100W Quad Output with PFC Function PPQ -100 series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 70KHz(Optional) 3 years warranty SPECIFICATION MODEL PPQ-100B PPQ-100C PPQ-100D OUTPUT NUMBER CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 12V -12V -5V 5V 15V -15V -5V 5V 24V 12V -12V RATED CURRENT 10A 3.4A 0.6A 0.6A 10A 2.6A 0.6A 0.6A 8A 2A 0.6A 0.6A CURRENT RANGE 2 ~ 15A 0.3 ~ 4A 0 ~ 1A 0 ~ 1A 2 ~ 15A 0.3 ~ 4A 0 ~ 1A 0 ~ 1A 2 ~ 10A 0.3 ~ 4A 0 ~ 1A 0 ~ 1A RATED POWER (max.) 101W 101W 102.4W RIPPLE & NOISE (max.) Note.2 100mVp-p 150mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p 100mVp-p 100mVp-p 200mVp-p 100mVp-p 100mVp-p OUTPUT VOLTAGE ADJ. RANGE CH1:4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 3.0% 8.0% 5.0% 5.0% 3.0% +10,-6% 5.0% 5.0% 3.0% 8.0% 5.0% 5.0% LINE REGULATION 1.0% 2.0% 2.0% 1.0% 1.0% 2.0% 2.0% 1.0% 1.0% 2.0% 2.0% 1.0% LOAD REGULATION 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% SETUP, RISE TIME 800ms, 50ms/230VAC 1200ms, 50ms/115VAC at full load HOLD UP TIME (Typ.) 24ms/230VAC 24ms/115VAC at full load VOLTAGE RANGE 90 ~ 264VAC 127 ~370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load EFFICIENCY(Typ.) 75% 76% 78% INPUT AC CURRENT (Typ.) 1.65A/115VAC 0.85A/230VAC INRUSH CURRENT (Typ.) COLD START 30A LEAKAGE CURRENT <3.5mA /240VAC 105% ~ 135% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION CH1: 5.75 ~ 6.75V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +60 (Refer toDerating Curv) WORKING TEMP. WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC (Note 4) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A MTBF 162.5K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 177.8*107.95*40mm (L*W*H) 0.62Kg 24pcs/15.9Kg/1.34CUFT PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on 100W Quad Output with PFC Function PPQ -100 series Mechanical Specification Unit:mm 177.8 165.1 6.35 CN3 1 AC Input Connector (CN1) : JST B5P-VH or equivalent 2 3 Pin No. Assignment Mating Housing Terminal 4 5 1 FG 6 7 2,4 No Pin JST VHR JST SVH-21T-P1.1 8 HS1 HS2 or equivalent or equivalent 1 3 AC/L 2 3 5 AC/N 4 5 FS1 DC Output Connector (CN2) : JST B5P-VH or equivalent CN2 AC FUSE T5A/250V Pin No. Assignment Mating Housing Terminal CN1 1,2 V2 LED 3 NC JST VHR JST SVH-21T-P1.1 FG 1 2 3 4 5 SVR1 or equivalent or equivalent 4 V3 4- 3.96 5 V4 DC Output Connector (CN3) : JST B8P-VH or equivalent Pin No. Assignment Mating Housing Terminal 1~4 V1 JST VHR JST SVH-21T-P1.1 or equivalent or equivalent 5~8 COM HS1,HS2 can not be shorted fosc : 70KHz (Option) Block Diagram RECTIFIERS V4 & REGULATOR FILTER EMI FILTER RECTIFIERS PFC POWER I/P & & REGULATOR V3 CIRCUIT SWITCHING FILTER RECTIFIERS RECTIFIERS V2 & PWM & PFC FILTER FG CONTROL RECTIFIERS +5V & COM FILTER DETECTION CIRCUT O.V.P. Derating Curve Output Derating VS Input Voltage 17.8CFM Forced Air Cooling(10cm) 100 100 90 90 80 80 70 60 60 40 50 20 40 -10 0 10 20 30 40 50 60 (HORIZONTAL) 90 100 115 135 155 230 264 -10 0 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:PPQ-100-SPEC 2012-02-21 LOAD (%) 3max. 40 95.25 6.35 LOAD (%) 107.95