Noise Filter MYB-SERIES m Features MYB-1220-33 (1) High attenuation effect against high voltage pulse noise by amorphous core. MYB-1230-33 (2) Block terminal with cover Simple wire connection High safety by cover. m Safety standard UL1283, CSA Std. C22. 2 No. 8 VDE0565 Teil. 3, Teil 3A2 VDE0565 will transfer to EN133200 () on and after July 23, 2003. MYB-1206-33 MYB-1210-33 m Specifications Model MYB-1206-33 MYB-1210-33 MYB-1220-33 MYB-1230-33 Item 1 Rated voltage (AC, DC) 250V 2 Rated current (AC, DC) (Note) 6A 10A 20A 30A 3 Test voltage (terminal to case, AC 1 minute) 2500V (25C, 70% RH) 4 Isolation resistance (terminal to case, 500VDC) 100M min. (25C, 70% RH) 125V, 60Hz 0.25mA max. 5 Leakage current 250V, 60Hz 0.5mA max. 6 DC resistance 0.1 max. 0.05 max. 0.02 max. 0.01 max. 7 Temperature rise 30C max. 8 Operating temperature 25 ~ +85C 9 Operating humidity 30% ~ 90% RH (No dewdrop) 10 Storage temperature 30 ~ +85C 11 Storage humidity 10% ~ 95% RH (No dewdrop) 12 Vibration Sweep: 10 ~ 55 ~ 10Hz (for 1 minute), Amplitude: 1.5mm X, Y and Z axes for 2 hours 13 Safety standard Approved by UL1283, CSA C22.2 No. 8 (C-UL) and VDE0565 Teil3, Teil3A2 14 Weight (typ) 210g 260g 450g 510g < (Note) : Value at Ta 50C. Refer to the derating curve shown below at Ta > 50C.= m Circuit m Derating v Request customer specification for further details of specifications, outline, characteristics, etc. Read the instruction manual before usage. v Contact us about delivery before ordering. 159Noise Filter MYB-SERIES m MYB-1206-33 m MYB-1210-33 Models A B C D MXB-1206-33 108 75 90 26 MXB-1210-33 118 85 100 30 m MYB-1220-33 m MYB-1230-33 Case: Metal (Unit: mm) 160