Power Protection and Conditioning 1 MCR Hardwired Series Power Line Conditioning with Voltage Regulation The MCR Hardwired Series provides excellent noise Features ltering and surge suppression to protect con nect ed 3% output voltage regulation equip ment from damage, deg ra da tion or misoperation. Noise attenuation Combined with the ex cel lent voltage regulation inherent to - 120 dB common mode Sola/Hevi-Dutys patented ferroresonant design, the MCR - 60 dB transverse mode can in crease the actual Mean Time Before Failure (MTBF) of pro tect ed equipment. The MCR is a perfect choice where Surge suppression tested to ANSI/IEEE dirty power, caused by impulses, swell, sags, brownouts and C62.41 Class A & B Waveform: waveform distortion can lead to costly downtime because of - <10 V let through typical damaged equip ment. Acts as a step-up or step-down transformer Harmonic ltering Hardwired Galvanic isolation provides exceptional circuit pro tec tion. 25 year typical MTBF No maintenance required Applications In dus tri al automation and control equip ment PLCs Machine tools Computer loads and electronic equipment Robotics Related Products Semiconductor fabrication equipment On-line UPS (S4K Industrial) Surge Suppression Three Phase Power Conditioners Selection Tables: Single Phase Group 2 MCR Series, 60 Hz Only Height Width Depth Ship Weight Design Elec VA Catalog Number Voltage Input Voltage Output (inch) (inch) (inch) (lbs) Style Conn 120 120, 208, 240, 480 120 9 4 5 15 1 D 63-23-112-4 250 120, 208, 240, 480 120 10 6 8 27 1 D 63-23-125-4 500 120, 208, 240, 480 120, 208, 240 13 9 7 37 1 E 63-23-150-8 750 120, 208, 240, 480 120, 208, 240 14 9 7 52 1 E 63-23-175-8 1000* 120, 208, 240, 480 120, 208, 240 17 9 7 62 1 E 63-23-210-8 1500* 120, 208, 240, 480 120, 208, 240 17 13 9 95 1 E 63-23-215-8 2000* 120, 208, 240, 480 120, 208, 240 18 13 9 109 1 E 63-23-220-8 3000* 120, 208, 240, 480 120, 208, 240 19 13 9 142 1 E 63-23-230-8 5000* 120, 208, 240, 480 120, 208, 240 28 13 9 222 1 E 63-23-250-8 7500** 208, 240, 480 120, 208, 240 27 26 9 362 2 F 63-28-275-8 10000** 208, 240, 480 120, 208, 240 28 26 9 446 2 F 63-28-310-8 15000** 63-28-315-8 208, 240, 480 120, 208, 240 28 38 10 710 3 F * Canadian option: cULus certied units must be ordered by changing -8 (UL only) to -C8. ** UL Listed Only. Use Group 3 for cULus. Gross Automation (877) 268-3700 www.solahevidutysales.com sales grossautomation.com 28 Gross Automation (877) 268-3700 www.solahevidutysales.com sales grossautomation.comPower Protection and Conditioning 1 Selection Tables: Single Phase Group 3 MCR Series, 60 Hz Only Height Width Depth Ship weight Design Elec VA Catalog Number Voltage Input Voltage Output (inch) (inch) (inch) (lbs) Style Conn 500 600 120, 208, 240 13 9 7 38 1 B 63-31-150-8 1000 600 120, 208, 240 17 9 7 62 1 B 63-32-210-8 2000 600 120, 208, 240 18 13 10 109 1 B 63-32-220-8 3000 600 120, 208, 240 19 13 10 142 1 B 63-32-230-8 5000 208, 240, 480, 600 120, 208, 240 28 13 10 221 1 A 63-29-250-8 7500 208, 240, 480, 600 120, 208, 240 27 25 10 360 2 A 63-29-275-8 10000 208, 240, 480, 600 120, 208, 240 28 25 10 441 2 A 63-29-310-8 15000 208, 240, 480, 600 120, 208, 240 28 38 10 706 3 A 63-29-315-8 Group 4 MCR Series, 50 Hz Only (5% output voltage regulation) Height Width Depth Ship weight Design Elec VA Catalog Number Voltage Input Voltage Output (inch) (inch) (inch) (lbs) Style Conn 120 110, 120, 220, 240, 380, 415 110, 120, 220, 240 9 6 8 24 1 C 63-23-612-8 250 110, 120, 220, 240, 380, 415 110, 120, 220, 240 11 6 8 27 1 C 63-23-625-8 500 110, 120, 220, 240, 380, 415 110, 120, 220, 240 13 9 7 40 1 C 63-23-650-8 1000 110, 120, 220, 240, 380, 415 110, 120, 220, 240 18 9 7 64 1 C 63-23-710-8 2000 110, 120, 220, 240, 380, 415 110, 120, 220, 240 18 13 10 113 1 C 63-23-720-8 3000 110, 120, 220, 240, 380, 415 110, 120, 220, 240 27 13 10 162 1 C 63-23-730-8 5000 110, 120, 220, 240, 380, 415 110, 120, 220, 240 30 13 10 266 1 C 63-23-750-8 7500 220, 240, 380, 415 110, 120, 220, 240 28 26 10 393 2 C1 63-28-775-8 10000 220, 240, 380, 415 110, 120, 220, 240 30 26 10 490 2 C2 63-28-810-8 15000 220, 240, 380, 415 110, 120, 220, 240 30 38 10 776 3 C2 63-28-815-8 Specifications Parameter Condition Value Input Continuous at full load (lower input voltage possible at lighter load) +10% to -20% of nominal Voltage For temporary surge or sags +20% to -35% of nominal 1 at Full Load & 80% of nominal input voltage I (VA/.89)/(V x 80%) Current in in See Operating Characteristics section for details. 50 Hz or 60 Hz depending on model Frequency Output V >80% and <110% of nominal 5% for 50 Hz units, 3% for 60 Hz units Line Regulation in At Nominal Input Voltage Current limited at 1.65 times rated current Overload Protection At full load within input range 3% total RMS content Output Harmonic Distortion -Common Mode 120 dB Noise Attenuation -Transverse Mode 60 dB General At Full Load Up to 92% Efficiency Storage Temperature Humidity <95% non-condensing -20 to +85C Humidity <95% non-condensing -20 to 50C Operating Temperature Full Resistive Noise 35 dBA to 65 dBA Audible Noise 60 Hz Models UL1012, CSA evaluated by UL Approvals 50 Hz Models CE (EMC & LVD) See General Information section for details 10 + 2 Years Warranty Notes: 1 - Consult user manual for fuse sizing. Gross Automation (877) 268-3700 www.solahevidutysales.com sales grossautomation.com 29 Gross Automation (877) 268-3700 www.solahevidutysales.com sales grossautomation.com