GPC130 Commercial/GPM130 Medical 130 Watt Global Performance Switchers FEATURES: Wide-range ac input 85-264 Vac 2-year warranty Commercial Approved to UL1950, IEC950, EN60950 and CSA22.2-234 L3 Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601 Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) marked to LVD Power Fail SPECIFICATIONS: TTL- or CMOS-compatible output goes low (< 0.5V) 5 ms Ac Input before output voltage drops more than 4% below nominal 85-264 Vac, 47-63 Hz single phase. voltage upon loss of ac power. The signal is factory set to trip on 84 to 94Vac brown-out depending upon incoming line Input Current impedance and distortion. Other settings are available to the Maximum input current at 120 Vac, 60 Hz with full rated output user through adjustment of built-in potentiometer. load: 3.5 A Output Noise Hold-Up Time 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. 20 ms minimum from loss of ac input at full load, nominal line Measured with noise probe directly across output terminals of (115 Vac). the power supply. Output Power Transient Response 100 W continuous, 165 W peak 130 W with 26 cfm air flow. Peak Main output500Sec typical response time for return to within ratings are for 60 s maximum duration, 10% duty cycle. During 0.5% of final value for a 50% load step change. i/ t<0.2 A/s. peak load condition, output regulation may exceed total Maximum voltage deviation is 3.5%. Startup/shutdown overshoot regulation limits. less than 3%. Overload Protection Remote Sense Fully protected against short circuit and output overload. Short Provided as a standard feature on output 1. circuit protection is cycling type power limit on outputs 1 & 2 foldback type on outputs 3 & 4. Recovery after fault is automatic. Voltage Adjustment See output ratings chart for additional notes or conditions. Built-in potentiometer adjusts voltage 5% on outputs 1 & 2. Overvoltage Protection Overload Protection Main outputs: 124% 12% typical. Factory set to begin power limiting at approximately 170 W. Efficiency EMI/EMC Compliance 70% at full rated load, nominal input voltage, depending on model All models include built-in EMI filtering to meet the following and load distribution. emissions requirements: EMI SPECIFICATIONS COMPLIANCE LEVEL Turn-on Time Conducted Emissions GPC130 EN55022 Class B FCC Class B Less than 1 second at 120 Vac, 25C (inversely proportional to Conducted Emissions GPM130 EN55022 Class B FCC Class B input voltage and thermistor temperature). Static Discharge EN61000-4-2, 6 kV contact, 8 kV air RF Field Susceptibility EN61000-4-3, 3 V/meter Input Protection Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Internal ac fuse provided. Designed to blow only if a catastrophic Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. failure occurs in the unit. Commercial Leakage Current Inrush Current 0.7 mA 254 Vac 60 Hz input. Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start conditions will not exceed 34 A. Commercial Safety Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and Temperature Coefficient EN60950. UL file E135803 commercial CSA LR46516 all models. The output(s) are intended for safety earthed Signal 0.03%/C typical on all outputs. Output and Intermediate Circuits only. All dc outputs are SELV under normal and single fault conditions. Thermal Shutdown Provided as a standard feature. Designed to protect unit from Medical Leakage Current prolonged overtemperature. 35 A 254 Vac 60 Hz input. Environmental Medical Safety Designed for 0 to 50C operation at full rated output power Approved to UL2601, CSA22.2 No. 601 Level 3 and IEC601. UL derate output current and total output power by 2.5% per C file E116994 CSA LR46516. The output(s) are intended for above 50C. See Environmental and Packaging Specifications safety earthed Signal Output and Intermediate Circuits only. The on next page. output(s) are not acceptable for patient connection without additional isolation. All dc outputs are SELV under normal and single fault conditions. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 54GPC130 Commercial/GPM130 Medical 130 Watt Multiple Output Commercial Medical Output Output Output Total Model Model Output No. Output Minimum Maximum (B) Maximum (C) Output Peak Noise P-P Regulation (A) GPC130A GPM130A 1 +5 V 3 A 16 A 20 A 25 A 50 mV 2% 2 +12 V 0 A 5 A 5 A 8 A 120 mV 2% 3 -12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3% 4 +12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3% GPC130B GPM130B 1 + 5 V 3 A 16 A 20 A 25 A 50 mV 2% 2 +12 V 0 A 5 A 5 A 8 A 120 mV 2% 3 -5 V 0 A 1.2 A 1.2 A 1.5 A 50 mV 3% 4 -12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3% GPC130C GPM130C 1 +5 V 3 A 16 A 20 A 25 A 50 mV 2% 2 +12 V 0 A 5 A 5 A 8 A 120 mV 2% 3 -15 V 0 A 1.2 A 1.2 A 1.5 A 150 mV 3% 4 +15 V 0 A 1.2 A 1.2 A 1.5 A 150 mV 3% GPC130D GPM130D 1 +5 V 3 A 16 A 20 A 25 A 50 mV 2% 2 +24 V 0 A 3.5 A 3.5 A 5 A 240 mV 2% 3 -12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3% 4 +12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3% GPC130E GPM130E 1 +5 V 3 A 16 A 20 A 25 A 50 mV 2% 2 +24 V 0 A 3.5 A 3.5 A 5 A 240 mV 2% 3 -15 V 0 A 1.2 A 1.2 A 1.5 A 150 mV 3% 4 +15 V 0 A 1.2 A 1.2 A 1.5 A 150 mV 3% A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Unrestricted natural convection cooling. C. Requires 26 cfm moving air. GPC130/GPM130 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o Tsemperature (A)S5ee individual spec -40 to +8 C HHumidity (A)0Hto 95% R 0 to 95% R A. Units should be allowed to warm up/operate under non-condensing conditions Sghock (B) 20 40 g pk pk before application of power. B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 Atltitude-t500 to 10,000 f -500 to 40,000 f orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes, 2 2 Vgibration (C) 1.5 , 0.003 g/gHz 5 , 0.026 g /Hz rms rms total 6 shocks. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 55