GPFC125 Commercial/GPFM125 Medical
125 Watt Global Performance Switchers
FEATURES:
Compact 125 watt multiple output
Power density of 4 watts per cubic inch
Power Factor Correction to meet EN61000-3-2
Small package 6.00 x 3.5 x 1.5 inches
Conducted EMI exceeds FCC Class B and CISPR 22
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
Commercial approved to UL1950, IEC950, CSA22.2
No. 950 and EN60950.
Medical approved to UL2601-1, IEC601-1, CSA22.2
No. 601.1, EN60601-1
marked to LVD
SPECIFICATIONS:
Ac Input Remote Sense
90-264 Vac, 47-63 Hz single phase. Provided as a standard feature on V1 of all models.
Input Current Temperature Range
Maximum input current 2A at 90 Vac, 60 Hz with full rated load. 0 to 50 C at full rated output power. For operation above 50 C,
Input current harmonic content meets the requirements of derate output power and current by 2.5 % per C.
IEC1000-3-2. Active circuitry provides high power factor as
Altitude
listed at .96 min., .99 typical. All data taken with full output
Operating: -500 to 10,000 ft. MSL
loading.
Non-Operating -500 to 40,000 ft MSL
DC Output Power
Shock and Vibration
125 W with 150 LFM of air, 50 W convection cooled, 80 W
All models are designed to meet the following specifications;
convection cooled with unit mounted to min. 12 x 12 x .125 in.
Random Vibration -
thick aluminim plate. Peak ratings are for 60 s maximum
2
duration, 10% duty cycle. With optional cover installed,125 W, Operating: 0.003 g /Hz, 1.5 g overall, 3 axes, 10 min. / axis
rms
2
200 LFM airflow is required(-C suffix).
Non-Operating: 0.026 g /Hz, 5.0 g overall, 3 axes, 1 hr. / axis
rms
Inrush Current
Shock -
Inrush 240 Vac is less than 37 A, averaged over the first ac
Operating: Half-sine, 20 g , 10 ms, 3 axes, 6 shocks total
pk
half-cycle under cold start conditions. Limiting provided by
Non-Operating: Half-sine, 40 g , 10 ms, 3 axes, 6 shocks total
internal thermistors. pk
Input Protection
EMI/EMC Compliance
Internal ac fuse provided on all models. Fuse does not blow on
All models include built-in EMI filtering to meet the EMC
overload or short circuit fuse blows only if a catastrophic
requirements below.
failure occurs in the unit.
EMI SPECIFICATIONS COMPLIANCE LEVEL
Efficiency
Conducted Emissions-GPFC125 EN55022, Class B; FCC Class B
72 to 85% at full rated load. Depending upon model and load
Conducted Emissions-GPFM125 EN55011,Class B; FCC Class B
distribution.
Static Discharge EN61000-4-2, 6 kV contact 8 kV air
Minimum Load
RF Field Susceptibility EN61000-4-3, 3V/meter
Supply will function with no load on any output. To maintain
Fast Transients / Bursts EN61000-4-4, 2 kV, 5 kHz
regulation with full load on V2, 3 and 4 output V1 requires a
Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com.
minimum load of (2A + V4 current). Lower minimum load may be
Conducted RF Susceptibility EN61000-4-6, 3V
obtained if less then full load is drawn from auxiliary outputs.
Voltage Sags & Surges EN61000-4-11
Line Frequency Harmonics EN61000-3-2 Class A
Overload Protection
Fully protected against short circuit and output overload. Total
Commercial Safety Approvals
output power limited to approximately 150 Watts. Cycling type
All models are approved to UL1950, CSA22.2 No. 950-95,
limits on output 1, 2 & 3, linear fold back on output 4. Recovery
IEC950, EN60950. CB certificate available. Exceeds FCC and
after fault is automatic.
CISPR22 Class B conducted emissions requirement
Overvoltage Protection
Medical Safety Approvals
Built in on all models - See Output table for individual model
All models are Certified to be in compliance with the applicable
output limits.
requirements of UL2601, CSA 22.2 No. 601.1-M90, IEC 601-1
Output Noise
(1988), EN 60601-1: 1990. CB certificate available.
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode.
Leakage Current
Transient Response
The maximum leakage current is as follows:
500 ms typical response time for return to within 0.5% of final
value for a 50% load step change, i/ t< 0.2 A ms. Maximum Test Condition Normal Single Fault
voltage deviation is 3.5%.
132 Vac @ 60 Hz input 70 A 120 A
Temperature Coefficient
264 Vac @ 50 Hz input 130 A 240 A
0.03% / C typical on all outputs.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com
52GPFC125 Commercial/GPFM125 Medical 125 Watt Multiple Output
Commercial Medical Voltage Output Voltage Output Qutput Voltage OVP Total Ripple/
Model Model Output No. Current (A) Current (B) Adjustment Regulation Noise
GPFC125A GPFM125A 1 +5 V 9 A 16 A 5% 6.2 0.6 V 1% 1%
2 +12 V 4 A 7 A 5% -- 1% 1%
312 V (C) 2.5 A 4 A -- -- 1% 1%
4-12 V 0.3 A 1 A -- -- 1% 1%
GPFC125B GPFM125B 1 +5 V 9 A 16 A 5% 6.2 0.6 V 1% 1%
2 +12 V 4 A 7 A 5% -- 1% 1%
312 V (C) 2.5 A 4 A -- -- 1% 1%
4-5 V 0.3 A 1 A -- -- 1% 1%
GPFC125C GPFM125C 1 +5 V 9 A 16 A 5% 6.2 0.6 V 1% 1%
2 +12 V 4 A 7 A 5% -- 1% 1%
315 V (C) 2.5 A 4 A -- -- 1% 1%
4-15 V 0.3 A 1 A -- -- 1% 1%
GPFC125D GPFM125D 1 +5 V 9 A 16 A 5% 6.2 0.6 V 1% 1%
2 +24 V 3 A 4.5 A 5% -- 1% 1%
312 V (C) 2.5 A 4 A -- -- 1% 1%
4-12 V 0.3 A 1 A -- -- 1% 1%
GPFC125E GPFM125E 1 +5 V 9 A 16 A 5% 6.2 0.6 V 1% 1%
2 +24 V 3 A 4.5 A 5% -- 1% 1%
315 V (C) 2.5 A 4 A -- -- 1% 1%
4-15 V 0.3 A 1 A -- -- 1% 1%
GPFC125F GPFM125F 1 +5 V 9 A 16 A 5% 6.2 0.6 V 1% 1%
2 +15 V 3.5 A 6 A 5% -- 1% 1%
315 V (C) 2.5 A 4 A -- -- 1% 1%
4 - 5 V 0.3 A 1 A -- -- 1% 1%
9 A
GPFC125G GPFM125G 1+5 V 16 A 5% 6.2 0.6 V 1% 1%
2 +3.3 V 7 A 10 A 5% 4.2 0.6 V 1% 2%
312 V (C) 2.5 A 4 A -- -- 1% 1%
4-12 V 0.3 A 1 A -- -- 1% 1%
GPFC125H GPFM125H 1 +3.3 V 9 A 16 A 5% 4.2 0.6 V 1% 2%
2 +5 V 4 A 7 A 5% 6.2 0.6 V 1% 1%
312 V (C) 2.5 A 4 A -- -- 1% 1%
4-12 V 0.3 A 1 A -- -- 1% 1%
Notes:
A. Continuous rating for unrestricted convection cooling.
B. Peak rating or continuous rating with 150 LFM air cooling.
C. Output 3 is isolated. Can be connected as + or - output.
GPFC125/GPFM125 MECHANICAL SPECIFICATIONS
INPUT: J1 AMP P.C.B. HEADER P/N 640445-5
PIN 1) AC LINE
PIN 2) N/C
PIN 3) AC NEUTRAL
PIN 4) N/C
PIN 5) AC GROUND
MATING CONNECTOR AMP P/N
HOUSING 640250-5
CONTACT 770476-1
SIGNALS: J2
AMP P.C.B. HEADER P/N 640456-4
MATING CONNECTOR P/N 640440-4
PIN 1) POWER FAIL
PIN 2) -SENSE
PIN 3) +SENSE
PIN 4) COMMON
OUTPUT: J3 AMP P.C.B HEADER P/N 1-640445-3
PIN 1) -V4OUT
PIN 2-4) +V1OUT
PINS 5-9) COMMON
PIN 10,11) +V2 OUT
PIN 12) +V3OUT
PIN 13) -V3RTN
MATING CONNECTOR AMP P/N
HOUSING 1-640250-3
CONTACT 770476-1
OPTIONAL COVER P/N 08-30466-2125
WEIGHT: 1.25 LBS [ .56 KG]
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com