Uninterruptible Power Supplies S3K Mini-Tower Line-Interactive UPS The S3K is an economical choice for those applications requiring the performance of a sinewave output, line interactive UPS with the mini-tower shape for cabinet installations. The S3K Series protects against most severe power disturbances through state-of-the-art, line-interactive technology. Most power disturbance corrections are accomplished without transferring to the internal battery. Utility power is continually protected by the S3K Series UPS and internal battery life is optimized. The UPS has built in protection for under and over voltage E179213 conditions including low-energy lightning surges introduced on the input power source. All S3K Series UPS are provided with an input circuit protector and surge protected data line connectors. The S3K Series UPS is provided with a battery Certifications and Compliances test function. Should the battery fail this test, the UPS will Listed, UPS Equipment display a warning to indicate that the battery needs to be - UL 1778, CSA C22.2 No. 107.3 replaced. IEC 60801-2, Level 4 / IEC 60801-4, Level 4 / ANSI Applications C62.41 Category A & B Workstations RoHS Compliant PLCs Robotics and Process Control Related Products Industrial Automation Systems Portable MCR Power Conditioners Automatic Service & Dispensing Equipment Surge Protective Devices Active Tracking Filters Features Mini-Tower design for control cabinet installation. Battery Back-up Times Chart Automatic voltage regulation (AVR) topology saves Load % Watts S3K700 S3K1000 S3K1600 battery power for deep voltage sag situations. 20 45 37 27 Sine wave output 40 21 18 12 User replaceable,hot swappabl batteries 50 14 13 10 (Downtime for battery replacement not required). 70 9 8 6 RS-232 communications port 100 5 4 3 Built-in surge protection Note: Back-up times are at 25C with 100% capacity batteries and resistive Cold start capability (DC power on) loads. Telephone/modem spike protection Power management software is included (UPSMON). 50/60 Hz auto sensing Fully digitized, microprocessor controlled Protects against most adverse power conditions including: - Frequency variations - Surge - Sags - Spike - Blackouts - Over and under voltages Two year limited warranty Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 73 January 2017Uninterruptible Power Supplies Selection Table Capacity Catalog Volts, Frequency Typical Back-up Approx. Ship Weight Input Plug/Output Receptacle (VA/W) Number (In/Out) Time (minutes)* lbs (kg) 700/480 120/120, 50/60 Hz 5/14 (Detached) 5-15P / (4)5-15R 34.1 (15.50) S3K700 1000/750 120/120, 50/60 Hz 4/13 (Detached) 5-15P / (4)5-15R 37.0 (16.80) S3K1000 1440/1200 120/120, 50/60 Hz 3/10 (Attached) 5-15P / (6)5-15R 70.4 (32.00) S3K1600 * Full/Half Load (in minutes). Specifications Catalog Number S3K700 S3K1000 S3K1600 700/480 1000/750 1440 */1200 Power Rating (VA/Watts) Dimensions inches (mm) 8.30 x 5.50 x 17.20 8.90 x 6.70 x 17.70 Unit (H x W x D) (210.0 x 140.0 x 436.0) (226.0 x 170.0 x 450.0) 11.75 x 10.50 x 19.20 14.00 x 12.00 x 22.25 Shipping (H x W x D) (300.0 x 265.0 x 492.0) (358.0 x 307.0 x 581.0) 34.1 (15.50) 37.0 (16.80) 70.4 (32.00) Approx. Shipping Weight - lbs (kg) Input AC Parameters 103-132 Vac Voltage Range 6 ft. detachable with NEMA 5-15P Attached 5-15P Plug Maintains output to 120 Vac -14%, when input is 120 Vac, -25% Line to Boost Transfer Maintains output to 120 Vac +10%, when input is 120 Vac, +23% Line to Buck Transfer 45-55 Hz or 55-65 Hz auto sensing Frequency Output AC Parameters 103 Vac to 132 Vac Voltage (4) NEMA 5-15R (6) NEMA 5-15R Receptacles 50 Hz or 60 Hz 0.5% Frequency Sine wave Waveform 100-110% Nominal Overload Warning 200% Nominal Overload Shutdown Battery Parameters Valve-regulated, non-spillable, lead acid Type 5/14 4/13 3/10 Battery Time (mins) (FL/HL) 4 x 12 V x 7 AH 6 x 12 V x 7 AH Qty. x Voltage x Rating 2-4 ms typical Transfer Time See Battery Back-up Times Charts Back-up Time 4 Hours Recharge Time to 90% rated capacity, after full discharge into resistive load Environmental 0C to +40C Operating Temperature -15C to +50C Storage Temperature 0% to 95%, non-condensing Relative Humidity Up to 10,000 ft. (3000 m) at 35C without derating Operating Elevation <40 dBA, (beyond 1 m) <45 dBA, (beyond 1 m) Audible Noise Standards FCC Part 15, Subpart B, Class A EMC * Note: 1200W at 0.75 power factor equals 1600VA. Line cord limits total load to 1440 VA (max). Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 74 January 2017