 5/08. Data Sheet 2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.