65W Single Output TB65 Family Industrial Grade FEATURES AND BENEFITS Industrial 2.0 X 3.5 X 1.3 Package >10 Year E-Cap Life Up to 65W Convection Cooled Output Power Universal Input 90VAC264VAC Input Range Up to 90% Efficiency DC Ok Signal, PSU Temperature Signal Compliant To High Levels Of EMC Per EN61000-4 Class I and II Input Models 15kV ESD(Air), 8kV(Contact), 4kV Surge 3 Year Warranty Meets Class B Conducted EMI with 6db Margin, Class B Radiated EMI with 3db Margin Approved to EN/CSA/IEC/UL62368-1 MODEL SELECTION 2 Output Output Ripple & Noise Total OVP 4 1 3 Model Number Efficiency MTBF Voltage (Nom) Current (pk-pk) Regulation Threshold 14.0V 1.1V 5,00,000 TB65S12K 12V 5.4A 88% 120mV 3% 21.0V 2.0V 5,00,000 TB65S15K 15V 4.3A 88% 180mV 3% 28.0V 2.5V 5,00,000 TB65S24K 24V 2.7A 90% 240mV 3% 46.3V 3.0V 5,00,000 TB65S36K 36V 1.8A 88% 360mV 3% 55.0V 4.0V 5,00,000 TB65S48K 48V 1.35A 90% 480mV 3% Notes: 1. Efficiency values listed are typical and are measured at 115VAC input, full load output current, at an ambient temperature of 25C. 2. Measured at 25C ambient with noise probe directly at end of 6 twisted pair terminated with 0.1F ceramic and 10F low ESR capacitors. Values will be higher at ambient temperatures below 0C. 3. MTBF values are in hours, per Telcordia 332, Issue 6, 25C, full rated load (w/airflow) at 110VAC input. 4. Change the K suffix to C for Input Class II (ungrounded) models. TB65 Datasheet v1220 Copyright 20 20 SL Power Electronics Corp. All rights reserved. Page 165W Single Output TB65 Family Industrial Grade INPUT OUTPUT Input Voltage and 85VAC264VAC, single phase (Safety Approved to 12VDC to 48VDC. See models chart for part Output Voltage Frequency 90VAC264VAC) numbering Input Current 1.5A at 110VAC, 1A at 240VAC 65W continuous convection cooled, -20C to 50C Output Power ambient. 85VAC to 264VAC. See chart for derating 40Arms maximum within a half line cycle, cold Inrush Current above 50C start at 25C. See application note Turn On Time <2 seconds at 110VAC Input Fuses 3.15A, 250VAC, line and neutral inputs 20mS min. from loss of AC input at 110VAC, full Hold-up Time Earth Leakage Current <500A 264VAC, 60Hz input, NC load, 25C (Input to Earth) Output Voltage Patient Leakage 10% (5% for 48V model) Adjustment Current (Output to <4 mA 264VAC, 60Hz input 500S typ. response time for return to within Earth) Transient Response 0.5% of final value for a 50% load change, 88%90% typical at 115VAC/230VAC, 25C. Efficiency i/t<0.2A/s. Max. volt. deviation is 3.5% See chart for additional details Rise Time <30mS, 56V model: <35mS IT Characteristic See table below Total Load Regulation 1.0 % for all models Minimum Load Not required RELIABILITY High Frequency (100Khz20Mhz) - <50mA pk-pk, 6mA rms CM current. See Application Note 5,72,500 hours 110VAC/220VAC, 25C Bellcore Common Mode Noise MTBF Low Frequency (50Hz120Hz) - <50mA pk-pk, issue 6 6m Arms CM current. See Application Note >10 years in use condition of 40C ambient, at -20C to +70C. E-Cap Life 12 hours/day, 261 days/year. Additional information Turn-On & Turn on Temperature = -40C at 120VAC, allowing on other use profiles available on request Operating Temperature x seconds for stabilization. De-rated output power at 70C = 45.5W ISOLATION SAFETY Input-Output: 3000VAC Isolation Input-Ground: 1900VAC Output-Ground: 500VAC Safety Standards EN/CSA/IEC/UL62368-1 PROTECTION AUXILIARY SIGNALS Overtemperature Power shuts down at temperature of 70C (typical) Protection at full load. Hiccup Mode, Auto-recovery During normal operation, this signal is logic 115%200% of rated output current value. Hiccup HIGH. Signal will go LOW for output less than Overload Protection DC OK Mode, Auto-recovery 90% (typical) of nominal. Green LED will light on PCB top side during normal operation. Overvoltage Latches off when output voltage is with range as Protection shown in table. Requires AC Power cycle to reset Provides resistive value indicating internal PSU Temperature temperature of power supply. See Temperature Short Circuit Short across the output terminals will not cause Sensor Conversion Table below. Protection damage to the unit. Hiccup Mode, Auto-recovery Outputs protected against momentary reverse Output Reverse current less than 20A peak for less than 10mS with Voltage Protection 0.5A average. Sustained reverse current at high levels may damage unit. TB65 Datasheet v1220 Copyright 20 20 SL Power Electronics Corp. All rights reserved. Page 2