Embedded Power for Business-Critical Continuity Rev. 10.15.09 163 NPS40-M Series 1 of 3 NPS40-M Series 60 Watts Total Power: 40 - 60 Watts Input Voltage: 90 - 264 VAC 127 - 300 VDC of Outputs: Single Special Features Electrical Specifications Input Medical and ITE Safety Approvals Universal input Input ra nge: 90 - 264 VAC (wide range) 127-300 Vdc Less than 1U high Frequency: 47-440 Hz 2 x 4 footprint Remote sense Inrush current: < 50 A peak 230 VAC, cold start 25 C Overload and short circuit Input power: < 74 Watts protection Adjustable output voltage Efficiency: 87% average (as per Energy Star 2.0 standard) (NPS42-M, 80%) High efficiency EMI/RFI: FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B con- High MTBF ducted, VDE0878PT3 Class B conducted Built in EMI filter Safety ground leakage 275uA 50/60 Hz 264 VAC input (CISPR 22 Class B) current: International Efficiency Level V, Output Energy Star 2.0 & CeC compliant Maximum power: 45W for convection (NPS42-M, 40 W). 60 W with 200LFM forced air (except NPS42-M) (NPS42-M, 55 W) Less than 300 mW no-load power consumption Adjustment range: 20% minimum 0C to +80C operation Hold-up time: 10/20 ms 115/230 VAC input line Input power < 74 watts Overload protection: Short circuit protection on all outputs. Case overload protected Complies with EN61000 -3-2 110-160% of normal rating UL Class I approved LPX50 enclosure kit available Overvoltage protection: 30-50% above nominal output Dual AC fuses Remote sense: Compensated for 0.5 V lead drop max. Will operate without remote sense connected. Reverse connection protected. Safety TUV: 60950, 60601-1 UL: 60950, 60601-1 CSA: 60950, 60601-1 NEMKO: 60950, 60601-1 CB: Certificate and report CE: Mark (LVD) CQC: Mark Embedded Power for Business-Critical Continuity Rev. 10.15.09 163 NPS40-M Series Environmental Specifications 2 of 3 Operating temperature: 0 to 50 C ambient derate each output as 2.5% per degree from 50 to 80 C. -20 C start up Storage temperature: -45 C to +85 C Electromagnetic susceptibility: Designed to meet EN61000-4 -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating non-condensing 10% to 90% RH Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF demonstrated: > 550,000 hours at full load and 25 C ambient conditions Mechanical Drawing BARCODE 4.00 0.86 VR1 (101.6) (21.8 max) 3.73 OUTPUT VOLTAGE M1 (94.6) ADJUST POT GND TAB (CN1) PIN 1 PIN 1 PIN 3 PIN 6 INPUT CONNECTOR (SK1) 6 PINS OUTPUT M2 0.16 (4.0) MOUNTING HOLE MODEL LABEL ROHS LABEL CONNECTOR (4 PLACES) (SK2) 0.197 (5.0) MINIMUM STANDOFF HEIGHT 1.72 1.00 (43.8) (25.4) 2.00 (50.8)