240W Single Output External P240W Single Output External Powerower 240W Single Output External P240W Single Output External Powerower
TE240 FTE240 Familyamily TE240 FTE240 Familyamily
Industrial GrIndustrial Gradeade Industrial GrIndustrial Gradeade
FEATURES AND BENEFITS
Meets DoE efficiency level VI requirements Meets EN55011/CISPR11, FCC Part 15.109
Industrial
No load input power Class B conducted & radiated emissions, with
Average efficiency 6db margin
Up to 240W of AC-DC power
Approved to EN/IEC/UL60950-1, 2nd edition,
Am. 2
Universal input 90-264VAC input range
E-cap life of >7 years
IP22 rated enclosure
3 years warranty
Meets Heavy Industrial levels of EN61000
EMC requirements
Optional AC input on/off switch
MODEL SELECTION
Output Output Ripple & Line Load Output Cable Input
4
Volts
Model Number
1
Current Power Noise Regulation Regulation & Connector Configuration
120mV pk-pk
TE240A1251F01 12.0V 16.6A 200W 1% 5%
6 pin Molex type,
TE240A1551F01 15.0V 13.3A 200W 150mV pk-pk 1% 5%
p/n 39-01-2060 or Class I Desktop,
240mV pk-pk
TE240A2451F01 24.0V 10.0A 240W 1% 5% equivalent IEC60320 C14
See outline drawing for receptacle
280mV pk-pk
TE240A2851F01 28.0V 8.60A 240W 1% 5%
pinout information
TE240A4851F01 48.0V 5.00A 240W 480mV pk-pk 1% 5%
Notes : 1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1F ceramic and 47F low ESR capacitors.
2. The DC output is floating. For Input Class I models, AC GND is connected to output common (-), on models with the letter B inserted in the model number where the A is located:(TE240B1251F01).
3. All specifications are typical at nominal input, full load, at 25C ambient unless noted.
4. Consult factory for availability of 28V output model.
INPUT OUTPUT
AC Input 100-240VAC, 10%, 47-63Hz, 1 Hold-Up Time 20ms at full load, 100VAC input
Input Current Less than 1 sec @115VAC, Full load
115VAC: 2.4A, 230VAC: 1.2A Turn On Time
240W continuous See models chart for
Inrush Current 264VAC, Cold start: will not exceed 60A
Output Power
specific voltage model ratings
F1, F2: 3.15A, 250VAC fuses (line & neutral lines)
Input Fuses
Output Voltage See models chart on pg 1
provided on all models
Input-GND: <500A @ 264VAC, 60Hz, NC
Ripple and Noise See models chart on pg 1
Earth Leakage Current
Output-GND: <4mA @ 264VAC, 60Hz, NC
500s response time for return to within 0.5% of
Meets US DoE efficiency level VI average
Efficiency
final value for any 50% load step over the range
Transient Response
efficiency levels
of 5% to 100% of rated load, i/t< 0.2A/s
Max voltage deviation is +/-3.5%
No Load Input Power <0.210W per DoE efficiency level VI requirements
Notes : All specifications are typical at nominal input, full load, at 25C ambient unless noted. Notes : All specifications are typical at nominal input, full load, at 25C ambient unless noted.
TE240 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. Page 1 TE240 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved.240W Single Output External P240W Single Output External Powerower 240W Single Output External P240W Single Output External Powerower 240W Single Output External P240W Single Output External Powerower
TE240 FTE240 Familyamily TE240 FTE240 Familyamily TE240 FTE240 Familyamily
Industrial GrIndustrial Gradeade Industrial GrIndustrial Gradeade Industrial GrIndustrial Gradeade
PROTECTION
SAFETY
Overtemperature Will shutdown upon an over-temperature Safety Standards EN/CSA/UL/IEC 60950-1, 2nd edition, Am 2
condition, Auto-recovery
Protection
Operating: Half-sine, 20gpk, 10ms, 3 axes,
115 to 160% of rating, Hiccup mode
Overload Protection 6 shocks total
Shock Non-operating: Half-sine waveform, impact
Short Circuit Protection Hiccup mode, Auto recovery
acceleration of 50G, Pulse duration of 6 ms,
Number of shocks: 3 for each of the three axis
110 to 130% of output voltage
Overvoltage Protection
Notes : All specifications are typical at nominal input, full load, at 25C ambient unless noted.
(max 60V on 48V model), Hiccup mode
Safety Drop Test 1.4m from table top to wooden platform, 6 faces
Notes : All specifications are typical at nominal input, full load, at 25C ambient unless noted.
RELIABILITY
>250,000 hours, Full load, 110 & 220VAC input,
MTBF
25C amb, per Telcordia 332 Issue 6
ISOLATION SPECIFICATIONS
>7 years life based on calculations at
115VAC/60Hz & 230VAC/50Hz, ambient 25C at
Input-Output: 4,000VAC
E-Cap Life
24 hrs per day, 365 days/year, 6 power up cycles
Input-Ground: 1,500VAC
Isolation
per day. (80% load on 12V model at 115VAC)
Output-Ground: 500VAC
Notes : All specifications are typical at nominal input, full load, at 25C ambient unless noted. Notes : All specifications are typical at nominal input, full load, at 25C ambient unless noted.
ENVIRONMENT
-20C to +70C. Derate above 40C. Start Up at -30C, Full load, (warmup period before all parameters are within published
Operating Temperature
specifications)
Temperature Derating See derating curves
Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500Hz.
Vibration Non-operating: Random waveform, 3 minutes per axis, 3 axes and Sine waveform, Vib
Frequency/Acceleration: 10-500Hz/1g, sweep rate of 1 octave/minutes, Vibration time of 10 sweeps/axes, 3 axes
Case temperatures are within regulatory guidelines. Care should be taken to avoid prolonged contact with skin or other
Case Temperature
heat sensitive surfaces
Operating: to 5,000m (derate to TBD temp. above 3,000m)
Altitude
Non-operating: -500 to 40,000 ft
Relative Humidity 5% to 95%, Non-condensing
Storage Temperature
-40C to +85C
Weight 700g
Dimensions W: 2.65 x L: 8.3 x H: 1.7 W: 67.4mm x L: 212.4mm x H: 45mm
Notes : All specifications are typical at nominal input, full load, at 25C ambient unless noted.
TE240 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. TE240 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. Page 2 TE240 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved.