DENSEI-LAMBDA HWS80 SPECIFICATIONS A233-01-01A HWS80 HWS80 HWS80 HWS80 HWS80 HWS80 MODEL ITEMS -3 -5 -12 -15 -24 -48 3.3 5 12 15 24 48 1 Nominal Output Voltage V 2 Maximum Output Current A 16 16 6.7 5.4 3.4 1.7 52.8 80 80.4 81 81.6 81.6 3 Maximum Output Power W 4 Efficiency (Typ) (*1) 100VAC % 77 82 82 82 83 84 200VAC % 79 85 85 85 85 86 5 Input Voltage Range (*2) - 85 ~ 265VAC (47 ~ 63Hz) or 120 ~ 370VDC 6 Input Current (100/200VAC)(Typ) (*1) A 0.72/0.36 1.04/0.52 7 Inrush Current(Typ) (*3) - 14A at 100VAC, 28A at 200VAC, Ta=25C, Cold Start 8 PFHC - Built to meet IEC61000-3-2 0.98/0.90 0.99/0.95 9 Power Factor (100/200VAC)(Typ) (*1) - 10 Output Voltage Range V 2.97~3.96 4.0~6.0 9.6~14.4 12.0~18.0 19.2~28.8 38.4~52.8 0<Ta<70C 120 120 150 150 150 200 11 Maximum Ripple & Noise mV (*4) -10<Ta<0C mV 160 160 180 180 180 240 20 20 48 60 96 192 12 Maximum Line Regulation (*5) mV 13 Maximum Load Regulation (*6) mV 40 40 96 120 192 384 14 Temperature Coefficient - Less than 0.02% / C 15 Over Current Protection (*7) A 16.8 ~ 16.8 ~ 7.04 ~ 5.67 ~ 3.57 ~ 1.79 ~ 4.13~4.95 6.25~7.25 15.0~17.4 18.8~21.8 30.0~34.8 55.2~64.8 16 Over Voltage Protection (*8) V 17 Hold-up Time (Typ) (*9) - 20ms 18 Leakage Current (*10) - Less than 0.5mA. 0.2mA(Typ) at 100VAC / 0.4mA(Typ) at 230VAC 19 Remote Sensing - Possible 20 Parallel Operation - - 21 Series Operation - Possible 22 Operating Temperature (*11) - -10 ~+70C (-10 ~+50C:100%,+60C:60%,+70C:20%) 23 Operating Humidity - 30 ~ 90%RH (No dewdrop) 24 Storage Temperature - -30 ~ +85C 25 Storage Humidity - 10 ~ 95%RH (No dewdrop) 26 Cooling - Convection Cooling 27 Withstand Voltage - Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA) Output - FG : 500VAC (100mA) for 1min 28 Isolation Resistance - More than 100M at 25C and 70%RH Output - FG : 500VDC 29 Vibration - At no operating, 10 ~ 55Hz (Sweep for 1min) 2 19.6m/s Constant, X,Y,Z 1hour each. 2 30 Shock (In package) - Less than 196.1m/s 31 Safety (*12) - Approved by UL60950-1, CSA60950-1, EN60950-1, EN50178 Built to meet UL508, DENAN 32 Line DIP - Built to meet SEMI-F47 (200VAC Line only) 33 Conducted Emission - Built to meet EN55011/EN55022-B, FCC-B, VCCI-B 34 Radiated Emission - Built to meet EN55011/EN55022-B, FCC-B, VCCI-B 35 Immunity - Built to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3), -5(Level 3,4), -6(Level 3), -8(Level 4), -11 36 Weight(Typ.) - 450g 37 Size (W x H x D) mm 28 x 82 x 160 ( Refer to Outline Drawing ) *Read instruction manual carefully, before using the power supply unit. =NOTES= *1. At 100/200VAC, Ta=25C and maximum output power. *2. For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 ~ 240VAC(50/60Hz). *3. Not applicable for the in-rush current to Noise Filter for less than 0.2ms. *4. Measure with JEITA RC-9131A probe, Bandwise of scope :100MHz. *5. 85 ~ 265VAC , constant load. *6. No load-Full load, constant input voltage. *7. Constant current limit and Hiccup with automatic recovery. Not operate at over load or dead short condition for more than 30seconds. *8. OVP circuit will shutdown output, manual reset (Re power on). *9. At 100/200VAC , nominal output voltage and maximum output current. *10. Measured by the each measuring method of UL,CSA,EN and DENAN(at 60Hz). *11. Ratings - Derating at standard mounting. - Load (%) is percent of maximum output power or maximum output current, whichever is greater. - As for other mountings, refer to derating curve (A233-01-02 ). *12. As for DENAN, built to meet at 100VAC.DENSEI-LAMBDA HWS80 OUTPUT DERATING A233-01-02 LOAD(%) Ta(C) MOUNTING A MOUNTING B,C,D -10 ~+40 100 100 100 80 50 60 60 60 20 20 70 OUTPUT DERATING CURVE 120 100 80 MOUNTING A 60 MOUNTING B,C,D 40 20 0 -10 0 10 20 30 40 50 60 70 80 Ta(C) MOUNTING A MOUNTING B MOUNTING C MOUNTING D DON T USE (STANDARD MOUNTING) LOAD(%)