Power Supplies
GL Series: Single & Multi Output Switchers
The new GL series provides a broad range of AC/DC power
supply solutions that covers power ratings from 25 watts to
250 watts for use in various industrial applications requiring
standard footprint size and very high reliability.
These low-profile AC/DC switchers offer universal input
voltage with no switches or jumpers, ideal for higher volume E137632
worldwide applications.
Cover and Bracket Options
Catalog Number Description
All models feature:
Enclosure kit for the GL20 and GL40
GLX40
Industry standard footprints
Cover end fan kit for the GL250
GLX250-CEF
Universal input
Cover with top fan kit for the GL250/350
GLX250-CF
Full power to 50C
High demonstrated MTBF
Automatic overvoltage protection
Overload protection
Built-in EMI Filtering
Extensive safety approvals
Derated operation to 70C
2% regulation on main output
250 VA size enclosed
Two year limited warranty
Many models feature:
EN61000-3-2 Compliance
Supervisory outputs (5 V/12 V)
th
Wide-adjustable floating 4 output
Single wire current share
Remote Sense
Adjustable main output
Power Fail and DC Good signals
Wide-adjustable on single output models
Certifications and Compliances
Recognized Component, ITE
UL 60950
E137632
-CUL/CSA-C22.2 UL 60950-1
No. 234-M90
Certified, ITE
- CSA C22.2 CSA 60950-1
- IEC60950-1
Cover Options
Cover options can be ordered separately. They are
designed to simplify mechanical integration of the
power supplies into systems and add an extra measure
of electrical safety for service personnel.
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
163
January 2017Power Supplies
Specifications
GL20, GL40 GL50 GL60 GL250
Input
Input 85 - 264 Vac; 90 - 264 Vac 85 - 264 Vac
85 - 264 Vac; 120 - 300 Vdc
1
120 - 300 Vdc 127 - 300 Vdc 120 - 300 Vdc
Voltage
47-63 Hz , 400 40 Hz 47-63 Hz
Frequency
GL20: <15A peak
<18A peak
@ 115 Vac; <30A peak @ 230 Vac, cold GL250:
<60A peak @ 115 Vac,
start @ 25C. 20 A max.,
Inrush
@ 230 Vac, <36 A peak
cold start @ 25C.
Current GL40: <18A peak
cold start @ 25C @ 230 Vac,
@ 115 Vac; <36A peak @ 230 Vac, cold
cold start @ 25C
start @ 25C
80% - 85%
70% typical 70% typical
typical 75% typical at full load
Efficiency
at full load at full load
at full load
FCC Class B ; CISPR 22 Class B ;
EMI/RFI
EN55022 Class B
Output
Refer to the selection table
Power
Adjustment
-5, +10% 20% minimum for single output only
-5, +10% minimum 2:1 wide ratio
Range on
minimum models
Main Output
Hold-up
20 ms @ full load, 115 Vac nominal line 10/20 ms 115/230 Vac Input line 20 ms @ full load, 115 Vac nominal line 20 ms @ full load, 115 Vac nominal line
Time
Short circuit protection on all outputs.
Overload
Primary overload protection
5 V output; 5.7 to
5 V output: 5.7
6.7 Vdc. Other
5 V output; 5.7 - 6.7 Vdc. Other outputs to 6.7 Vdc.
Overvoltage
outputs 10% to 30-50% above nominal output
10% to 25% above nominal output Other outputs 10% to 25% above
Protection
25% above
nominal output
nominal output
Compensates for 0.5 V lead drop
minimum; Will operate without remote
Remote Sense
sense connected, Reverse connection
protected
General
2
Storage: -40C to +85C; Operating: 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C, -20C start up.
Temperature
Electro-
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 or EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
magnetic
Susceptibility
Operating; non-condensing up to 95% RH
Humidity
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500 Hz
Vibration
(2 G peak 8 Hz to 500 Hz for GL500)
>550,000 hours demonstrated at full load and 25C ambient conditions
MTBF
EN60950, cRUus: UL/CSA 60950 E132002, CE Mark (LVD)
Safety
Notes:
1. Proper circuit protection required when operating with a DC input voltage. 2. Regulation and ripple may deviate from the spec at -20C start up.
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
164