JWS-P Series Single Output Peak Power Industrial Power Supplies Features 5 Year Warranty Power factor Corrected Approved to VDE0160 Machinery Directive Universal Input (85 - 265VAC) 200% Peak Power Capability for 10 seconds Key Market Segments & Applications Factory Automation Process Control, NC-Machining, Automotive, Packaging Equipment, Materials Handling, Chemical Processing, Robots Test & Measurement Burn-in & Test, Automated Test, Instrumentation, Measurement, Detection Not recommended for new designs - see HWS series Speci cations Model JWS70P JWS120P JWS240P JWS480P Input Voltage range - 85 - 265VAC (47 - 63Hz) or 120 - 330VDC Inrush Current (100/200VAC) A 14 / 28 25 / 50 20 / 40 Input Current (Typ) A 1.0 / 0.5 1.6 / 0.8 3.2 / 1.6 6.4 / 3.2 Power Factor Meets EN61000-3-2 Temperature Coe cient <0.02%/C Overcurrent Protection - >102% Overvoltage Protection V Yes Hold Up Time (Typ) ms 20 Leakage Current (max) mA 0.75 Remote Sense - Yes Remote On / O - No Yes AC Power Fail - No Yes Operating Temperature - -10C~+60C,derate linearly -10C~+65C, derate linearly to 60% load from 50C~60C to 55% load from 50C~65C Storage Temperature - -30 to +85C Operating Humidity (1) - 30 - 90% RH Storage Humidity (1) - 10 - 95% RH Cooling - Convection Internal Fan Withstand Voltage - Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC (100mA) for 1 min Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC 2 Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s constant X, Y, Z 1 hour 2 Shock - < 196.1 m/s Safety Agency Approvals - UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, VDE0160, CE Mark, Built to meet DENTORI Conducted & Radiated EMI - EN55011 / EN55022-B, FCC Class B, VCCI-B Weight (Typ) g 700 900 1900 3000 Recommended EMI Filter - MAW1202-22 MAW1205-22 MB1210 Size (WxHxD) mm Warranty - Five Years (1) Non condensing Last Time Buy November 2019 1-800-526-2324 www.us.tdk-lambda.com/lp/ 11 Disclaimer: us.tdk-lambda.com/lp/legal.htmJWS-P Series Model Selector Adjust Average Peak Ripple Model Voltage Range Current (A) Current (A) *1 Load Reg (mV) Line Reg (mV) Noise (mV) E ciency (typ) % JWS70P-24 24V 21.6 - 26.4 3 6 192 96 240 80 JWS120P-24 24V 21.6 - 26.4 5 10 192 96 240 80 JWS240P-24 24V 21.6 - 28.8 10 20 192 96 240 80 JWS480P-24 24V 21.6 - 28.8 20 40 192 96 240 80 JWS240P-36 36V 32.4 - 43.2 6.65 13.3 288 144 360 80 JWS70P-48 48V 43.2 - 52.8 1.5 3 384 192 480 80 JWS120P-48 48V 43.2 - 52.8 2.5 5 384 192 480 80 JWS240P-48 48V 43.2 - 52.8 5 10 384 192 480 80 JWS480P-48 48V 43.2 - 52.8 10 20 384 192 480 80 Note *1: Peak current for up to 10 seconds with a 50% duty cycle Dimensions Table JWS Outline Drawing Height (H) Width (W) Depth (D) JWS70P 1.97 3.62 7.40 JWS120P 2.56 3.62 7.80 JWS240P 3.62 4.72 7.48 JWS480P 3.62 6.29 7.90 Other Industrial Products HWS 15 to 1500W Single output JWS & JWT 50W to 600W Single and triple output JFS 500W to 2000W Single output DLP/DSP/DPP 10 to 480W DIN Rail Mount For Additional Information, please visit us.tdk-lambda.com/lp/products/jws-series.htm See website for detailed drawing. Last Time Buy November 2019 Not recommended for new designs - see HWS series 1-800-526-2324 www.us.tdk-lambda.com/lp/ 12 Revision A8: Feb 2019