Desktop SYS1546-T3 series 36W Country of Origin : China Operating Temperature : 0~40 C Dimension : 99 x 50 x 33 mm Efficiency level (ErP) : VI Approvals / Marks : BIS Specifications Voltage DC Loading Max. Power Ripple / Noise Connector Model V A W mV p-p mm SYS1546-3612-T3 12 0~3.00 36 180 2.1x5.5x11 SYS1546-3615-T3 15 0~2.40 36 200 2.1x5.5x11 SYS1546-3618-T3 18 0~2.0 36 240 2.1x5.5x11 SYS1546-3619-T3 19 0~1.89 36 240 2.1x5.5x11 SYS1546-3624-T3 24 0~1.5 36 300 2.1x5.5x11 Features: Available in 2 inlet versions: C7 (T2) C13(T3) Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement Regulated Output With Low Ripple Noise Safety Agency Requirements and EMI/EMS Certified Private Label Marking Available Modified and Custom Design Available 2 Years Warranty OUTPUT EMC Turn delay 5000ms max AC low line input output full load Meet EN550022 class B, FCCpart 15 Sub part B class B Hold up time 5ms min AC nominal input output full load (>half cycle) EN 60950-1:2006+All LVD2006/95/EC IEC 60950-1:2005+A1+A2 Meet CEC,DOE,ERP,MEPS Level VI Efficiency (Normal) 115v/60HZ,230V/50HZ SAFETY 0.4V dv max At AC nominal input loading from 20%load to UL GS CB CE FCC CCC BSMI PSE EK-Mark (only for 3612) SAA RCM NOM (only 80%load Transient response for 3612) EAC BIS (only for 3612/3615) S-MARK (dv,tmax) 16ms tmax Dynamic rise time 10us max,duty 40ms max,Dynamic load step is slew rate of 0.5A/us OTHERS Power out.Limit Peak 40w Dielectric Strength(Hi-pot) Primary to Secondary:3000VAC 10mA/60S Burn in limit Full load 2 Hours M.T.B.F 500,000 Calculated Hours at 25C, by Telcordia SR-332 Less than 0.075W ms max. At AC nominal input output min Power consumption Cable Length 1370mm (4.5 feet) standard cable or as required load PLD INPUT Line power surge Line voltage SAG-more info on request (power line disturbance) Voltage (90~264)VAC Cooling method Natural Convection Cooling Frequency (47~63)hz Housing material PC Current 1.5A rms AC low line input and DC output full load Temperature coefficient: <0.5%/ Inrush Surge Current 40/60A max power supply cold start,ambient temperature (cold start) 25C 115Vac/230Vac nominal AC input ENVIRONMENT leakage current 0.25mA Max Temperature Operating: 0~40 / Storage: 5%~90%RH non condensing PROTECTION Operating: 8%~90%RH / Storage: 5%~95% RH non condens- The power supply will self-protect any output to ground & auto Humidity Over current/ ing recovery when abnormal circuit faults remove. An output short Short protection circuit is defined as any output impedance less than 0.1 ohms. WEIGHT Over Voltage The power supply will be auto recovered when faults remove NW: 166g/pc F1:1A 250V Fuse The power supply shall be protected Input protection GW: 10.5kg/box against power line surges and any abnormal condition The power supply is provided with no load operation to prevent No Load protection PACKING the power supply and system from damage. Protection class I, (ITU-T K.21 Surge 6KV on request) PE plastic bag 60 pcs/1 box www.sunny-euro.com Desktop SYS1546-T3 series 36W Mechanical case specification: Cable specification: www.sunny-euro.com