IP67 SCP-X EXTREME ENVIRONMENT SERIES The IP67 SCP-X power supplies provide the versatility and cost-efficiency RECOMMENDED ELECTRICAL CONNECTIONS/CORDSETS to deliver reliable distributed and remote field power to machine controls. Mounts directly on the machine or production line eliminating the Input 3-PIN Connections Output 4-PIN Connections complexity and cost of unnecessary enclosures and excess wiring. Quick change connectors simplify connectivity for distributed I/O devices on Daniel Woodhead Turck industrial machinery. These Class 2 Listed, 24 Vdc power supplies are P/N 103000A01FXX0 P/N RSM46*M available in single and dual 100 Watt models and are perfect for automotive, packaging and automated distribution applications. or or Harting Harting CONTROL OUTPUT MODELS P/N 21 04 516 23XX P/N 21 04 516 14XX Designed for Control Power applications where a grounded power supply Connections to be provided by the user. output is required. XX is the length of the cordset in feet. Input connector: 3-PIN IP67 molded plug externally threaded with 7/8-16 UN mounting thread. * is the length of the cordset in meters Output connector: 4-PIN IP67 molded receptacle internally threaded XX is the length of the cordset in meters. with 7/8-16 UN mounting thread. ISOLATED OUTPUT MODELS DIMENSIONAL INFORMATION IN INCHES (MILLIMETERS) Designed for application where an isolated output from ground is required such as DeviceNet. 7.00 177.8 mm 7.00 177.8 mm 7.00 177.8 mm 3.27 in. 83.0 mm3.27 in. 83.0 mm3.27 in. 83.0 mm Input connector: 3-PIN IP67 molded plug externally threaded with 1.80 45.7 mm 1.80 45.7 mm 1.80 45.7 mm 6.52 165.6 mm 6.52 165.6 mm 6.52 165.6 mm 7/8-16 UN mounting thread. Output connector: 4-PIN IP67 molded receptacle internally threaded with 7/8-16 UN mounting thread. FEATURES IP66/67 rated versatile enclosure 24 Vdc, 100-240 Vac, up to four outputs at 3.8A Nominal Current (per pair for dual models) Class 2 Listed power supply for stand alone applications Can be mounted in any orientation without limitation Safety approved for AC and DC universal input Reliable operation from -40C to 60C without derating DC OK Green LED Worldwide approvals Side View Front View Side View Five year limited warranty Single 100 Watt Single and Dual 100 Watt Dual 100 Watt CERTIFICATIONS AND COMPLIANCES Listed, Ind. Control Equipment, E61379, ITE, E137632 - UL 508, CSA C22.2 No. 107.1 - UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition - Low Voltage Directive - IEC/EN60950-1, 2nd Edition RoHS Compliant For product information: www.solahd.com 1.800.377.4384 4.22 107.1 mm 4.73 120.1 mm 4.22 107.1 mm 5.45 138.4 mm TYP 4.73 120.1 mm 4.22 107.1 mm 5.45 138.4 mm TYP 4.73 120.1 mm 5.45 138.4 mm TYPCatalog Number Descriptions SCP 100S24X-CP1 SCP 102D24X-C02 SCP 100S24X-DVN1 SCP 102D24X-D02 Input Any voltage from 100 to 240 Vac Input Nominal Voltage -AC Range 85 - 264 Vac Universal Input 100 - 353 Vdc -DC Range Nominal Current 1 1.6A / 0.7A 2.4 - 1.4A / 2.4 - 0.7A Typ. <30A -Inrush current max. Power Factor Correction 2 0.95 50/60/400 Hz Frequency Output 35 V Power Back Immunity Overvoltage Protection 25-25.5 Vdc, autorecovery 24 Vdc Nominal Voltage Tolerance < +/-2% overall - Line Regulation < 0.5% - Load Regulation < 0.5% - Time & Temp. Drift < 1% Input Voltage Setting 24.5 V +/-1% 3 Ripple < 50 mVpp 3.8A 7.6A Total (3.8A max. per pair) Total Nominal Current Holdup Time > 50 ms (Full load, 100 Vac Input Tamb=+25oC) to 95% output voltage General 4 Emissions EN61000-6-3, EN61000-6-4, EN55011 Group 1, Class B, EN55022 Class B, EN61000-3-2, EN61000-3-3 EN61000-6-1, EN61000-6-2, EN55024, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, 4 Immunity IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEC61000-4-11, SEMI F47 Sag Immunity Storage: -40 to +85C, Operation: -40 to +60C full power with linear Storage: -40 to +85C, Operation: -25 to +60C full power with linear derating to half power from +60 to +70C. derating to half power from +60 to +70C. Temperature No forced air required. Operation up to 100% load permissible No forced air required. Operation up to 100% load permissible with sideways or front side up mounting orientation. with sideways or front side up mounting orientation. Humidity Up to 100% RH with condensation 0 to 3,000 m (0 to 10,000 ft.) Altitude 1 g non-operating swept sine over 10500 Hz (IEC 60068-2-6). Non-operating random vibration test: 1.87 g over 10500 Hz (IEC 60068-2-64). Oper- Vibration ating random vibration test: 0.15 g over 5100 Hz (IEC 60068-2-64) Shock Non-operating: 30 g peak, 18 ms half-sine pulse (IEC 68-2-27). Operating: 4 g peak, 22 ms half-sine pulse (IEC 68-2-27) 5 Year Limited Warranty Warranty >800,000 hours according to Telcoredia/Bellcore SR-332 Issue 1, >800,000 hr. according to Telcoredia/Bellcore SR-332 Issue 3, MTBF (Vin 120 V ac, Tamb = 40C) (Vin 120 V ac, ambient temp. = 40C) Protected against continuous short-circuit, continuous overload, Protected against continuous short-circuit, continuous overload, continu- and continuous open circuit. Protection NEC Class 2 (IEC536), General Protection/Safety ous open circuit. Protection Class 1. degree of protection IP66/IP67 versatile (IEC60529). Safety extra low voltage circuits: SELV (acc. EN60950). Safety extra low voltage circuits: SELV (acc. EN60950-1). DC OK LED Status Indicators - Visual Installation Fusing Internally fused, fuses not replaceable - Input - Output Electronically current limited to meet NEC Class 2 per UL1310 Mounting Chassis mounted using integral mounting tabs. Recommended Screw Size: M4 x 0.7. Tightening Torque: 1N-m An accessible disconnect device shall be installed external to the equipment. Input: 3-PIN IP67 molded plug (quick disconnect). Connections Output: 4-PIN IP67 molded receptacle (quick disconnect). Use UL 758 wire rated min. 24 V, VW-1/FT-1, max. 3.05 m. Case IP66/67 versatile ingress protection also meets UL50 Type 4X enclosure 0.39 in. (10 mm) all sides but base 1 in. (25 mm) all sides but base Min. Required Free Space H x W x D inches (mm) 4.73 x 7.00 x 1.80 (120.1 x 177.8 x 45.7) 4.73 x 7.00 x 3.27 (120.1 x 177.8 x 83.0) 2.2 (1.0) 3.3 (1.5) Weight - lbs (kg) 1. Input current ratings are specified with low input, line conditions, worst case efficiency values and power factor. 2. Power Factor Correction at 50/60 Hz only. 3. Ripple/noise is stated as typical AC values when measured with a 20 MHZ bandwidth scope and 50 Ohm termination. 4. Emissions and immunity are met by individual power supply modules. United States: 1.800.377.4384 Asia/Pacific: + 65.6891.7600 Australia: + 61.3.9721.0348 Brazil: So Paulo/SP + 55.11.2122.5777 Brazil: Camaari/BA + 55.71.3496.4427 Canada: + 1.888.765.2226 China: + 86.21.3418.3888 Europe: + 33.3.2254.1390 Mexico/Latin America: + 52.55.5809.5049 Middle East/Africa/India: + 971.4.811.8100 www.solahd.com Appleton Grp LLC d/b/a Appleton Group. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. 2015, Appleton Grp LLC. All rights reserved.