110W Single Output110W Single Output 110W Single Output110W Single Output TB110 FTB110 Familyamily TB110 FTB110 Familyamily Industrial GrIndustrial Gradeade Industrial GrIndustrial Gradeade FEATURES AND BENEFITS Compliant to High Levels of EMC Per Meets Class B Conducted EMI with 6db Margin Industrial EN61000-4 Class B Radiated EMI with 3db Margin 15kV ESD (Air), 8kV (Contact) Up to 110W Output Power 4kV Surge Universal Input 90-264VAC Input Range >10,00,000 Hrs. MTBF (50C) Up to 90% Efficiency >15 Years E-Cap Life 5V 1A Standby Output 3 Years Warranty Class I and II Input Models DC OK Signal, Inhibit, Power Good Signals 2 x 4 x 1.4 Package Approved to EN/CSA/IEC/UL62368-1 MODEL SELECTION 2 Model Output Output Current Ripple & Noise Total OVP 1 3 Efficiency MTBF 4 Number Voltage (Nom) (pk-pk) Regulation Threshold w/Air Convection TB110S12K 12V 8.7A 6.7A 89% 120mV 2% 15.0 2.0V 5,00,000 TB110S24K 24V 4.3A 3.3A 89% 240mV 2% 28.0 2.5V 5,00,000 TB110S48K 48V 2.1A 1.6A 89% 480mV 2% 55.0 4.0V 5,00,000 Notes : 1. Efficiency values listed are typical and are measured at 115Vac input, full load output current, at an ambient temperature of 25C. 2. Measured at 25C ambient with noise probe directly at end of 6 twisted pair terminated with 0.1F ceramic and 10F low ESR capacitors. Values will be higher at ambient temperatures below 0C. 3. MTBF values are in hours, per Telcordia SR-332, Issue 3, 25C, full rated load (w/airflow) at 110VAC input. 4. Change the K suffix to C for Input Class II (ungrounded) models. INPUT OUTPUT 85-264VAC, Single phase Main output: 20ms AC Input Hold-Up Time 5Vsb output: 100ms (Safety approved to 90-264VAC) From loss of AC input at 115 VAC, Full load 25C Input Current 1.8A max at 110VAC, 0.9A max at 240VAC Main output: <1second at 115VAC Turn On Time 40Arms max within 1/2 line cycle, Cold start at 5Vsb output: <250ms at 115VAC Inrush Current 25C. See application note 110W with 200LFM airflow 80W convection Input Fuses 3.15A, 250VAC, Line and neutral inputs Output Power cooled, -20C to 50C ambient. 85VAC to 264VAC See chart for de-rating above 50C Earth Leakage Current <500mA 264VAC, 60Hz input, NC 12V to 48V DC. Output Voltage Efficiency 88% - 90% typical at 115/230VAC, 25C See models chart for part numbering Main output: <70ms 500S typ response time for return to within Rise Time Transient Response 0.5% of final value for a 50% load change 5Vsb output: <70ms i/t<0.2A/s. Max voltage deviation is 3.5% Turn-On Input Voltage 70-85VAC, Full spec performance at 85VAC Voltage Adjustability +/- 10% Turn-Off Input Voltage <75VAC 8VAC Not required Minimum Load Total Regulation 2.0 % for all models TB110 Datasheet v1220 Copyright 2020 SL Power Electronics Corp. All rights reserved. Page 1 TB110 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved.110W Single Output110W Single Output 110W Single Output110W Single Output 110W Single Output110W Single Output TB110 FTB110 Familyamily TB110 FTB110 Familyamily TB110 FTB110 Familyamily Industrial GrIndustrial Gradeade Industrial GrIndustrial Gradeade Industrial GrIndustrial Gradeade PROTECTION SAFETY Over Temperature Power shuts down at temperature of TBD EN/CSA/IEC/UL62368-1 Protection (OTP) (typical) at full load. Auto-recovery Safety Standards Over Load 115% - 200% of rated output current value Protection (OCP) Hiccup mode, Auto-recovery Operating: Half-sine shock waveform. Impact Acceleration: 20g, Pulse duration: 11ms Short Circuit Short across the output terminals will not cause Shock Cycles: 3 times per axis in X,Y, Z direction Protection (SCP) damage to the unit. Hiccup mode, Auto-recovery (IEC 60068-2-27) Non-operating: Half-sine shock waveform Impact Acceleration: 50g, Pulse duration: 6ms Overvoltage Latches off when output voltage is with range as Cycles: 3 times per direction on 3 axes (X,Y. Z) Protection (OVP) shown in table. Requires AC power cycle to reset Outputs protected against momentary reverse Output Reverse current less than 20A peak for less than 10ms Voltage Protection with 0.5A average. Sustained reverse current at ISOLATION SPECIFICATIONS high levels may damage unit <2% overshoot at turn-on Input-Output: 3,000VAC Overshoot <1% overshoot at turn off, Under all conditions Input-Ground: 1,800VAC Isolation Output-Ground: 500VAC RELIABILITY AUXILIARY SIGNALS >1,000,000 hours 110/220VAC, 50C MTBF 5VDC 1A, +/-5% regulation over all changes in GB Telcordia SR-332 issue 3 5V Standby Output main output load current >15 years in use condition of 40C ambient, at Logic HIGH or open = ON E-Cap Life 12h/day, 261 days/year. Additional information Inhibit Logic LOW or short to ground = OFF on other use profiles available on request Signal is high after the main output is within regulation band upon AC turn on. Goes low with Power Good/Power Fail 4ms min. Before the main DC output drops STANDARDS below 90% of nominal value when AC turns off IPC 610 Class 2 ENVIRONMENT Operating Temperature -20C to +70C. Turn on -40C at >=120VAC Operating: Sinusoidal Frequency: 10-500Hz, Impact Acceleration: 1g, Sweep rate: 1 octave/min Vibration Cycles: 10 times per axis in X, Y, Z direction (IEC 60068-2-6) Random Vibration: (IEC 60068-2-64) 2 Operating: 0.003g /Hz, 1.224grms overall, 3 axes, 10 min per axis, 1-500Hz 2 Non-operating: 0.02g /Hz, 3.1grms overall, 3 axes, 1 hour per axis, 20-500 Hz Operating: -500m to 5,000m Altitude Non-operating: -500 to 40,000ft Relative Humidity 5% to 95%, Non-condensing Storage Temperature -40C to +85C Weight 180g, Typical Dimensions W: 2.0 x L: 4.0 x H: 1.4 TB110 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. TB110 Datasheet v1220 Copyright 20 20 SL Power Electronics Corp. All rights reserved. Page 2 TB110 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved.