GPC140 Commercial/GPM140 Medical
140 Watt Global Performance Switchers
FEATURES:
Wide-range ac input 85-264 Vac
2-year warranty
Conducted EMI exceeds FCC Class B and CISPR 22
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
Single outputs
Commercial Approved to UL1950, IEC950,
EN60950 and CSA22.2-234 L3
Medical Approved to UL2601-1, IEC601-1 and
CSA22.2 No. 601
marked to LVD
SPECIFICATIONS:
Ac Input Output Noise
85-264 Vac, 47-63 Hz single phase. 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
mode. Measured with noise probe directly across output
Input Current terminals of the power supply.
Maximum input current at 120 Vac, 60 Hz with full rated
output load: 3.7 A Transient Response
Main output500 s typical response time for return to
Hold-Up Time within 0.5% of final value for a 50% load step change. i/
20ms minimum from loss of ac input at full load, nominal t<0.2 A/s. Maximum voltage deviation is 3.5%. Startup/
shutdown overshoot less than 3%.
line (115 Vac).
Output Power Remote Sense
140 W convection; 160 W with air flow. Peak ratings are Provided as a standard feature.
for 60 s maximum duration, 10% duty cycle.
Voltage Adjustment
Overload Protection Built-in potentiometer adjusts voltage 5%.
Fully protected against short circuit and output overload.
Short circuit protection is cycling type power limit on Overload Protection
output 1. Recovery after fault is automatic. Factory set to begin power limiting at approximately 175 W.
Overvoltage Protection EMI/EMC Compliance
Main outputs: 130% 15% typical. All models include built-in EMI filtering to meet the
following emissions requirements:
Efficiency EMI SPECIFICATIONS COMPLIANCE LEVEL
70% at full rated load, nominal input voltage, depending Conducted Emissions GPC140 EN55022 Class B; FCC Class B
on model and load distribution. Conducted Emissions GPM140 EN55011 Class B; FCC Class B
Static Discharge EN61000-4-2, 6 kV contact, 8 kV air
Input Protection RF Field Susceptibility EN61000-4-3, 3 V/meter
Internal ac fuse provided. Designed to blow only if a Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz
catastrophic failure occurs in the unit. Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com.
Inrush Current Commercial Leakage Current
Inrush is limited by internal thermistors. Inrush at 240 Vac, 0.95 mA 254 Vac @ 60 Hz input.
averaged over the first ac half-cycle under cold start
conditions will not exceed 60 A. Commercial Safety
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950
Temperature Coefficient and EN60950. UL file #E135803 commercial; CSA
#LR46516 all models. The output(s) are intended for
0.03%/C typical on all outputs.
safety earthed Signal Output and Intermediate Circuits
only. All dc outputs are SELV under normal and single
Thermal Shutdown
fault conditions.
Provided as a standard feature. Designed to protect unit
from prolonged overtemperature.
Medical Leakage Current
60 A 254 Vac @ 60 Hz input.
Environmental
Designed for 0 to 50C operation at full rated output
Medical Safety
power; derate output current and total output power by
Approved to UL2601, CSA22.2 No. 601 Level 3 and
2.5% per C above 50C. See Environmental and
IEC601. UL file E116994; CSA #LR46516. The output(s)
Packaging Specifications on next page.
are intended for safety earthed Signal Output and
Intermediate Circuits only. The output(s) are not accept-
Power Fail
able for patient connection without additional isolation. All
TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms
dc outputs are SELV under normal and single fault
before output voltage drops more than 4% below
conditions.
nominal voltage upon loss of ac power. The signal is
factory set to trip on 84 to 94 Vac brown-out depending
upon incoming line impedance and distortion. Other
settings are available to the user through adjustment of
built-in potentiometer.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com
56GPC140 Commercial/GPM140 Medical 140 Watt Multiple Output
Commercial Medical Output Output Output
Model Model Output Minimum Maximum (B) Maximum (C) Peak Noise P-P Total Regulation (A)
GPC140-5 GPM140-5 5AV 0A2A6 3A0 3V25%0 m 2
GPC140-12 GPM140-121A2 V 0A1A1.7 1A3.4 1V4.61%20 m 2
GPC140-15 GPM140-151A5 V 0A9A.3 1A0.7 1V1.71%50 m 2
GPC140-24 GPM140-242A4 V 0A5A.8 6A.7 7V.32%40 m 2
GPC140-28 GPM140-282A8 V 0A5A5A.7 6V.32%80 m 2
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. Unrestricted natural convection cooling.
C. Requires 26cfm moving air.
GPC140/GPM140 MECHANICAL SPECIFICATIONS
Environmental
Operating Non-operating
Specification
o
Tsemperature (A)S5ee individual spec -40 to +8 C
HHumidity (A)0Hto 95% R 0 to 95% R
A. Units should be allowed to warm up/operate under non-condensing conditions
Sghock (B) 20 40 g
pk pk before application of power.
B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
Atltitude-t500 to 10,000 f -500 to 40,000 f
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
2 2 C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes,
Vgibration (C) 1.5 , 0.003 g/gHz 5 , 0.026 g /Hz
rms rms
total 6 shocks.