Load (%) NNS30 Specifications NEMIC-LAMBDA NNS30 NNS30 NNS30 NNS30 NNS30 1 V 5 2 A 3 W 4 % 5 - 6 A 7 - 8 - 9 - mV mV A V - - - N.A. - - - C - C - - - - - - - CSA950 - - - g mm =NOTES= 100 *1. *2. 80 60 *3. *4. 40 *5. 20 *6. 0 -20 0 20 40 50 60 71 Ambient Temperature (C) manual reset. (Line recycle) For each output - OVP circuit will shut down output, See Outline Drawings. each output. Foldback current limit with automatic recovery for Floating output or grounded +V or -V Terminal. 250VAC max. And frequency range 47 ~ 63Hz. ( UL,CSA, EN etc. ) are required, input voltage will be For cases where conformance to various safety specs. At 100VAC and maximum output power. OUTPUT DERATING CURVE *Read instruction manual carefully, before using the power supply unit. 80 x 124 x 178 (*5) Size (WxHxD) 32 2930 Weight 31 Designed to meet VDE0871-Class B,VCCI-Class A, FCC20780-Class B, Conducted Radio Noise 30 Approved by TUV EN60950 Approved by C-UL Approved by UL UL1950 Safety 29 Less than 20G Shock 28 less than 2G X, Y, Z 1hour each 10 ~ 55Hz Amplitude (Sweep for 1min.) Vibration 27 at DC 500V 25C and 70%RH for 1min. More than 100M Isolation Resistance 26 Input - Chassis : 2.5KVAC for 1min. 20mA Input - Output : 3.75KVAC for 1min. 20mA Withstand Voltage 25 0.02% / C (*1) Temperature Coefficient 24 Convection Cooling Cooling 23 10 ~ 95%RH Storage Humidity 22 -40 ~ +85C Storage Temperature 21 30 ~ 95%RH Operating Humidity 20 -20 ~ +71C -20C:60%, 0 ~ 50C:100%, 60C:60%, 71C:40% Operating Temperature 19 Possible Series Operation 18 Possible, current sharing with single connection Via PC terminal Parallel Operation 17 Remote ON/OFF Control 16 Possible, Via +S, -S Terminals Remote Sensing 15 /Volt typ. +S to +LS Terminals Volt/Volt, 1000 Remote Programming 14 Crowbar Type 58.1 ~ 68.6 29.0 ~ 34.3 18.1 ~ 21.5 14.5 ~ 17.2 6.0 ~ 7.2 (*6) Over Voltage Protection 13 1.15 ~ 1.43 2.42 ~ 3.00 3.57 ~ 4.42 4.2 ~ 5.2 6.3 ~ 7.8 (*4) Over Current Protection 12 14.4 7.2 4.5 3.6 1.5 Maximum Load Regulation 11 4.8 2.4 1.5 1.2 0.5 Maximum Line Regulation 10 1mV RMS, 3mV p-p (*3) Maximum Ripple & Noise 10% Output Voltage Range 20A at 100VAC, 10A at 200VAC, COLD START In-rush Current(Typ) 1.35 1.45 1.47 1.41 1.14 (*1) Input Current (Typ) 200: 170 ~ 230 VAC 230: 195 ~ 265 VAC 100: 85 ~ 115 VAC 115: 98 ~ 132 VAC 47 ~ 440Hz (*2) Input Voltage Range 54 50 46 45 35 (*1) Efficiency (Typ) 52.8 55.2 51.0 48.0 30.0 Maximum Output Power 1.1 2.3 3.4 4.0 6.0 Maximum Output Current 48 24 15 12 Nominal Output Voltage -48 -24 -15 -12 -5 ITEMS MODEL IA501-01-01E *:For delivery, contact to our sales office.NNS 30 OUTPUT DERATING NEMIC-LAMBDA LOAD (%) -20 60 -10 80 0 ~ +50 100 60 60 71 40 0 0 MOUNTING : A Load (%) (STANDARD MOUNTING) Ambient Temperature (C) 71 60 50 40 20 -20 20 40 60 80 100 OUTPUT DERATING CURVE MOUNTING : A Ta (C)