Commercial/Medical D C P o w e r S u p p l i e s International + Linears International + Linears Summary: World-wide ac input ranges and safety standards Industry standard packages Commercial UL/CSA TUV/IEC approved models to UL/CSA 60950 EN/IEC60950-1 Burn-in with cycling 3-year warranty Capacitors have highest CV & ripple current ratings Medical Approved to UL2601-1/60601-1, IEC60601-1 and CSA601.1 Medical leakage 10 A MTBF 200,000+ hours per MIL-HDBK-217D (most units) All electrolytic caps rated at 105C Transformer insulation meets Class F (155C) Exceed FCC and CISPR22, Class B conducted emissions RoHS Compliant models available (G suffix) marked to LVD SPECIFICATIONS Remote Sensing Ac Input Provided on all models open sense lead protection built-in (except HA & HTAA 100, 120 and 240 Vac: +10%, -13% 215 Vac: +12%, -11% 47 to 63Hz. Toler- series). ance for 230 Vac operation is +15%, -10%. Derate output current 10% for 50 Stability Hz operation. 0.05% for 24 hours after warmup. Dc Output Temperature Rating See voltage rating chart. Adjustment range 5% minimum except HA series. 0 to 50C full rated, derated linearly to 40% at 70C. Line Regulation Temperature Coefficient 0.05% for a 10% change. 0.01%/C maximum. Load Regulation Efficiency 0.05% for a 50% load change. 5 V units: 45% 12 and 15 V units: 55% 20 and 24 V units: 60%. Output Ripple Logic Inhibit and Current-Share 3 mV +0.05% of output voltage, peak to peak maximum. All 3-terminal regu- F & G models. lator outputs: 3 mV +0.2% peak to peak maximum. Medical Stock and Vibration Transient Response Per Mil-Std-810D, Method 514.3, Category 1, Procedure 1. <50 microseconds for 50% load change. Per Mil-Std-810D, Method 516.3, Procedure III. Short Circuit Protection Storage Automatic current limit/foldback. -40 to +85 C. Overvoltage Protection Built-in on all 5 V models, set at 6.2 V 0.4 V. Other models use optional over- voltage protection. O All specifications are typical at nominal input, full load at 25 C unless otherwise statedCommercial Model (Single) Medical Model Voltage Current Case HB2-3-A+G 2 V 3 A B HC2-6-A+G 2 V 6 A C HE2-18-A+G 2 V 18 A E ML5-1-OV-A 5 V 1.0 A L HA5-1.5-OV-A+G 5 V 1.5 A B HB5-3-OV-A+G 5 V 3 A B HC5-6-OV-A+G 5 V 6 A C HN5-9-OV-A+G 5 V 9 A N HD5-12-OV-A+G 5 V 12 A D HE5-18-OV-A+G 5 V 18 A E F5-25-OV-A+*G 5 V 25 A F G5-35-OV-A+ * (1) 5 V 35 A G CP197-A+G 5 V 50 A G ML12-0.5-A 12 V 0.5 A L HA15-0.9-A+ (12 V)G 12 V 0.9 A B HB12-1-7-A+G MB12-1-7-A 12 V 1.7 A B HC12-3.4-A+G MC12-3.4-A 12 V 3.4 A C HN12-5.1-A+G 12 V 5.1 A N HD12-6.8-A+G MD12-6.8-A 12 V 6.8 A D HE12-10-2-A+G 12 V 10.2 A E ML15-0.4-A 15 V .4 A L HA15-0.9-A+G 15 V 0.9 A B HB15-1.5-A+G MB15-1.5-A 15 V 1.5 A B HC15-3-A+G MC15-3-A 15 V 3 A C HN15-4.5-A+G 15 V 4.5 A N HD15-6-A+G MD15-6-A 15 V 6 A D HE15-9-A+G * 15 V 9 A E F15-15-A+G * 15 V 15 A F HA24-0.5-A+G 24 V 0.5 A B HB24-1.2-A+G MB24-1.2-A 24 V 1.2 A B HC24-2.4-A+G MC24-2.4-A 24 V 2.4 A C HN24-3.6-A+G 24 V 3.6 A N HD24-4.8-A+G MD24-4.8-A 24 V 4.8 A D HE24-7.2-A+G * 24 V 7.2 A E F24-12-A+G * 24 V 12 A F HA24-0.5-A+ (28 V)G 28 V 0.5 A B HB28-1-A+G MB28-1-A 28 V 1 A B HC28-2-A+G MC28-2-A 28 V 2 A C HN28-3-A+G 28 V 3 A N HD28-4-A+G MD28-4-A 28 V 4 A D HE28-6-A+G * 28 V 6 A E F24-12-A+(28 V)G * 28 V 10 A F HB48-0.5-A+G 48 V 0.5 A B HC48-1-A+G 48 V 1 A C HD48-3-A+G ** 48 V 3 A D HE48-4-A+G 48 V 4 A E F48-6-A+G * 48 V 6 A F Notes: 1. All single output models have isolated outputs. 2. Model G5-50-OV-A+ not RoHS compliant