GPC225 Commercial/GPM225 Medical 225 Watt Global Performance Switchers FEATURES: Wide-range ac input 85-264 Vac 2-year warranty Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Commercial Approved to UL1950, IEC950 and CSA22.2-234 L3 Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601 marked to LVD SPECIFICATIONS: Ac Input 85-264 Vac, 47-63 Hz single phase. line impedance and distortion. Other settings are avail- able to the user through adjustment of built-in potentiometer. Input Current Maximum input current at 120 Vac, 60 Hz with full rated Output Noise output load: 5.5 A 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output Hold-Up Time terminals of the power supply. 20 ms minimum from loss of ac input at full load, nominal line (115 Vac). Transient Response 500 s typical response time for return to within 0.5% of Output Power final value for a 50% load step change. i/ t<0.2 A/s. 175 W convection 225 W with 26 cfm air 250 W peak. Peak Maximum voltage deviation is 3.5%. Startup/shutdown ratings are for 60 s maximum duration, 10% duty cycle. overshoot less than 3%. Overload Protection Remote Sense Fully protected against short circuit and output overload. Provided as a standard feature. Short circuit protection is cycling type power limit. Recovery after fault is automatic. Factory set to begin Voltage Adjustment power limiting at approximately 250 W. Built-in potentiometer adjusts voltage 5%. Overvoltage Protection EMI/EMC Compliance 124% 12% typical. All models include built-in EMI filtering to meet the following emissions requirements: Efficiency EMI SPECIFICATIONS COMPLIANCE LEVEL 70% at full rated load, nominal input voltage, depending Conducted Emissions GPC225 EN55022 Class B FCC Class B on model and load distribution. Conducted Emissions GPM225 EN55011 Class B FCC Class B Static Discharge EN61000-4-2, 6 kV contact, 8 kV air Input Protection RF Field Susceptibility EN61000-4-3, 3 V/meter Internal ac fuse provided. Designed to blow only if a Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz catastrophic failure occurs in the unit. Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Inrush Current Commercial Leakage Current Inrush is limited by internal thermistors. Inrush at 240 Vac 0.95 mA 254 Vac 60 Hz input (with no deviations). under cold start conditions will not exceed 60 A. Commercial Safety Temperature Coefficient Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950, 0.03%/C typical on all outputs. EN60950 and CISPR22. UL file E135803 commercial CSA LR46516. The output(s) are intended for safety Thermal Shutdown earthed Signal Output and Intermediate Circuits only. All Provided as a standard feature. Designed to protect unit dc outputs are SELV under normal and single fault from prolonged over temperature. conditions. Environmental Medical Leakage Current Designed for 0 to 50C operation at full rated output 60 A. 254 Vac 60Hz input. power derate output current and total output power by 2.5% per C above 50C. See Environmental and Medical Safety Packaging Specifications on next page. Approved to UL2601, CSA22.2 No. 601 Level 3 and IEC601. UL file E116994 CSA LR46516. The output(s) Power Fail are intended for safety earthed Signal Output and TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms Intermediate Circuits only. The output(s) are not accept- before output voltage drops more than 4% below nominal able for patient connection without additional isolation. All voltage upon loss of ac power. The signal is factory set to dc outputs are SELV under normal and single fault trip on 84 to 94 Vac brown-out depending upon incoming conditions. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 66GPC225 Commercial/GPM225 Medical 225 Watt Multiple Output Commercial Medical Output Output Output Model Model Output Minimum Maximum (B) Maximum (C) Peak Noise P-P Total Regulation (A) GPC225-5 GPM225-5 5AV 0A3A4 4A0 4V5 5%0 m 2 GPC225-12 GPM225-121A2 V 0A1A5.8 1A9 2V0 1%20 m 2 GPC225-15 GPM225-151A5 V 0A1A2.7 1A5 1V6 1%50 m 2 GPC225-24 GPM225-242A4 V 0A8A.3 9A.4 1V0 2%40 m 2 GPC225-28 GPM225-282A8 V 0A7A.1 8A8V.5 2%80 m 2 A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Unrestricted natural convection cooling. C. Requires 26cfm moving air. GPC225/GPM225 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o Tsemperature (A)S5ee individual spec -40 to +8 C HHumidity (A)0Hto 95% R 0 to 95% R A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Sghock (B) 20 40 g pk pk B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 Atltitude-t500 to 10,000 f -500 to 40,000 f orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes, 2 2 Vgibration (C) 1.5 , 0.003 g/gHz 5 , 0.026 g /Hz total 6 shocks. rms rms Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 67