TDK- Lambda RDS1 8 0 -2 4 SPECIFICATIONS B030-01-01A MODEL RDS180-24-5 RDS180-24-12 RDS180-24-15 RDS180-24-24 ITEMS 1 Nominal Output Voltage V 5 12 15 24 2 Maximum Output Current A 36 15 12 7.5 3 Maximum Output Power W 180 180 180 180 4 Efficiency (Typ) (*1) % 78 79 80 5 Input Voltage Range - 18 - 32VDC 9.6 6 Input Current (Typ) (*1) A 7 Inrush Current (Typ) (*1) - 30A at Cold Start 8 Output Voltage Range (*8) V 4.0 - 6.0 9.6 - 14.4 12.0 - 18.0 19.2 - 28.8 9 Maximum Ripple (*2) mV 50 80 80 100 10 Maximum Ripple & Noise (*2) mV 100 170 200 290 11 Maximum Line Regulation (*3) mV 40 96 120 192 12 Maximum Load Regulation (*4) mV 50 120 150 240 13 Temperature Coefficient - Less than 0.02 %/ 14 Over Current Protection (*5) A 37.8 - 48.6 15.7 - 20.3 12.6 - 16.2 7.8 - 10.2 15 Over Voltage Protection (*6) V 6.2 - 7.3 15 - 17.4 18.7 - 21.8 30.0 - 34.8 16 Remote ON/OFF control - Possible 17 Parallel Operation - Possible 18 Series Operation - Possible 19 Operating Temperature (*7) - -20 - +60C (-20 - +50C:100%, +60C:70%) 20 Operating Humidity - 20 - 95%RH (No Condensing) 21 Storage Temperature - -25 - +75C 22 Storage Humidity - 20 - 95%RH (No Condensing) 23 Cooling - Convection Cooling 24 Withstand Voltage - Input - Output, Input - FG : 2kVAC (10mA) for 1min., Output - CNT(RC) : 100VAC (100mA) for 1min. Output - FG : 500VDC more than 100M, Output - CNT(RC) : 100VDC more than 10M 25 Isolation Resistance - 2 26 Vibration - 10 - 55Hz : 19.6m/s , X,Y,Z 1hour each. JIS E 3014-2-B 2 27 Shock - 294m/s (time : 63ms) JIS E 3015-2-B 28 Safety - Approved by UL60950-1 & CSA60950-1, Designed to meet EN60950-1 29 Conducted Emission - Designed to meet EN55011/EN55022-A, FCC-ClassA, VCCI-A 30 Radiated Emission - Designed to meet EN55011/EN55022-A, FCC-ClassA, VCCI-A 31 Immunity - Designed to meet IEC61000-4-2(Level 2,3), -4(Level 3), -8(Level 4) 32 Weight (Typ) g 1400 33 Size (W x H x D) mm 80 x 95 x 220 ( Refer to Outline Drawing ) *Read instruction manual carefully, before using the power supply unit. =NOTES= *1. At 24VDC, Ta=25C, nominal output voltage and maximum output power. *2. Measure with JEITA RC-9131A probe, Bandwidth of scope :100MHz. *3. 18 - 32VDC, constant load. *4. No load-Full load, constant input voltage. *5. OCP TYPE : Constant current limit with automatic recovery. *6. OVP circuit will shut the output down, manual reset (Re power on). Ratings *7. - Derating at standard mounting. Refer to output derating curve(B030-01-02 ). - Load (%) is percent of maximum output power or maximum output current, whichever is greater. *8. At 24VDC Input.(Refer to instruction manual.) TDK- Lambda RDS1 8 0 - 2 4 OUTPUT DERATING B030-01-02A *COOLING : CONVECTION COOLING LOAD (%) Ta (C) MOUNTING A MOUNTING B -20 - +40 100 100 50 100 70 60 70 - OUTPUT DERATING CURVE 120 100 80 MOUNTING A 60 MOUNTING B 40 20 0 -20 -10 0 10 20 30 40 50 60 70 80 Ta (C) DON T USE MOUNTING A MOUNTING B MOUNTING C MOUNTING D MOUNTING E (STANDARD MOUNTING) 10mm Foot Space for mounting A must be 10mm or higher when having a load larger than 150W. LOAD (%)