DC/DC Module 400W-700W PAF SERIES 2 PAF Features Model naming method F ull brick industry standard size (6112.7116.8mm) PAF 500 F 48 12 / H igh power density (industry-leading level in PAF700- Option F48) Blank: Standard T: Through hole type Broad range of baseplate operating temperatures: -40 to +100C (-20 to +85 for PAF400F280) Nominal output voltage High ecffi iency: 91% max (PAF700F48/PAF450F280/ Nominal input voltage PAF600F280) Function Large output current applicable to low voltage model: F: Full function 100A (PAF400F280-1.8/3.3) Output power Wide variety of functions 400, 450, 500, 600, 700W Remote sensing (+S/-S), ON/OFF control (CNT), Out- Series name put voltage trimming (TRM), Inverter operation monitor- ing (IOG), Parallel control (PC), Auxiliary power supply (AUX), Over voltage protection (OVP), Over current protection (OCP) Internal capacitor: Ceramic capacitor only (high reli- Conformity to RoHS Directive ability) This means that, in conformity with EU Directive 2002/95/ Applications EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. Product Line up PAF-F24 DC24Vin PAF-F48 DC48Vin 500W 600W 500W 600W 700W Output Voltage Output Current Model Output Current Model Output Current Model Output Current Model Output Current Model 3.3V 80A PAF500F48-3.3 5V 80A PAF500F48-5 12V 42A PAF500F24-12 50A PAF600F24-12 42A PAF500F48-12 50A PAF600F48-12 58.5A PAF700F48-12 28V 18A PAF500F24-28 21.5A PAF600F24-28 18A PAF500F48-28 21.5A PAF600F48-28 25A PAF700F48-28 PAF-F280 DC280Vin Output 400W 450W 600W Voltage Output Current Model Output Current Model Output Current Model 1.8V 100A PAF400F280-1.8 3.3V 100A PAF400F280-3.3 5V 80A PAF400F280-5 12V 38A PAF450F280-12 50A PAF600F280-12 24V 19A PAF450F280-24 25A PAF600F280-24 Note) The pin configuration differs depending on 28V 16.5A PAF450F280-28 21.5A PAF600F280-28 the product. Refer to the appearance dia- 48V 9.5A PAF450F280-48 12.5A PAF600F280-48 gram for detail. All specifications are subject to change without notice. B-93PAF 500F24 PAF500F24 Specifications PAF500F24 MODEL PA F5 0 0 F 24 -12 PA F5 0 0 F 24 -2 8 ITEMS/UNITS Voltage Range V DC19 - 36 DC18 - 36 Input Efficiency (typ) (*1) 89 90 Current (typ) (*2) A 24 23.8 Nominal Voltage VDC 12 28 Maximum Current A 42 18 Maximum Power W 504 Voltage Setting Accuracy (*2) 1 Output Maximum Line Regulation (*3) mV 24 56 Maximum Load Regulation (*4) mV 24 56 Temperature Coefficient 0.02%/ Maximum Ripple & Noise (*10) mVp-p 200 280 Voltage Adjustable Range (*10) -40%, +10% Over Current Protection (*5) 105% - 140% Over Voltage Protection (*6) 115% - 135% Remote Sensing (*9) Possible Function Remote ON/OFF Control (*9) Possible (SHORT: ON OPEN: OFF) Parallel Operation (*9) Possible Series Operation (*9) Possible I.O.G. Signal (*9) Possible (Open collector output) Operating Temperature (*7) -40 to +100 (Baseplate) Ambient Temperature min=-40 Storage Temperature -40 to +100 Operating Humidity RH 20 - 95 (No dewdrop) PAF Storage Humidity RH 10 - 95 (No dewdrop) Environment At no operating, 10-55Hz (sweep for 1min.) Vibration Amplitude 0.825mm constant (maximum 49.0m/s) X, Y, Z 1 Hour each Shock 196.1m/s Cooling (*8) Conduction cooled Input-Baseplate : 1.5kVDC, Input-Output : 1.5kVDC for 1min. Withstand Voltage Output-Baseplate : 500VDC for 1min. Isolation Isolation Resistance More than 100M at 25 and 70%RH Output-Baseplate...500VDC Standards Safety Standards Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1 Weight (typ) g 250 Mechanical Size (W x H x D) mm 61 x 12.7 x 116.8 (Refer to outline drawing) (*1) At 24VDC, 80% of maximum output current and baseplate tem- (*6) Inverter shutdown method, manual reset. perature = +25 . (*7) Ratings - Refer to derating curve below. (*2) At 24VDC and maximum output current. - Load(%) is percent of maximum output current. (*3) 19 - 36VDC, constant load. (PAF500F24-12) (*8) Heatsink has to be chosen according to instruction manual. 18 - 36VDC, constant load. (PAF500F24-28) (*9) Refer to instruction manual. (*4) No load - full load, constant input voltage. (*10) External components are needed for operation. (*5) Constant current limiting with automatic recovery. (Refer to basic connection and instruction manual.) Output Derating 120 100 80 60 40 20 Outline DrawingBasic Connection B-99Page -40 -20 0 20 60 80 100 120 B-94 All specifications are subject to change without notice.