GLQ110 Series Installation & Operating Instructions
Installation & Safety Output Ratings
To comply with the published safety standards, the following must be observed when Convection Cooling 30 CFM Forced Air Cooling
Output Voltage
using this power supply: Model
Max. Output Max. Output Max. Output Max. Output
(V)
Current (A) Power (W) Current (A) Power (W)
1. Maximum ambient temperature for the power supply must not exceed 50C.
+5 9.0 11.0
+12 4.5 5
2. When installing the power supply in the end-use equipment, special attention GLQ112
-12 0.7 1.0
is required to ensure safety compliance with the following safety standards:
5 to 25 2.5 3.0
UL60950, EN60950-1, IEC60950-1, and CSA22.2 No. 234-M90; including the
+5 9.0 11.0
requirements for creepage distances, clearances, and distance through insulation
+15 4.5 5.0
between primary wiring and earth or secondary (SELV) wiring. GLQ113 80 110
-15 0.7 1.0
5 to 25 2.5 3.0
3. The power supplys rated input voltage is automatically selected. Please refer to
+5 9.0 11.0
the specification sheet for the input voltage range.
+12 4.5 5.0
GLQ114
4. The maximum output power of the supply must not exceed the rating indicated in -12 0.7 1.0
the specification sheet. +24 3.5 4.5
5. The earth ground wire must be connected only to the point marked with the earth
ground symbol (on the unit).
Connector PIN Designation
6. Hazardous voltages exist in the primary circuits. Disconnect the power supply
Input Connector PIN GLQ112 GLQ113 GLQ114
before servicing.
1 GND
SK1 3 Neutral
7. When operating with a dc input voltage range, the unit input must be protected by
5 Line
a dc rated fuse in the end-use installation system.
Output Connector PIN GLQ112 GLQ113 GLQ114
8. The internal fuse should only be replaced with a 4 A, 250 V ac, Type SP0001.1010
1
manufactured by Schurter AG, Type 216004 manufactured by Littelfuse or Type
2 +5 V
S501 manufactured by Cooper.
3
4
9. This power supply is marked following the provisions of the Low Voltage
5
Common
Directive, 2006/95/EC.
6
SK2
7
For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or
8 +12 V +15 V +12 V
send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for
9 +12 V +15 V +12 V
additional product information and specification sheets.
10 -12 V -15 V -12 V
11 +5 V to +25 V +5 V to +25 V +24 V
12 -5 V to -25 V -5 V to -25 V Common
1 +Sense
SK201
2 -Sense
1 P OK
SK202
2 GND
P/N: A272-168 Rev 2 12/29/09 Ref: 033610016025 V O/P ADJ
GLQ110 Series Installation & Operating Instructions
Mechanical Outline Mechanical Dimensions
.25 [6.35]
SK201
SK202
1
4.28
4.00
SK2 [108.6]
[101.6]
2.50
5 ~ 25 V
3.50
O/P ADJ
[63.5]
[88.9]
12
1
3
SK1
5
6.40 [162.6]
6.50 [165.1]
.25 [6.35]
7.30 [185.5]
7.00 [177.8]
Bottom View with Optional L-Bracket
Top View
2.20
[56.0]
.86
[21.8]
5.90 [150.0]
Side View with Optional L-Bracket
All dimensions are in inches [mm]
Screw size: #6-32
GLQ112, GLQ113, and GLQ114 are commercial designations of model numbers LPQ112, LPQ113, and LPQ114 respectively.
While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. 2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice.