A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
www.standexmeder.com
Series Datasheet MK01 Reed Sensors
MK01 Series
Reed Sensors
Features: Supplied in Tape & Reel, J-Lead, Excellent for Low Power Operations
Applications: On/Off Control Switch, Position Detection, Switching Element & Others
Markets: Appliance, Telecommunication, Security, Medical & Others
Part Description: MK 01 - X
Magnetic Sensitivity
B, C/H , D/I, E/K
Customer Options Switch Model
Unit
66 90
Contact Data
Rated Power (max.)
10 10 W
Any DC combination of V&A not to exceed their individual max.s
Switching Voltage (max.)
180 175 V
DC or peak AC
Switching Current (max.)
0.5 0.5 A
DC or peak AC
Carry Current (max.)
1.0 1.0 A
DC or peak AC
Contact Resistance (max.)
150 150 mOhm
@ 0.5V & 50mA
Breakdown Voltage (min.)
0.2 0.2 kVDC
According to EN60255-5
Operating Time (max.)
0.5 0.7 ms
Incl. Bounce; Measured with w/ Nominal Voltage
Release Time (max.)
0.05 1.5 ms
Measured with no Coil Excitation
Insulation Resistance (typ.)
10 9
10 10 Ohm
Rh<45%, 100V Test Voltage
Capacitance (typ.)
0.3 1.5 pF
@ 10kHz across open Switch
USA: +1.866.782.6339 salesusa@standexmeder.com
Version 01
Europe: +49.7731.8399.0 info@standexmeder.com
27.01.2015
Asia: +86.21.37820625 salesasia@standexmeder.com
Modifications in the sense of technical progress are reserved. A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
www.standexmeder.com
Series Datasheet MK01 Reed Sensors
Housing and Lead Specifications MK01 Reed Sensor
Housing Material Mineral Filled Epoxy
Case Color Black
Environmental Data Unit
Shock Resistance (max.)
30 g
1/2 sine wave duration 11ms
Vibration Resistance (max.) 20 g
Operating Temperature -20 to 130 C
Storage Temperature -35 to 130 C
Soldering Temperature (max.)
Life Test Data
260 C
5 sec. max.
*Load increase reduces life expectancy of Reed Switches
Handling & Assembly Instructions
Use proper lead clamping or heat sinking techniques to
prevent mechanical and/or heat stress during, soldering, and
welding
Mechanical shock as the result of dropping the reed sensor
may cause immediate or post-installation failure
Glossary Magnetic Sensitivity
Glossary Contact Form
Sensitivity Sensitivity
NO = Normally Open Contacts
AT Range
Form A
(Form A, B) (Form C)
SPST = Single Pole Single Throw
05 10 A
NC = Normally Closed Contacts
Form B
SPST = Single Pole Single Throw 10 15 B
15 20 C H
Changeover
Form C
20 25 D I
SPDT = Single Pole Double Throw
25 30 E K
30 35 F
35 - 40 G
USA: +1.866.782.6339 salesusa@standexmeder.com
Version 01
Europe: +49.7731.8399.0 info@standexmeder.com
27.01.2015
Asia: +86.21.37820625 salesasia@standexmeder.com
Modifications in the sense of technical progress are reserved.