Load (%) NND15 Specifications NEMIC-LAMBDA 1 V 2 A 3 W 4 % 5 - 6 A 7 - 8 % 9 mV mV mV mV A V - - - - - - - - - - - - - - - - CSA950 - - - g mm CURVE 100 =NOTES= *1. 80 *2. 60 *3. 40 *4. *5. 20 *6. 0 -20 0 20 40 50 60 71 Ambient Temperature (C) See Outline Drawings. manual reset. (Line recycle) For each output - OVP circuit will shut down output, Foldback current limit with automatic recovery for each output. Floating output or grounded +V or -V Terminal. 250VAC max. and frequency range 47-63Hz. ( UL, CSA, EN etc. ) are required, input voltage will be For cases where conformance to various safety specs. At 100VAC and maximum output power. OUTPUT DERATING *Read instruction manual carefully, before using the power supply unit. 60 x 113.5 x 150 (*6) Size (WxHxD) 33 1750 Weight 32 Built to meet VCCI-1, FCC Class B, VDE Class B EMI 31 Approved by TUV EN60950 Approved by C-UL Approved by UL UL1950 Safety 30 Less than 20G Shock (In package) 29 less than 2G X, Y, Z 1hour each 10 ~ 55Hz Amplitude (Sweep for 1min.) Vibration 28 at DC 500V 25C and 70%RH for 1min. More than 100M Isolation Resistance 27 Input - Chassis : 2.5kVAC for 1min. 20mA Input - Output : 3.75kVAC for 1min. 20mA Withstand Voltage 26 0.02% / C (*1) Temperature Coefficient (Typ) 25 Convection Cooling Cooling 24 10 ~ 95%RH (No Dewdrop) Storage Humidity 23 -40 ~ +85C Storage Temperature 22 30 ~ 95% (No Dewdrop) Operating Humidity 21 -20 ~ +71C -20C : 60%, 0 ~ 50C : 100%, 60C : 60%, 71C : 40% Operating Temperature 20 Series Operation 19 Parallel Operation 18 17 Remote ON/OFF Control 16 Remote Sensing 15 Remote Programming Crowbar Type 18.1 ~ 21.5 14.5 ~ 17.2 (*5) Over Voltage Protection 14 0.63 ~ 0.78 0.79 ~ 0.98 (*4) Over Current Protection 13 4.5 3.6 Maximum Cross Regulation 12 4.5 3.6 Maximum Load Regulation 11 1.5 1.2 Maximum Line Regulation 10 1mV RMS, 3mV p-p Each Output (*3) Maximum Ripple & Noise 10 Adjustable for Each Output Output Voltage Range 20A at 100VAC, 10A at 200VAC, cold start Inrush Current(Typ) 0.75 0.75 (*1) Input Current (Typ) 200: 170 ~ 230 VAC 230: 195 ~ 265 VAC 100: 85 ~ 115 VAC 115: 98 ~ 132 VAC 47 ~ 440Hz (*2) Input Voltage Range 45 45 (*1) Efficiency (Typ) 18 18 Maximum Output Power 0.6 0.75 Maximum Output Current 15 12 Nominal Output Voltage -1515 -1212 ITEMS NND15 NND15 MODEL IA502-01-01E *:For delivery, contact to our sales office.NND 15 OUTPUT DERATING NEMIC-LAMBDA LOAD (%) -20 60 -10 80 0 ~ +50 100 60 60 71 40 0 0 MOUNTING : A Load (%) (STANDARD MOUNTING) Ambient Temperature (C) 71 60 50 40 20 -20 20 40 60 80 100 OUTPUT DERATING CURVE MOUNTING : A Ta (C)