GPFM115 Medical 115 Watt Global Performance Switchers GLOBAL PERFORMANCE SWITCHERS FEATURES: D C P o w e r S u p p l i e s 115 Watts of continuous power with forced air Power factor corrected 74-81% efficiency Small package 3.3 x 5.25 x 1.5 inches Power fail warning, remote sense Optional cover with cooling fan Medical Approval to UL2601-1, CSA-C22.2 No. 601.1, EN60601-1 RoHS Compliant Model Available (G suffix) SPECIFICATIONS Ac Input Transient Response 85-264 Vac, 47-63 Hz single phase Main Output 500 s typical response time for return to within 0.5% of final value for a 50% load step change, i/t<0.2 A/s. Maximum voltage deviation is 3.5%. Output Power Continuous rating is 80 W with unrestricted natural convection, or 115 W with Minimum Load forced convection. All models capable of 110% of rated power for 60 sec., No minimum load required to maintain output specifications. An abrupt change in 10% duty cycle maximum. output current from > 90% to < 2% load may cause a false triggering of the power fail signal. Input Current Maximum input current at 90 Vac, 60 Hz with full rated load is 1.7 A. Input Voltage Adjustment current harmonic content meets the requirements of IEC1000-3-2 for all load Main output 5%. conditions at 230 Vac input. Active input circuitry provides high power factor Temperature Coefficient of .96 min, .99 typical. 0.03%/C typical on all outputs. Inrush Current Thermal Shutdown Inrush 240 Vac is less than 37 A, averaged over thr first ac halfcycle under cold Provided as a standard feature. Designed to protect unit from prolonged over start conditions. Limiting provided by internal thermistors. temperature. Holdup Time Fan Output 25 ms minimum from loss of ac input at full load. An additional 12 Vdc (nominal 10.5 V), 100 mA output suitable for powering a dc Power Fail fan is included in all models. The fan output is referenced to +out. Due to high TTL / CMOS compatible output goes low (<0.5 V) 8 ms before output voltage pk-pk noise and low regulation, it is not recommended that this output be used drops more than 4% below nominal voltage upon loss of ac power. The signal is for any other purpose. factory set to trip before there is insucffi ient power stored in the primary to sus - Input Protection tain the output. Signal can sink 1.6 mA or source 400 A at 2.7 V (Fan-out = 1). Internal ac fuse provided on all models. Fuse does not blow on overload or short Efficiency circuit -- fuse blows only if a catastrophic failure occurs in the unit. 74 to 81% depending upon model EMI/EMC Compliance DC Output Specification All models include built-in EMI filtering to meet the following emissions require - Total regulation is the maximum deviation from the nominal voltage for all ments: steady state loading conditions. Peak ratings are for 60 s maximum duration, EMI SPECIFICATIONS COMPLIANCE LEVEL 10% duty cycle. Consult factory for application assistance. Conducted Emissions EN55011 Class B FCC Class B Remote Sense Static Discharge EN61000-4-2, 6 kV contact, 8 kV air Provided as a standard feature on all models. Capable of compensating for RF Field Susceptibility EN61000-4-3, 3 V/meter 0.25 V total of cabling losses. Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Overload Protection Line Frequency Harmonics EN61000-3-2 Class A Fully protected against short circuit and output overload. Short circuit protec- Conducted RF Susceptibility EN61000-4-6, 3 V tion is cycling type power limit. Recovery after fault is automatic. Consult Voltage Dips and Interruptions EN61000-4-11, Consult factory for more factory for specific condition limits. details. Overvoltage Protection Built in on all models - See voltage and current chart for individual model Leakage Current 90 A normal conditions (132 Vac 60 Hz input) or 250 A (264 Vac) single fault. output limits. When OVP fires, the output converter stops providing input power to output. Output voltage decay is dependent upon loading. Medical Safety Output Noise All models are Certified to be in compliance with the applicable requirements of UL 2601, CSA 22.2 No. 601.1-M90, IEC 601-1 (1988), EN 60601-1: 1990. (Consult 0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. factory for approval status) O All specifications are typical at nominal input, full load at 25 C unless otherwise statedMedical RoHS Voltage Output Ad- Output Maximum (B) Output Peak Total OVP Ripple/ Notes Model Suffix* Output justment Maximum (A) Regulation Setpoint Noise GPFM115-5 G 5.1 V 5% 12 A 20 A 25 A 2% 6.2 0.6 V 1% C GPFM115-12 G 12 V 5% 6.7 A 9.6 A 10.8 A 2% 14 1.1 V 1% C GPFM115-13 G 13 V 5% 6.2 A 8.8 A 9.9 A 2% 15 1.1 V 1% C GPFM115-15 G 15 V 5% 5.3 A 7.7 A 8.7 A 2% 18.5 1.5 V 1% C GPFM115-24 G 24 V 5% 3.3 A 4.8 A 5.4 A 2% 28 2.5 V 1% C GPFM115-28 G 28 V 5% 2.9 A 4.1 A 4.6 A 2% 34 2.8 V 1% C GPFM115-48 G 48 V 5% 1.7 A 2.4 A 2.7A 2% 55 4.0 V 1% C Notes: * Add G suffix to part number for RoHS compliant model. A. Maximum continuous current rating for unrestricted convection cooling. B. Maximum continuous current rating with 150 LFM air or cover option. C. Add -C after voltage in model number for cover with fan option. GPFM115 MECHANICAL SPECIFICATIONS JI INPUT: (AMP P.C.B. HEADER P.N 640445-5) PIN 1) AC LINE PIN 2) = N/C PIN 3) = AC NEUTRAL PIN 4) = N/C PIN 5) = AC GROUND SIGNALS: J2 AMP P.C.B. HEADER P/N 640456-4 MATING CONNECTOR P/N 640621-4 PIN 1) POWER FAIL PIN 2) -SENSE PIN 3) +SENSE PIN 4) COMMON FAN: J4 AMP P.C.B. HEADER P/N 640456-2 MATING CONNECTOR P/N 640621-2 PIN 1) - PIN 2) + OUTPUT J3- 5A MAXIMUM CONTINUOUS CURRENT PER CONNECTOR PIN. AMP P.C.B. HEADER P/N 640445-8 PIN 1-4) +Vout PINS 5-8) RETURN OUTPUT-MATING CONNECTOR AMP P/N HOUSING 640250-8 CONTACT 770476-1 INPUT MATING CONNECTOR AMP P/N HOUSING 640250-5 CONTACT 770476-1 MAX. SCREW PROTRUSION THROUGH CHASSIS = 0.08 2 MM , CHASSIS THICKNESS = 0.080 2 MM OPTIONAL COVER/FAN ASSEMBLY AVAILABLE P/N 09-115CF A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derate output current and total ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING output power by 2.5% per C above 50C. For operation in a confined space, moving air may be required. Under all conditions, the cooling vs. Temperature (A) 0 to 50 -40 to +85C load profile should be such that chassis temperatures do not exceed 90C for extended periods. Humidity (A) 0 to 95% RH 0 to 95% RH B. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 Shock (B) 20 g 40 g pk pk orthogonal axes, total 6 shocks. Altitude -500 to 10,000 ft -500 to 40,000 ft C. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2 2 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz rms rms hr./axis non-operating. SL Power Electronics, Inc. 6050 King Drive, Bldg. A, Ventura, CA, 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info slpower.com www.slpower.com Rev. 5/6/08. Data Sheet 2008 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.