Power Supplies
Silver Line Series Single & Multi-Output Linears
The Silver Line series follows the industry accepted
footprint for open frame, linear power supplies. Standard
screw terminal connections and optional covers are offered
for safety considerations.
Applications
Industrial Control Circuits and Components
Instrumentation
E137632
Drives
Specifications
CNC Machinery
Parameter Condition Limit
Equipment for food industry
Input
Microprocessor Circuits
100/120/220/230/240
Input Voltage
Vac Selectable
Analog Circuits
47-63 Hz
Input Frequency
Noise sensitive Circuitry and Sensors
Output
for 10% change 0.05%
Line Regulation
Features
for 50% change 0.05%
Load Regulation
3.0 mV maximum
Easy-to-install screw terminal connections
Ripple
Peak-to-Peak
Cover options
DC Output
5% Minimum
Adjustment Range
Industry standard footprint
All 5-Volt outputs include
Universal input and approvals (115/230 Vac)
build-in OVP as standard
Overvoltage
(setting is 6.2 V 0.4 V)
Low noise, extremely quiet DC output. For noise
Protection
OVP is optionally
sensitive or analog circuitry.
available on other types
Transient
Fast transient response. Ideal for test applications.
at 50% Load Changes 50 msec.
Response Time
Built-in OVP on 5 V models and optional on
Overload Automatic current
12, 15 and 24 V models
limit foldback
Protection
Available to compensate
Automatic resetting overload protection
for output voltage drop 0.5 Vdc
Remote Sensing
Short circuit protected
on selected models.
General
Two year limited warranty
Operating
Derate to 40% at +70C 0 to +50C
Temperature Range
Certifications and Compliances
Storage
-25C to +85C
Temperature Range
Recognized Component, ITE
UL 60950
E137632
Temperature
- UL 60950-1
CUL/CSA-C22.2 0.01% 0C
No. 234-M90 Coefficient (Typical)
Certified, ITE
After warm-up .5%
Stability
- CSA C22.2 CSA 60950-1
For most system
Linear power supplies
applications they will
have inherently low
meet requirements of
EMI/RFI
conducted and radiate
FCC Class B and VDE
noise levels
- IEC60950-1
0871 for Class B
Derate power by an additional 15%
RoHS Compliant Cover Option
Forced air. 20 CFM required for full rating
Cooling
Derate 30% without cooling
Specifications are typical. Load Regulation on outputs without Remote Sense, .1% typical.
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
156
January 2017Power Supplies
SL Series Selection Table Dimensions - inches (mm)
Catalog Number Output 1 Output 2 Output 3 Case
2
5 V @ 3 A * A
SLS-05-030-1T
2
B1
SLS-05-060-1T 5 V @ 6 A *
2
C
SLS-05-090-1T 5 V @ 9 A *
2
I2
SLS-05-120-1T 5 V @ 12 A *
2
12 V @ 1.7 A or
A
SLS-12-017T1
15 V @ 1.5 A
2
12 V @ 3.4 A B1
SLS-12-034T
2
SLS-12-051T 12 V @ 5.1 A C
2
12 V @ 6.8 A I2
SLS-12-068T
2
SLS-15-045T 15 V @ 4.5 A C
2
15 V @ 6 A I2
SLS-15-060T
SLS-24-012T 24 V @ 1.2 A v A
2
24 V @ 2.4 A B2
SLS-24-024T
Case A
2
24 V @ 3.6 A C
SLS-24-036T
2
24 V @ 4.8 A I2
SLS-24-048T
2
24 V @ 7.2 A K
SLS-24-072T
2
24 V @ 12.0 A L
SLS-24-120T
12 V @ 1 A or -12 V @ 1 A or
1
H1
SLD-12-1010-12T
15 V @ .8 A -15 V @ .8
12 V @ 1.8 A or -12 V @ 1.8 A or
1
D
SLD-12-1818-12T
15 V @ 1.5 A -15 V @ 1.5 A
2 2
12 V @ 3.4 A -12 V @ 3.4 A I3
SLD-12-3434-12T
2 2
15 V @ 3 A -15 V @ 3 A I3
SLD-15-3030-15T
2
2
12 V @ 3.4 A I1
SLD-12-6034-05T 5 V @ 6 A *
2
12 V@ 1.5 A C1
SLD-12-3015-05T 5 V @ 3 A *
12 V @ .4 A or -12 V @ .4 A or
1 2
H2
SLT 12-20404-12T 5 V @ 2 A *
15 V @ .4 A -15 V @ .4 A
2 2
12 V @ 1 A or -12 V @ 1 A
2
F
SLT 12-31010-12T1 5 V @ 3 A *
15 V @ .8 A or -15 V @ .8 A
-12 V @ 1.8
12 V @1.8 A or
2
SLT 12-61818-12T1 5V @ 6A * A or -15 V @ G2
15 V @1.5 A
1.5 A
Over Voltage Protector (OVP) Case B
6.2 V to 34 V
For Cases B through K J1
SLO-12-000-1
Adjustable @ 8 A
6.2 V to 34 V For Case A or Cases B through K
Cover Options
SLO-12-000-TB J2
Adjustable @ 8 A (when used with a cover)
Catalog Catalog
Notes:
Description Description
Number Number
* With Built-In OVP
Cover for Cases
Cover for Case A
SLCASA-CVR SLCASI-CVR
1. 12/15 Volt models are factory set for 12 Volt operation. 15 Volt operation
I1, I2, & I3
is field adjustable.
Cover for Case B Cover for Case K
SLCASB-CVR SLCASK-CVR
2. With Remote Sense (R.S.)
Cover for Case C Cover for Case L
SLCASC-CVR SLCASL-CVR
Note:
Covers are sold separately. When used, derate the power supply by 15%
of its rated value.
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
157
January 2017