SAFETY DATA SHEET SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Trade name or designation Ltzinn ECOLOY TC of the mixture Synonyms Ltzinn ECOLOY TC (Sn, Cu 0,5-0,9%) * Ltzinn ECOLOY TC 300 (Sn, Cu 2,5-3,5%) Issue date 02-September-2013 Version number 1.0 Revision date 19-September-2013 Supersedes date 09-September-2013 Product use Consumer use 1.2. Relevant identified uses of the substance or mixture and uses advised against Identified uses Metal alloy for soft solder Uses advised against None known 1.3. Details of the supplier of the safety data sheet Company name STANNOL GmbH Oskarstr. 3-7 Address 42283 Wuppertal Germany Contact person Dr. Sven Mnninghoff Telephone number +49 (0) 202 585-129 Fax +49 (0) 202 585 155 sven.moenninghoff stannol.de e-mail Contact person HSE-BBS bayer.com +49 (0) 202 585 129 (8:00 a.m. 4:00 p.m. (MET)) Emergency telephone number SECTION 2: Hazards identification 2.1. Classification of the substance or mixture The mixture has been assessed and/or tested for its physical, health and environmental hazards and the following classification applies. Classification according to Directive 67/548/EEC or 1999/45/EC as amended Remark: The classification for this article has been derived with the use of the regulations for mixtures. Hazard summary Physical hazards Not classified for physical hazards. Health hazards Not classified for health hazards. Environmental hazards Not classified for hazards to the environment. Specific hazards Not available. Main symptoms Not available. 2.2. Label elements Label according to Directive 67/548/EEC or 1999/45/EC as amended EC number - EC label Not available. R-phrases Not available. Not available. S-phrases Authorisation number Not available. Supplemental label information Remark: As an article, this product has not to be labelled pursuant to current EU-regulation. 2.3. Other hazards Not assigned. SECTION 3: Composition/information on ingredients 3.2. Mixtures Material name: Ltzinn ECOLOY TC SDS UK 1 / 6 8460 Version No.: 1.0 Revision date: 19-September-2013 Issue date: 02-September-2013General information CAS-No. / EC No. REACH Registration No. INDEX No. Chemical name % Notes Tin 96.5 - 99.9 7440-31-5 - - 231-141-8 - Classification: DSD: - CLP: Copper Metal 0.5 - 3.5 7440-50-8 - - 231-159-6 Classification: DSD: - CLP: - CLP: Regulation No. 1272/2008. DSD: Directive 67/548/EEC. PBT: persistent, bioaccumulative and toxic substance. vPvB: very persistent and very bioaccumulative substance. : This substance has been assigned Community workplace exposure limit(s). SECTION 4: First aid measures General information Not available. 4.1. Description of first aid measures Inhalation Move to fresh air. Call a physician if symptoms develop or persist. Skin contact Rinse skin with water/shower. Get medical attention if irritation develops and persists. For hot product: Immediately immerse in or flush affected area with large amounts of cold water to dissipate heat. Cover with clean cotton sheeting or gauze and get prompt medical attention. Eye contact Remove contact lenses, if present and easy to do. Rinse immediately with plenty of water, also under the eyelids. Get medical attention if irritation develops and persists. Ingestion Rinse mouth. Get medical advice/attention if you feel unwell. 4.2. Most important symptoms Not available. and effects, both acute and delayed 4.3. Indication of any Treat symptomatically. Symptoms may be delayed. immediate medical attention and special treatment needed SECTION 5: Firefighting measures General fire hazards Not available. 5.1. Extinguishing media Suitable extinguishing Use fire-extinguishing media appropriate for surrounding materials. media Unsuitable extinguishing Water, CO2 or Foam media 5.2. Special hazards arising The product itself does not burn. Hot melt from the substance or mixture 5.3. Advice for firefighters Special protective Firefighters should wear full protective clothing including self contained breathing apparatus. equipment for firefighters Special fire fighting Water runoff can cause environmental damage. procedures SECTION 6: Accidental release measures 6.1. Personal precautions, protective equipment and emergency procedures For non-emergency Keep unnecessary personnel away. Ensure adequate ventilation. Wear appropriate protective personnel equipment and clothing during clean-up. For emergency responders Not available. 6.2. Environmental precautions Contact local authorities in case of spillage to drain/aquatic environment. Avoid discharge into drains, water courses or onto the ground. 6.3. Methods and material for Remove material, as much as possible, using mechanical equipment. Absorb with earth, sand or containment and cleaning up other non-combustible material and transfer to containers for later disposal. For waste disposal, see section 13. Material name: Ltzinn ECOLOY TC SDS UK 2 / 6 8460 Version No.: 1.0 Revision date: 19-September-2013 Issue date: 02-September-2013