A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
www.standexmeder.com
Series Datasheet MK24 Reed Sensors
MK24 Series
Reed Sensors
Features: Supplied in Tape & Reel, J-Lead, Excellent for Low Power Operations
Applications: On/Off Control Switch, Position Detection, Switching Element & Others
Markets: Appliance, Telecommunication, Security, Medical & Others
Part Description: MK 24 - 0 - X
Magnetic Sensitivity Lead Design
A, B, C, D, E 1, 2 , 3
Customer Options Switch Model
Unit
Contact Data 04
Rated Power (max.)
3 / 1* W
Any DC combination of V&A not to exceed their individual max.s
Switching Voltage (max.)
30 V
DC or peak AC
Switching Current (max.)
0.3 / 0.1* A
DC or peak AC
Carry Current (max.)
0.5 / 0.3* A
DC or peak AC
Contact Resistance (max.)
200 / 250* mOhm
@ 0.5V & 50mA
Breakdown Voltage (min.)
0.1 / 0.06* kVDC
According to EN60255-5
Operating Time (max.)
0.25 ms
Incl. Bounce; Measured with w/ Nominal Voltage
Release Time (max.)
0.15 ms
Measured with no Coil Excitation
Insulation Resistance (typ.)
10
10 Ohm
Rh<45%, 100V Test Voltage
Capacitance (typ.)
0.1 pF
@ 10kHz across open Switch
* Valid for Magnetic Sensitivity Range A
USA: +1.866.782.6339 salesusa@standexmeder.com
Version 01
Europe: +49.7731.8399.0 info@standexmeder.com
27.01.2015
Asia: +86.21.37820625 salesasia@standexmeder.com
Modifications in the sense of technical progress are reserved. A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
www.standexmeder.com
Series Datasheet MK24 Reed Sensors
Housing and Lead Specifications MK24 Reed Sensor
Housing Material Mineral Filled Epoxy
Case Color Black
Lead design 1 Flat, straight leads for PCB slot mounting
Lead design 2 Flat, bent SMD leads
Lead design 3 J-Lead
Environmental Data Unit
Shock Resistance (max.)
30 g
1/2 sine wave duration 11ms
20 g
Vibration Resistance (max.)
Operating Temperature -40 to 130 C
Storage Temperature -50 to 130 C
Handling & Assembly Instructions
Soldering Temperature (max.)
260 C
5 sec. max.
Use proper lead clamping or heat sinking
techniques to prevent mechanical and/or heat
Glossary Contact Form
stress during, soldering, and welding
NO = Normally Open Contacts
Form A Mechanical shock as the result of dropping the reed
SPST = Single Pole Single Throw
sensor may cause immediate or post-installation
NC = Normally Closed Contacts
failure
Form B
SPST = Single Pole Single Throw
Reflow Soldering Conditions according to JEDEC
Changeover
norm J-STD-020D.1
Form C
SPDT = Single Pole Double Throw
Glossary Magnetic Sensitivity
Life Test Data
*Load increase reduces life expectancy of Reed Switches
Sens. A B C D E F G
AT 05-10 10-15 15-20 20-25 25-30 30-35 35-40
USA: +1.866.782.6339 salesusa@standexmeder.com
Version 01
Europe: +49.7731.8399.0 info@standexmeder.com
27.01.2015
Asia: +86.21.37820625 salesasia@standexmeder.com
Modifications in the sense of technical progress are reserved.