XMS500 emea.tdk-lambda.com/xms500 product.tdk.com/en/power/xms 500W, Configurable, Class I or II AC-DC, power supply Medical Industrial Test Broadcast Comms Renewable Features Benefits BF ready medical isolation (MOPP) Eases design into systems (including BF) Class I / II with level B EMC Eliminates need for additional EMC filters Suitable for BFD applications Defibrillator proof refer to technical support Low airflow requirement Allows quieter system design 5 year warranty Low cost of ownership Input 90-264Vac (100-240Vac nominal) Input Voltage able to withstand input voltages of up Input Frequency 47 - 63Hz to 300Vac for up to 5 seconds Input Harmonics EN61000-3-2 compliant Power Factor 0.95 min at 110Vac input Dual fusing (single fuse optional) <40A at 25C and 264Vac (cold start) Input Fuse Inrush Current Time Delay (not user replaceable) (meets EN61000-3-3). Earth Leakage Current specified at 264Vac (63Hz). see How To Create A Product Description for options Quick Selector (Standard models). Additional variants available - see How To Create A Product Description Output Class I Class II Cover / Chassis / Fan type Volts Current Product Description Order code Product Description Order code Open Frame XMS500-12-5H-N2NBRInA XMS5001M XMS500D-12-5H-N2NBDInA XMS50024 12V 41.6A U chassis XMS500-12-5H-N2SBRInA XMS5003X XMS500D-12-5H-N2SBDInA XMS5004F Top fan XMS500-12-5H-TFSBRInA XMS5005Y XMS500D-12-5H-TFSBDInA XMS5006G Open Frame XMS500-24-5H-N2NBRInA XMS50070 XMS500D-24-5H-N2NBDInA XMS5008H 24V 20.8A U chassis XMS500-24-5H-N2SBRInA XMS50091 XMS500D-24-5H-N2SBDInA XMS500BN Top fan XMS500-24-5H-TFSBRInA XMS500C6 XMS500D-24-5H-TFSBDInA XMS500DP Open Frame XMS500-36-5H-N2NBRInA XMS500FR XMS500D-36-5H-N2NBDInA XMS500G8 36V 13.8A U chassis XMS500-36-5H-N2SBRInA XMS500HS XMS500D-36-5H-N2SBDInA XMS500JT Top fan XMS500-36-5H-TFSBRInA XMS500KB XMS500D-36-5H-TFSBDInA XMS500LV Open Frame XMS500-48-5H-N2NBRInA XMS500MC XMS500D-48-5H-N2NBDInA XMS500NW 48V 10.4A U chassis XMS500-48-5H-N2SBRInA XMS500PX XMS500D-48-5H-N2SBDInA XMS500RY Top fan XMS500-48-5H-TFSBRInA XMS500SG XMS500D-48-5H-TFSBDInA XMS500T0 Standard models include:- 5H standby (5V / 2A), N2 fan supply (12V / 0.3A variable supply voltage) except on Top fan variants , B touch current (<100A), In remote on/off (inhibit) and A AC Fail. Class I standard models include R earth leakage (<150A). Isolation Input to Output Reinforced 2 x MoPP, 5.7kVdc, 4kVac Input to Earth Basic 1 x MoPP, 1.5kVac, 2.3kVdc Output to Earth Basic 1 x MoPP, 1.5kVac, 2.3kVdc (class I only) (class I only) XMS500 Datasheet 260272 - v5.0 1 XMS500How To Create A Product Description Channel 1 Output Voltage a Standby Supply Fan / Fan Supply Chassis Option Touch Current a Output Max Current Name Output V/A Name Option Name Option Name Option 12 41.6A NN do not connect N No fan supply N Open frame B <100A 24 20.8A 5C 5V / 0.5A N2 12V variable S U chassis 36 13.8A 5H 5V / 2A N3 12V fixed 40* 12.5A Top fan (needs S 12M 12V / 1A TF chassis) 48 10.4A Fan Touch Earth Remote AC XMS500 Vout - Stby - Chassis Fuses supply current leakage on/off Good Safety class Earth Leakage Current a Remote On/Off AC Fail feature Fuse options Entry Safety Class Name Option Name Option Name Option Entry Option - Class I D class II (no earth) En Enable N None blank Dual fuses D- Class II R <150A In Inhibit A AC Fail Single fuse in FL Live line a - additional variants available, consult sales office * Confirm availability of required product with sales office Output Specification Output Power 500W Continuous with specified airflow or top fan. Including Line regulation of 0.1% (for 90-264Vac input change), Load regulation of 1% Total Regulation better than 2% (for 0-100% load change) and thermal regulation of 0.02%/C (0-50C) Ripple & Noise 1% pk-pk, using EIAJ test method & 20MHz bandwidth Voltage Setting Accuracy 1% at 50% load Turn on Time 1.0s max at 90 Vac & 100% rated output power Efficiency up to 92% At 230Vac, 100% load minimum at 100% load Hold up 16ms 20ms holdup option available, consult sales office for details. Min Load None Transient Response Deviation <5% of set voltage for 25% to 100% load change Recovery time <2ms for recovery to 2% of set voltage Short circuit protection Yes Hiccup mode, auto recovery after removal of short circuit Over Temperature protection Yes Latching, need to cycle ac to restart unit. Over Voltage Protection Yes Latching, need to cycle ac to restart unit. Signals Remote on/off Enable (-En option) - Connect to Standby + to enable channel 1. Open circuit or 0V to inhibit. J2, pin 5 Inhibit (-In option) - Connect to Standby + to inhibit channel 1. Open circuit or 0V to enable. Maximum current required = 2mA for 5V standby supply, 7mA for 12V standby supply AC Fail Provides ac fail functionality. Logic high = ac fail, 0V = ac good. Additional Outputs Fan supply options N None N2 12V / 0.3A (with 12V output, 0.15A with all other outputs). Output voltage varies with heat sink temperature. See application note for details. N3 12V / 0.3A (with 12V output, 0.15A with all other outputs). Constant voltage. TF Top fan (fan supply not for customer use as used by factory fitted top fan) Standby Supply options NN None 5C 5V / 0.5A 5H 5V / 2A 12M 12V / 1A XMS500 Datasheet 260272 - v5.0 XMS500 2