GPC200 Commercial/GPM200 Medical 200 Watt Global Performance Switchers FEATURES: Wide-range ac input 85-264 Vac 2-year warranty Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Commercial Approved to UL1950, IEC950 and CSA22.2-234 L3 Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601 Multiple outputs marked to LVD Power Fail SPECIFICATIONS: TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms Ac Input before output voltage drops more than 4% below nominal voltage upon loss of ac power. The signal is factory set to trip on 85-264 Vac, 47-63 Hz single phase. 84 to 94 Vac brown-out depending upon incoming line impedance and distortion. Other settings are available to the user through Input Current adjustment of built-in potentiometer. Maximum input current at 120 Vac, 60 Hz with full rated output load: 5.5 A Output Noise Hold-Up Time 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. 20 ms minimum from loss of ac input at full load, nominal line Measured with noise probe directly across output terminals of (115 Vac). the power supply. Output Power Transient Response 150 W convection 200 with 26 cfm air 220 W peak. Peak ratings Main output500 s typical response time for return to within are for 60 s maximum duration, 10% duty cycle. During peak 0.5% of final value for a 50% load step change. i/ t<0.2 A/s. load condition, output regulation may exceed total regulation Maximum voltage deviation is 3.5%. Startup/shutdown overshoot limits. less than 3%. Overload Protection Remote Sense Fully protected against short circuit and output overload. Short Provided as a standard feature on main 5 V output. circuit protection is cycling type power limit on outputs 1 & 2 foldback type on outputs 3 & 4. Recovery after fault is automatic. Voltage Adjustment See output ratings chart for additional notes or conditions. Built-in potentiometer adjusts voltage 5% on output 1 & 2. Overvoltage Protection EMI/EMC Compliance Main outputs: 124% 12% typical. All models include built-in EMI filtering to meet the following emissions requirements: Efficiency EMI SPECIFICATIONS COMPLIANCE LEVEL Minimum 65% at full rated load, nominal input voltage, depending Conducted Emissions GPC200 EN55022 Class B FCC Class B on model and load distribution. Conducted Emissions GPM200 EN55011 Class B FCC Class B Static Discharge EN61000-4-2, 6 kV contact, 8 kV air Input Protection RF Field Susceptibility EN61000-4-3, 3 V/meter Internal ac fuse provided. Designed to blow only if a catastrophic Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz failure occurs in the unit. Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Inrush Current Commercial Leakage Current Inrush is limited by internal thermistors. Inrush at 240 Vac under 0.95 mA 254 Vac 60 Hz input (with no deviations). cold start conditions will not exceed 60 A. Commercial Safety Temperature Coefficient Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. UL file E135803 commercial CSA LR46516 all 0.03%/C typical on all outputs. models. The output(s) are intended for safety earthed Signal Output and Intermediate Circuits only. All dc outputs are SELV Thermal Shutdown under normal and single fault conditions. Provided as a standard feature. Designed to protect unit from prolonged overtemperature. Medical Leakage Current 60 A 254 Vac 60 Hz input. Environmental Designed for 0 to 50C operation at full rated output power Medical Safety derate output current and total output power by 2.5% per C Approved to UL2601-1, CSA-C22.2 No. 601 Level 3 and IEC601. above 50C. See Environmental and Packaging Specifications UL file E116994 CSA LR46516. The output(s) are intended for on next page. safety earthed Signal Output and Intermediate Circuits only. The output(s) are not acceptable for patient connection without additional isolation. All dc outputs are SELV under normal and single fault conditions. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 64GPC200 Commercial/GPM200 Medical 200 Watt Multiple Output Commercial Medical Output Output Output Total Output No. Output Output Peak Noise P-P Model Model Minimum Maximum (B) Maximum (C) Regulation (A) GPC200A GPM200A 1 +5 V 4 A 18 A 26 A 32 A 50 mV 2% 2 +12 V 0 A 5 A 8 A 12 A 120 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.5 A 120 mV 3% 4 12 V (D) 0 A 3 A 4 A 4.5 A 120 mV 3% GPC200B GPM200B 1 + 5 V 4 A 18 A 26 A 32 A 50 mV 2% 2 +12 V 0 A 5 A 8 A 12 A 120 mV 2% 3 -5 V 0 A 1 A 1.2 A 1.5 A 50 mV 3% 4 12 V (D) 0 A 3 A 4 A 4.5 A 120 mV 3% GPC200D GPM200D 1 +5 V 4 A 18 A 26 A 32 A 50 mV 2% 2 +24 V 0 A 3 A 5 A 6.5 A 240 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.5 A 120 mV 3% 4 12 V (D) 0 A 3 A 4 A 4.5 A 120 mV 3% GPC200E GPM200E 1 +5 V 4 A 18 A 26 A 32 A 50 mV 2% 2 +24 V 0 A 3 A 5 A 6.5 A 240 mV 2% 3 -15 V 0 A 1 A 1.2 A 1.5 A 150 mV 3% 4 15 V (D) 0 A 3 A 4 A 4.5 A 150 mV 3% GPC200F GPM200F 1 +5 V 4 A 18 A 26 A 32 A 50 mV 2% 2 +12 V 0 A 5 A 8 A 12 A 120 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.5 A 120 mV 3% 4 5 V (D) 0 A 3 A 4 A 4.5 A 50 mV 3% A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Ratings for unrestricted natural convection cooling outputs 1 & 2 combined load not to exceed 22A continuous total power -150W. C. Ratings with 26cfm forced air cooling outputs 1 & 2 combined load not to exceed 32A continuous total power -200W. D. Isolated output which may be referenced as a positive or negative voltage. GPC200/GPM200 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o Tsemperature (A)S5ee individual spec -40 to +8 C A. Units should be allowed to warm up/operate under non-condensing conditions HHumidity (A)0Hto 95% R 0 to 95% R before application of power. B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 Sghock (B) 20 40 g pk pk orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. Atltitude-t500 to 10,000 f -500 to 40,000 f C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes, total 6 shocks. 2 2 Vgibration (C) 1.5 , 0.003 g/gHz 5 , 0.026 g /Hz rms rms Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 65