60W Single Output MB60 Family Medical Grade FEATURES AND BENEFITS Medical Ultra Small Size of 2 x 3 x 1.063 Less than 0.5W no-load P ower Consumption For 1U Applications 3 Year Warranty 60W Conv ection Cooled Optional LED Indicat or for power-on Universal Input 90-264Vac RoHS Compliant rd Approved to IEC60601-1, 3 Edition with 2 MOPP Level V Efficiency Compliant Models Class II Input V ersions Available MODEL SELECTION Model Output Current Output Power * Volts Ripple & Noise Total Regulation OVP Threshold Number*** Convection Cooled Convection Cooled 4.58A MB60S12K 12V 55W 120mV pk-pk 2% 14.4-18Vdc 4.00A MB60S15K 15V 60W 150mV pk-pk 2% 18-22.5Vdc 3.33A MB60S18K 18V 60W 180mV pk-pk 2% 21-25.5Vdc 2.50A MB60S24K 24V 60W 240mV pk-pk 2% 28.8-36Vdc 1.67A MB60S36K** 36V 60W 360mV pk-pk 2% 42-47Vdc 1.25A MB60S48K 48V 60W 480mV pk-pk 2% 57.6-72Vdc Notes: 1. * At -20 C, the noise and ripple is 2% of the output. 2. ** For product availability, please contact the fact. ory. 3. ***Replace K in model number with C for class II input v ersions INPUT OUTPUT Output Power Input Voltage 90-264Vac, single phase 60W continuous for operation from -10C to 50C 55 Watts for 12V output. Input Current 120Vac: 1.4A, 240Vac: 0.75A Turn On Time <2 Seconds at 120Vac Inrush Current 40A maximum 0C 16mS minimum from loss of ac input at 120 Vac, full Input Fuses F1, F2: 2.5A, 250V ac Hold Up Time load Earth Leakage Current <275A 264Vac, 60 Hz input, NC / <90A 264Vac, Ripple and Noise 0.5% RMS, 1% pk-pk for all models 60 Hz input, NC Total Regulation 2% for all models Efficiency 83% to 88% 500s typ. response time for return to within 0.5% Transient Response Input Frequency 47-63Hz of final alue for a 50% load change, i/t< 0.2A/ s. Max. voltage deviation is 3.5% <0.5W No Load Input Power Minimum Load No minimum load is required Turn-on Input Voltage 70V 65V Turn-off Input Voltage MB60 Datasheet v0921 Copyright 2021 SL Power Electronics Corp. - All rights reserved. Page 1 60W Single Output MB60 Family Medical Grade RELIABILITY EMI/EMC COMPLIANCE MTBF 700,000 hours, 25C ambient, full load Conducted Emissions EN55011/22 Class B FCC Part 15 Warranty 3 Years Radiated Emissions EN55011/22 Class A FCC Part 15 HALT Data Per SL Power Halt procedure Voltage Fluctuations & EN61000-3-3 Flicker Static Discharge Immunity EN61000-4-2 6kV contact, 8kV air, Criteria A RF Field Susceptibility EN61000-4-3 (3V/m), Criteria A ISOLATION Fast Transients/Bursts EN61000-4-4 (PS: 2kV-40A, other lines 1kV-20A), Criteria B Isolation Safety Rating Input to Ground: 1 MOPP, Class I input models Input to Output: 2 MOPP Surge Susceptability EN61000-4-5, Installation Class 3 (1kV diff. Output to Ground: Functional, Class I input models mode, 2kV common mode), Criteria A Electric Strength Test Input to Ground: 1800Vac, Class I input models Conducted RF EN61000-4-6 (3Vrms), Criteria A Voltage Input to Output: 4000Vac Susceptability Output to Ground: 500Vac, Class I input models Power Frequency Magnetic EN61000-4-8 (3A/m), Criteria A Field Immunity Voltage Sags and Surges EN61000-4-11, SAFETY 95% dip/0.5 cycle (Criteria A), 60%/5cycles (Criteria B ), 30%/25 cycles rd (Criteria A) Safety Standards UL - ANSI/AAMI ES60101:2005, 3 Edition CSA - CAN/CSA-C22.2 No. 60601-1 (2008) Harmonic Current Emissions EN61000-3-2, Class A Demko - EN 60601-1:2006 rd CB Report - IEC 60601-1 (3 Edition) Notes: Isolation Type - B rated 1. Specifications subject o change without notice. 2. Specifications ae for convection rating at factory settings with 115Vac input and 25 C ambient unless otherwise stated. ENVIRONMENT Operating Temperature -10C to +80C PROTECTION Relative Humidity 5% to 95%, non-condensing Shock Non-Operating: Half-sine, 40 gpk, 10mS, 3 axes, 6 Overvoltage Protection OVP firing educes output voltage to <50% of shocks total nominal in <50mS. See chart for trip range For 24V output and up, derate output power to 50 Temperature Derating Short Circuit Protection Short across the output terminals will not cause Watts 60C, 40 Watt 70C, and 20 Watts for 80C damage to the unit. Hiccup Mode Altitude Operating: -500 to 3,000 meter Over temperature Pr otection Automatic Power Shutdown at Tc = 155C Non-operating: -500 to 40,000 ft. Overload Protection 120% - 180% of rated output current value, Storage Temperature -40C to +85C Hiccup Mode Vibration Random vibration per MIL-STD-810E, Method 514.4, Overshoot 5% overshoot at turn-on, 5% overshoot at turn- Cat. 1, Figure 514.4-1, 1 hr in each of three axes off, under all conditions Cooling Convection Notes: 1. <24V will derate to 40W at 60C, 30W at 70C, and 20 W at 80C MB60 Datasheet v0921 Copyright 2021 SL Power Electronics Corp. - All rights reserved. Page 2