TE240 240W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 240W of AC-DC Power Universal Input 90-264Vac Input Range IP22 Rated Enclosure Meets Heavy Industrial Levels of EN61000 EMC Requirements Meets EN55011/CISPR11, FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin nd Approved to EN/IEC/UL60950-1, 2 Edition, Am. 2 E-cap life of >7 years 3 Year Warranty Optional AC Input On/Off Switch Description A high performance AC to DC external power supply family designed for test & measurement and industrial applications. Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial levels of various EN61000-4-x standards for EMC. The TE240 series models also meet Class B conducted and radiated EMI per FCC Part 15, EN55022, CISPR22. Designed to allow easy integration with test and measurement equipment and other industrial applications. Model Selection Model Output Output Ripple & Line Load Output Cable Input 4 Noise & Connector Configuration Number Volts Current Power Regulation Regulation TE240A1251F01 12.0V 16.6A 200W 120mV pk-pk 1% 5% 6 pin Molex Type, p/n 39- Class I Desktop, TE240A2451F01 24.0V 10.0A 240W 240mV pk-pk 1% 5% 01-2060 or equivalent. See IEC60320 C14 outline drawing for pinout TE240A2851F01 28.0V 8.60A 240W 280mV pk-pk 1% 5% Receptacle information. TE240A4851F01 48.0V 5.00A 240W 480mV pk-pk 1% 5% Notes: 1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1F ceramic and 47F low ESR capacitors. 2. The DC output is floating. For Input Class I models, AC GND is connected to output common (-), on models with the letter B inserted in the model number where the A is located: (TE240B1251F01). 3. All specifications are typical at nominal input, full load, at 25 C ambient unless noted. 4. Consult factory for availability of 28V output model. General Specifications AC Input 100-240Vac, 10%, 47-63Hz, 1 Turn On Time Less than 1 sec 115Vac, full load Input Current 115Vac: 2.4A, 230Vac: 1.2A Hold-up Time 20mS min., at full Load, 100Vac input Overtemperature Will shutdown upon an over-temperature 264Vac, cold start: will not exceed 60A Inrush Current condition, auto-recovery. Protection F1, F2: 3.15A, 250Vac fuses (line & neutral Input Fuses Overload Protection 115 to 160% of rating, Hiccup Mode lines) provided on all models Earth Leakage Input-GND: <500A 264Vac, 60Hz, NC Short Circuit Hiccup Mode, auto recovery. Output-GND: <4mA 264Vac, 60Hz, NC Current Protection Meets US DoE Efficiency Level VI average Overvoltage 110 to 130% of output voltage (max. 60V on Efficiency efficiency levels 48V model), hiccup mode Protection www.slpower.com TE240 Rev 2.1 15-AUG-16 1TE240 240W Single Output External Power Test & Measurement/Industrial Series General Specifications (continued) Input-Output: 4000Vac 240W continuous See models chart for Input-Ground: 1500Vac Output Power Isolation specific voltage model ratings. Output-Ground: 500Vac No Load Input <0.210W per DoE Efficiency Level VI EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2 Safety Standards Requirements Power -20C to +70C. Derate above 40C. Operating Ripple and Noise See models chart on pg 1. Start Up at -30C, full load, (warmup period before Temperature all parameters are within published specifications). Case Temperatures are within regulatory guidelines. Care should be taken to avoid Output Voltage See models chart on pg 1. Case Temperature prolonged contact with skin or other heat sensitive surfaces. 500 s response time for return to within 0.5% Transient of final value for any 50% load step over the Temperature See Derating Curves range of 5% to 100% of rated load, i/ t< Response Derating 0.2A/ s. Max. voltage deviation is +/-3.5%. >7 year life based on calculations at >250,000 hours, full load, 110 & 220Vac 115Vac/60Hz & 230Vac/50Hz, ambient 25C E-Cap Life MTBF at 24 hrs per day, 365 days/year, 6 power up input, 25C amb., per Telcordia 332 Issue 6. cycles per day. (80% load on 12V model at 115Vac) Weight 700g Storage Temperature -40C to +85C Operating: to 5000m (derate to TBD temp. 1.4m from table top to wooden platform, 6 Safety Drop Test Altitude above 3000m). faces. Non-operating: -500 to 40,000 ft. W: 2.65 x L: 8.3 x H: 1.7 Dimensions Relative Humidity 5% to 95%, non-condensing W: 67.4mm x L: 212.4mm x H: 45mm Operating: 0.003g/Hz, 1.5grms overall, 3 Operating: Half-sine, 20gpk, 10mS, 3 axes, axes, 10 min/axis, 1-500Hz. 6 shocks total Non-Oper.: random waveform, 3 minutes per Non-Operating: Half-sine waveform, impact Vibration axis, 3 axes and Sine waveform, Vib. Shock acceleration of 50G, Pulse duration of 6 mS, frequency/acceleration: 10-500Hz/1g, sweep Number of shocks: 3 for each of the three rate of 1 octave / minutes, Vibration time of 10 axis sweeps / axes, 3 axes All specifications are typical at nominal input, full load, at 25 C ambient unless noted. EMI/EMC Compliance Conducted Emissions: EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac Radiated Emissions: EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac High Frequency (100kHz-20MHz): <20mA pk-pk Common Mode Noise: Low Frequency (50-120Hz): <5Vrms Electro-Static Discharge (ESD) EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A Immunity on Power ports: Radiated RF EM Fields Susceptibility EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz Electrical Fast Transients (EFT) /Bursts: EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A Surges, Line to Line (Diff Mode) and Line EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A to GND (CMN Mode) Conducted Disturbances induced by RF EN55022/IEC61000-4-6, 10Vrms Level 3, in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz Fields Rated Power frequency magnetic fields EN55024/IEC1000-4-8, Level 4: 30A/m, 50/60 Hz EN55024/IEC61000-4-11: --100% dip for 20mS, Criteria A Voltage Interruptions, Dips, Sags & --100% dip for 5000mS (250/300 cycles), Criteria B Surges --60% dip for 100mS, Criteria B --30% dip for 500mS, Criteria A www.slpower.com TE240 Rev 2.1 15-AUG-16 2