A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet KSK-GP/GR 560 Reed Switches
www.standexmeder.com
GP [or] GR 560
Reed Switches
Features: Miniature, General Purpose
Applications: Position Detector, Level Sensor, Tampering Switch
Markets: Industrial, HVAC, Security & Others
Part Description: K S K - GP [ o r ] GR 560 - XX XX
Pull-In Excitation
Contact QTY Contact Form Switch Model
(AT-Range)
1 A (SPST-NO) GP/GR 560 10 - 50
Contact Data Unit
Rated Power (max.)
10 W
Any DC combination of V&A not to exceed their individual max.s
Switching Voltage (max.)
200 V
DC or peak AC
Switching Current (max.)
1.0 A
DC or peak AC
Carry Current (max.)
1.5 A
DC or peak AC
Contact Resistance (max.)
100 mOhm
@ 0.5V & 10mA
Breakdown Voltage (min.)
300 V
DC or peak AC
Operating Time (max.)
0.5 ms
Incl. Bounce; Measured with 40% Overdrive
Release Time (max.)
0.1 ms
Measured with no Coil Excitation
Test Coil KMS-01
Insulation Resistance (min.)
10
10 Ohm
RH < 45%, 100 V Test Voltage
Capacitance (typ.)
0.2 pF
@ 10kHz across open Switch
USA: +1.866.782.6339 salesusa@standexmeder.com
Version 01
Europe: +49.7731.8399.0 info@standexmeder.com
27.01.2015
Asia: +86.21.37820625 salesasia@standexmeder.com
Modifications in the sense of technical progress are reserved. A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet KSK-GP/GR 560 Reed Switches
www.standexmeder.com
Dimensions (mm) KSK-GP/GR 560 Reed Switch
Overall Length (max.) 54.0
Glass Length (max.) 14.2
Glass Dia (max.) 2.3
Lead Dia. (max.) 0.6
Environmental Data Unit
Shock Resistance (max.)
100 g
1/2 sine wave duration 11ms
Vibration Resistance (max.) 50 g
Operating Temperature -40 to 125 C
Storage Temperature -50 to 155 C
Soldering Temperature (max.)
260 C
5 sec. max.
Life Test Data
Handling & Assembly Instructions
*Load increase reduces life expectancy of Reed Switches
Use proper lead clamping or heat sinking techniques to
prevent mechanical and/or heat stress to the glass seal
during bending, cutting, soldering, and welding
Mechanical shock as the result of dropping the reed switch
typically from a distance of greater than 12 may change its
magnetic sensitivity and/or destroy the switch
Any form of modification to the switch leads will alter its
magnetic sensitivity
Series resistor recommended for >5m cable length
Glossary Contact Material
NO = Normally Open Contacts
Form A
SPST = Single Pole Single Throw
NC = Normally Closed Contacts
Form B
SPST = Single Pole Single Throw
Changeover
Form C
SPDT = Single Pole Double Throw
USA: +1.866.782.6339 salesusa@standexmeder.com
Version 01
Europe: +49.7731.8399.0 info@standexmeder.com
27.01.2015
Asia: +86.21.37820625 salesasia@standexmeder.com
Modifications in the sense of technical progress are reserved.