JWS Series Single Output Industrial Power Supplies Features 5 Year Warranty Power factor Corrected Approved to VDE0160 Machinery Directive Universal Input (85 - 265VAC) Level B EMI Key Market Segments & Applications Factory Automation Process Control, NC-Machining, Automotive, Packaging Equipment, Materials Handling, Chemical Processing, Robots Test & Measurement Burn-in & Test, Automated Test, Instrumentation, Measurement, Detection Not recommended for new designs - see HWS series Speci cations Model JWS50 JWS75 JWS100 JWS150 JWS300 JWS600 Input Voltage range - 85 - 265VAC (47 - 63Hz) or 120 - 330VDC Inrush Current (100 / 200VAC) A 14 / 28 25 / 50 20 / 40 Power Factor - Meets EN61000-3-2 Temperature Coe cient - <0.02%/C Overcurrent Protection - >105% Overvoltage Protection V Yes Hold Up Time (Typ) ms 20 Leakage Current (max) mA 0.75 Remote Sense - No Yes Remote On / O - Specify as Option /R Standard AC Power Fail - Not Available Standard Parallel Connection - Not Available Avail. JWS300 & 600 only Operating Temp. (open frame) - -10C~+60C, derate linearly to 60% load from 50C~60C Operating Temp. (with cover) - -10C~+50C, derate linearly to 60% load from 40C~50C (JWS50-150) - -10C~+65C, derate linearly to 55% load from 50C~65C (JWS300-600) Storage Temperature - -30 to +85C Operating Humidity (1) - 30 - 90% RH 10 - 90% RH Storage Humidity (1) - 10 - 95% RH Cooling - JWS50 - JWS150 Convection, JWS300 & JWS600 Internal fan Withstand Voltage - Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), - Output to Ground 500VAC (100mA) for 1 min. Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC 2 Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s constant X, Y, Z 1 hour 2 Shock - < 196.1 m/s Safety Agency Approvals - UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, VDE0160, CE Mark, Built to meet DENTORI Conducted & Radiated EMI - EN55011 / EN55022-B, FCC Class B, VCCI-B Recommended EMI Filter - MAW1202-22 MAW1203-22 MB1210 MB1216 Weight (Typ) g 350 450 650 850 1900 3000 Size (WxHxD) mm See side 2 Warranty - Five Years (1) Non condensing Last Time Buy November 2019 1-800-526-2324 www.us.tdk-lambda.com/lp/ 11 Disclaimer: us.tdk-lambda.com/lp/legal.htmJWS Series Model Derating* JWS Outline Drawing Adjust Max Load Line Ripple E . Model Voltage Range Curr. Reg mV Reg mV Noise (typ)% JWS300-2 2.0V 1.8 - 2.4 60 20 20 120 60 JWS600-2 2.0V 1.8 - 2.4 120 30 20 120 61 JWS50-3/A 3.3V 2.85 - 3.63 10 40 20 120 65 JWS75-3/A 3.3V 2.85 - 3.63 15 40 20 120 67 JWS100-3/A 3.3V 2.85 - 3.63 20 40 20 120 67 JWS150-3/A 3.3V 2.85 - 3.63 30 40 20 120 67 JWS300-3 3.3V 2.97 - 3.96 60 20 20 120 68 JWS600-3 3.3V 2.97 - 3.96 120 30 20 120 70 JWS50-5/A 5.0V 4.5 - 5.5 10 40 20 120 74 JWS75-5/A 5.0V 4.5 - 5.5 15 40 20 120 74 JWS100-5/A 5.0V 4.5 - 5.5 20 40 20 120 75 JWS150-5/A 5.0V 4.5 - 5.5 30 40 20 120 75 JWS300-5 5.0V 4.5 - 6.0 60 20 20 120 74 JWS600-5 5.0V 4.5 - 6.0 120 30 20 120 75 JWS100-6/A 6.0V 5.4 - 6.6 16.7 48 24 120 75 JWS300-6 6.0V 5.4 - 7.2 50 36 24 150 74 JWS600-6 6.0V 5.4 - 7.2 100 36 24 120 75 JWS600-8 8.0V 7.2 - 9.6 68 48 32 150 77 JWS50-9/A 9.0V 8.1 - 9.9 5.6 76 36 150 74 JWS100-9/A 9.0V 8.1 - 9.9 11.2 72 36 150 75 JWS300-9 9.0V 8.1 - 10.8 34 54 36 150 76 JWS600-9 9.0V 8.1 - 10.8 68 54 36 150 77 JWS50-12/A 12.0V 10.8 - 13.2 4.3 96 48 150 76 JWS75-12/A 12.0V 10.8 - 13.2 6.3 96 48 150 76 JWS100-12A 12.0V 10.8 - 13.2 8.5 96 48 150 76 JWS150-12/A 12.0V 10.8 - 13.2 13 96 48 150 77 JWS300-12 12.0V 10.8 - 14.4 27 48 48 150 76 JWS600-12 12.0V 10.8 - 14.4 53 72 48 150 80 JWS50-15/A 15.0V 13.5 - 16.5 3.5 120 60 150 77 JWS75-15/A 15.0V 13.5 - 16.5 5 120 60 150 77 JWS100-15/A 15.0V 13.5 - 16.5 7 120 60 150 77 JWS150-15/A 15.0V 13.5 - 16.5 10 120 60 150 78 JWS300-15 15.0V 13.5 - 18.0 22 60 60 150 77 JWS600-15 15.0V 13.5 - 18.0 43 90 60 150 81 JWS50-24/A 24.0V 21.6 - 26.4 2.2 150 96 150 79 JWS75-24/A 24.0V 21.6 - 26.4 3.2 150 96 150 79 See website for detailed drawing. JWS100-24/A 24.0V 21.6 - 26.4 4.5 150 96 150 79 JWS150-24/A 24.0V 21.6 - 26.4 6.5 150 96 150 80 JWS300-24 24.0V 21.6 - 28.8 14 144 96 150 80 JWS600-24 24.0V 21.6 - 28.8 27 144 96 150 82 JWS50-28/A 28.0V 25.2 - 30.8 2 160 112 150 79 JWS100-28/A 28.0V 25.2 - 30.8 3.6 160 112 150 79 Dimensions Table JWS150-28/A 28.0V 25.2 - 30.8 5.5 160 112 150 80 JWS300-28 28.0V 25.2 - 33.6 12 168 112 150 80 Height (H) Width (W) Depth (D) JWS600-28 28.0V 25.2 - 33.6 23 168 112 150 82 JWS50 1.45 3.35 6.25 JWS50-48/A 48.0V 43.2 - 52.8 1.1 240 192 200 79 JWS75-48/A 48.0V 43.2 - 52.8 1.6 240 192 200 79 JWS75 1.65 3.62 6.88 JWS100-48/A 48.0V 43.2 - 52.8 2.1 240 192 200 79 JWS100 1.97 3.62 7.40 JWS150 2.56 3.62 7.80 JWS150-48/A 48.0V 43.2 - 52.8 3.3 240 192 200 80 JWS300-48 48.0V 43.2 - 52.8 6.5 288 192 350 80 JWS300 3.62 4.72 7.48 JWS600-48 48.0V 43.2 - 52.8 13 288 192 350 83 JWS600 3.62 6.29 7.90 Other Industrial Products Options HWS 15W to 1800W Single output Su x Description LZSA 500 to 1500W Single output Blank Screw terminals, no cover (JWS50 - JWS150) DLP/DSP/DPP 10 to 480W DIN Rail Mount /A* Screw terminals, cover (JWS50 - JWS150) /B Molex terminals, no cover (JWS50 & JWS75) /C Molex terminals, cover (JWS50 & JWS75) /R Remote On / O (JWS50 - JWS150) For Additional Information, please visit us.tdk-lambda.com/lp/products/jws-series.htm Example JWS50-5/RA Note: * Standard US stock item. Last Time Buy November 2019 Not recommended for new designs - see HWS series 1-800-526-2324 www.us.tdk-lambda.com/lp/ 12 Revision A8: Feb 2019