Commercial/Medical International + Linears Medical Commercial FEATURES World-wide ac input ranges and safety standards Medical leakage current does not exceed 10 A Industry standard packages MTBF 200,000+ hours per Mil Handbk 217D (most units) Commercial UL/CSA TUV/IEC approved68 models to All electrolytic caps rated at 105C UL1950 CSA C22.2 No. 950 L3 TUV certified to EN60950 Transformer insulation meets Class F (155C) Burn-in with cycling 3-year warranty Exceed FCC and CISPR22, Class B conducted emissions Capacitors have highest CV & ripple current ratings marked to LVD Medical Approved to UL2601-1, IEC60601-1 and CSA601.1 SPECIFICATIONS: Ac Input Remote Sensing 100, 120 and 240 Vac: +10%, -13% 215 Vac: +12%, -11 Provided on all models open sense lead protection built-in % 47 to 63Hz. Tolerance for 230 Vac operation is +15%, (except HA series). -10%. Derate output current 10% for 50 Hz operation. Stability Dc Output 0.05% for 24 hours after warmup. See voltage rating chart. Adjustment range 5% minimum except HA series. Temperature Rating 0 to 50C full rated, derated linearly to 40% at 70C. Line Regulation 0.05% for a 10% change. Temperature Coefficient 0.01%/C maximum. Load Regulation 0.05% for a 50% load change. Efficiency 5 V units: 45% 12 and 15 V units: 55% 20 and 24 V units: 60%. Output Ripple 3 mV +0.05% of output voltage, peak to peak maximum. Logic Inhibit and Current-Share All 3-terminal regulator outputs: 3 mV +0.2% peak to F & G models. peak maximum. Medical Stock and Vibration Transient Response Per Mil-Std-810D, Method 514.3, Category 1, Procedure 1. <50 microseconds for 50% load change. Per Mil-Std-810D, Method 516.3, Procedure III. Short Circuit Protection Storage Automatic current limit/foldback. -40 to +85 C. Overvoltage Protection Built-in on all 5 V models, set at 6.2 V 0.4 V. Other models use optional overvoltage protection. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 116Commercial/Medical International + Linears Commercial Medical Voltage Current Case Model (Single) Model HA2-1.5-A+ 2AV 1B.5 HB2-3-A+ 2AV 3B HC2-6-A+ 2AV 6C HN2-9-A+ 2AV 9N HD2-12-A+ 2AV 1D2 HE2-18-A+* 2AV 1E8 ML5-OV-A 5AV 1L.0 HA5-1.5-OV-A+ 5AV 1B.5 HB5-3-OV-A+ MB5-3-OV-A 5AV 3B HC5-6-OV-A+ MC5-6-OV-A 5AV 6C HN5-9-OV-A+ 5AV 9N HD5-12-OV-A+ MD5-12-OV-A 5AV 1D2 HE5-18-OV-A+* 5AV 1E8 F5-25-OV-A+* 5AV 2F5 G5-35-OV-A+* 5AV 3G5 CP197-A+* 5AV 5G0 ML12-0.5-A 1A2 V 0L.5 HA15-0.9-A+ (12 V) 1A2 V 0B.9 HB12-1.7-A+ MB12-1.7-A 1A2 V 1B.7 HC12-3.4-A+ MC12-3.4-A 1A2 V 3C.4 HN12-5.1-A+ 1A2 V 5N.1 HD12-6.8-A+ MD12-6.8-A 1A2 V 6D.8 HE12-10-2-A+* 1A2 V 1E0.2 F15-15-A+* (12V) 1A2 V 1F6 ML15-0.4-A 1A5 V .L4 HA15-0.9-A+ 1A5 V 0B.9 HB15-1.5-A+ MB15-1.5-A 1A5 V 1B.5 HC15-3-A+ MC15-3-A 1A5 V 3C HN15-4.5-A+ 1A5 V 4N.5 HD15-6-A+ MD15-6-A 1A5 V 6D HE15-9-A+* 1A5 V 9E F15-15-A+* 1A5 V 1F5 ML24-0.28-A 2A4 V .L28 HA24-0.5-A+ 2A4 V 0B.5 HB24-1.2-A+ MB24-1.2-A 2A4 V 1B.2 HC24-2.4-A+ MC24-2.4-A 2A4 V 2C.4 HN24-3.6-A+ 2A4 V 3N.6 HD24-4.8-A+ MD-24-4.8-A 2A4 V 4D.8 HE24-7.2-A+* 2A4 V 7E.2 F24-12-A+* 2A4 V 1F2 HA24-0.5-A+ (28V) 2A8 V 0B.5 HB28-1-A+ MB28-1-A 2A8 V 1B HC28-2-A+ MC28-2-A 2A8 V 2C HN28-3-A+ 2A8 V 3N HD28-4-A+ MD28-4-A 2A8 V 4D HE28-6-A+* 2A8 V 6E F24-12-A+* (28V) 2A8 V 1F0 HB48-0.5-A+ 4A8 V 0B.5 HC48-1-A+ 4A8 V 1C HD48-3-A+** 4A8 V 3D HE48-4-A+* 4A8 V 4E F48-6-A+* 4A8 V 6F Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 117