GPFC160 Commercial
160 Watt Global Performance Switchers
FEATURES:
3.0 watts/cu.in. power density
Compact size (4.5" x 7.0" x 1.7"; meets 1U height)
Power factor corrected to IEC 1000-3-2; Class A
Less than 300 A leakage
EMI compliance to CISPR22, FCC Class B
Commercial Approved to UL1950, IEC950, EN60950
and CSA 22.2 No. 950
2-year warranty
marked to LVD
SPECIFICATIONS:
Ac Input
Input Protection
85-264 Vac, 47-63 Hz single phase. Internal ac fuse provided on all models. Fuse does not
blow on overload or short circuitfuse blows only if
Input Current catastrophic failure occurs in the unit.
Maximum input current 2.3 A at 90 Vac, 60 Hz with full
rated load. Input current harmonic content meets the Inrush Current
requirements of IEC1000-3-2. Inrush 240 Vac is less than 37 A, averaged over the first
ac half-cycle under cold start conditions. Limiting pro-
Hold-upTime
vided by internal thermistors.
25 ms minimum from loss of ac input at full load, nominal
line (115 Vac).
Fan Output
An additional 12 Vdc, 250 mA output suitable for power-
Output Power ing a dc fan is included in all models. The output is
Total regulation is the maximum deviation from the protected by an internal PTC in the event of an overload.
nominal voltage for all steady-state loading conditions.
Each individual output is to be used within its specified Thermal Shutdown
limits of that output. Peak ratings are for 60 s maximum Provided as a standard feature. Designed to protect the
duration, 10% duty cycle. unit from prolonged over temperature.
Overload Protection
Power Fail
Fully protected against short circuit and output overload.
TTL or CMOS compatible output goes low (<0.5 V) 8 ms
Short circuit protection is cycling type power limit.
before output voltage drops more than 4% below nominal
Recovery after fault is automatic. voltage upon loss of ac power. The signal is factory set to
trip when input power can no longer sustain the output.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential Temperature Coefficient
mode. Measured with noise probe directly across output 0.03%/C typical on all outputs.
terminals of the power supply.
EMI/EMC Compliance
Transient Response
All models include built-in EMI filtering to meet the
500 ms typical response time for return to within 0.5% of
following emissions requirements:
final value for a 50% load step change, i/ t< 0.2 A/ms.
EMI SPECIFICATIONS COMPLIANCE LEVEL
Maximum voltage deviation is 3.5%. Conducted Emissions EN55022 Class B; FCC Class B
Static Discharge EN61000-4-2, 6 kV contact, 8 kV air
Remote Sense RF Field Susceptibility EN61000-4-3, 3 V/meter
Provided as a standard feature. Capable of compensating Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz
for 0.25 V total of cabling losses. Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com.
Overvoltage Protection
Commercial Safety
Built in on all models. OVP crowbar reduces output
Approved to UL1950, CSA22.2 950, IEC950, and
voltage below nominal rating in less than 50 ms.
EN60950. UL file #E135803 commercial; CSA #LR46516.
The output(s) are intended for safety earthed Signal
Voltage Adjustment Output and Intermediate Circuits only. All dc outputs are
Main output 5%. SELV under normal and single fault conditions.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com
62GPFC160 Commercial 160 Watt Single Output
Output Output
Model Output No. Output Maximum (A) Peak (B) OVP Setpoint Ripple & Noise
GPFC160-5 1V5A.1 2A5 3V1.3 6%.2 0.6 1
GPFC160-12 1V1A2 1A1.7 1V3.3 1%4 1.1 1
GPFC160-15 1V1A5 9A.3 1V0.7 1%8.5 1.5 1
GPFC160-24 1V2A4 5A.8 6V.7 2%8 2.5 1
GPFC160-28 1V2A8 5A5V.7 3%4 2.8 1
GPFC160-48 1V4A8 2A.9 3V.4 5%5 4.0 1
A. Output rating with unrestricted convection cooling.
B. Output rating with 26 cfm airflow.
GPFC160 MECHANICAL SPECIFICATIONS
Environmental
Operating Non-operating
Specification
o o
T0emperature (A) 0 to 5C5-40 to +8 C
HHumidity (A)0Hto 95% R 0 to 95% R
A. Units should be allowed to warm up/operate under non-condensing conditions
before application of power. Derated output current and total output power by
Sghock (B) 20 40 g
pk pk
2.5% per 50C.
Atltitude-t500 to 10,000 f -500 to 40,000 f B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
2 2
Vgibration (C) 1.5 , 0.003 g/gHz 5 , 0.026 g /Hz
C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes,
rms rms
total 6 shocks.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com
63