MAXIMUM RATINGS
Rating Symbol 1N4001 1N4002 1N4003 1N4004 1N4005 1N4006 1N4007 Unit
Peak Repetitive Reverse Voltage V 50 100 200 400 600 800 1000 V
RRM
Working Peak Reverse Voltage V
RWM
DC Blocking Voltage V
R
NonRepetitive Peak Reverse Voltage V 60 120 240 480 720 1000 1200 V
RSM
(halfwave, single phase, 60 Hz)
RMS Reverse Voltage V 35 70 140 280 420 560 700 V
R(RMS)
Average Rectified Forward Current I 1.0 A
O
(single phase, resistive load,
60 Hz, T = 75C)
A
NonRepetitive Peak Surge Current I 30 (for 1 cycle) A
FSM
(surge applied at rated load conditions)
Operating and Storage Junction T 65 to +175 C
J
Temperature Range T
stg
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Indicates JEDEC Registered Data
THERMAL CHARACTERISTICS
Rating Symbol Max Unit
Maximum Thermal Resistance, JunctiontoAmbient R Note 1 C/W
JA
ELECTRICAL CHARACTERISTICS
Rating Symbol Typ Max Unit
Maximum Instantaneous Forward Voltage Drop, (i = 1.0 Amp, T = 25C) v 0.93 1.1 V
F J F
Maximum FullCycle Average Forward Voltage Drop, (I = 1.0 Amp, T = 75C, 1 inch leads) V 0.8 V
O L F(AV)
Maximum Reverse Current (rated DC voltage) I A
R
(T = 25C) 0.05 10
J
(T = 100C) 1.0 50
J
Maximum FullCycle Average Reverse Current, (I = 1.0 Amp, T = 75C, 1 inch leads) I 30 A
O L R(AV)
Indicates JEDEC Registered Data