CUS200LD Series 79-153W Single Output Power Supplies Features Convection or Conduction Cooled Up to 206W Peak Power Capability Low 31mm Height -40C Ambient temperature Start Up Key Market Segments & Applications Speci cations Model CUS200LD (1) AC Input Voltage VAC 85 - 265VAC Input Frequency Hz 47 - 63Hz Inrush Current (cold start) A 20A at 115VAC, 40A at 230VAC (2) Power Factor - Meets EN61000-3-2 (Typical PF 0.95/0.9) Input Current A Varies by model, please see detailed speci cation on website Temperature Coe cient %/C <0.02%/C Overcurrent Protection - > 101% of peak current rating (3) Overvoltage Protection V See model selector Hold Up Time (115 / 230V input) ms 20ms typical Leakage Current mA <0.75mA at 265VAC, 60Hz Ripple and Noise % 3.3-7.5V: 120mV, 12-24V: 150mV, 28-48V: 200mV Line and Load Regulation % See model selector Remote Sense - No -25 to +70C. Start up at -40C Operating Temperature C Convection cooled: Derate linearly to 40% load from +40 to +70C Conduction cooled: Derate linearly to 40% load from +45 to +70C Storage Temperature C -40 to +85C Humidity (non condensing) %RH 10 - 95%RH (Operating & Storage) Cooling - Convection or Conduction Cooled (Mounted on a 2mm thick aluminium plate 400x400mm) Withstand Voltage - Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC Isolation Resistance M >100M at 25C & 70%RH, Output to Ground 500VDC 2 Vibration (non operating) - 10 - 55Hz: 19.6m/s constant sweep 1 min X, Y, Z for 1 hour 2 Shock - < 196.1 m/s (20G) Immunity - IEC61000-4-2 (lv 2, 3), -3 (lv3), -4 (lv 3), -5 (lv3, 4), -6 (lv 3), -8 (lv 4), -11 Safety Agency Certi cations - IEC/UL/CSA/EN 62368-1, IEC/UL/CSA/EN 60950-1, CE Mark Conducted & Radiated EMI - EN55011-B, EN55032-B, FCC Class B Weight (Typ) g 430 Size (LxWxH) mm (in) 160 x 62 x 31mm (6.3 x 2.44 x 1.22) Warranty yrs Three Years Notes: See speci cation for conditions and test methods (1) 4.2V model: Derate linearly to 90% load from 115 to 85VAC input. 5-48V models: Derate linearly to 80% load from 115 to 85VAC input (2) 115 / 230VAC input (3) Cycle AC to reset CUS200LD Series Model Selector Adjust Max Current Max Power Max Current Max Power Peak Load Line (4) Output Range Convection Convection Conduction Conduction Current Reg Reg Efficiency (5) Model Voltage (V) (A) (W) (A) (W) (A) (mV) (mV) Overvoltage (typ) % CUS200LD-3 3.3V 2.97 - 3.63V 24A 79.2W 30A 99W 40A 26mV 13mV 3.8 - 5.44V 82 / 83% CUS200LD-4 4.2V 3.78 - 4.62V 24A 100.8W 30A 126W 40A 33mV 16mV 4.83 - 6.51V 85 / 87% CUS200LD-5 5V 4.5 - 5.5V 24A 120W 30A 150W 40A 40mV 20mV 5.75 - 7.5V 87 / 89% CUS200LD-7R5 7.5V 6.375 - 8.25V 16A 120W 20A 150W 26.6A 60mV 30mV 8.63 - 10.87V 88 / 90% CUS200LD-12 12V 10.8 - 13.2V 10A 120W 12.5A 150W 16.7A 96mV 48mV 13.8 - 17.4V 87 / 89% CUS200LD-15 15V 13.5 - 16.5V 8A 120W 10A 150W 13.4A 120mV 60mV 17.25 - 21.75V 87 / 89% CUS200LD-24 24V 21.6 - 26.4V 5A 120W 6.3A 151.2W 8.4A 192mV 96mV 27.6 - 34.8V 87 / 89% CUS200LD-28 28V 25.2 - 30.8V 4.3A 120.4W 5.4A 151.2W 7.2A 224mV 112mV 32.2 - 40.6V 87 / 90% CUS200LD-48 48V 43.2 - 52.8V 2.5A 120W 3.15A 151.2W 4.2A 384mV 192mV 55.2 - 69.6V 88 / 90% Notes: See speci cation for conditions and test methods (4) Convection cooling: Peak current for less than 10 seconds, with a duty cycle of <35% Conduction cooling: Peak current for less than 5 seconds, with a duty cycle of <35% (5) 115 / 230VAC input. Conduction cooled ratings Outline Drawing For additional information, please visit