Universal Input (85 - 265VAC) Power Factor Corrected Floating Adjustable Fourth Output Low Profile <1U High Key Market Segments & Applications Factory Automation Test & Measurement ZWQ Series Light Industrial Equipment 80W to 170W Quad Output Power Supplies ZWQ Features and Benefits Features Benefits Low Profile Fits in 1U Enclosures Adjustable Main and Fourth Output System Optimization Power Factor Corrected Supports Global Use Floating Fourth Output Can be used as Positive or Negative Output Specifications Models ZWQ80 ZWQ80 ZWQ80 ZWQ80 ZWQ130 ZWQ130 ZWQ130 ZWQ130 Items -5222 -5223 -5224 -5225 -5222 -5223 -5224 -5225 Input Voltage - 85-265VAC (47-63Hz), 120-370VDC Input Current (1) A 1.6 / 0.8 2.6 / 1.3 Inrush Current (1) A 14/28 Power Factor - Meets EN61000-3-2 Temperature Coefficient - <0.02%/C Max Output Power (convection) W 80 130 Max Output Power (forced air) W 104 88.7 104 104 170 149.6 170 170 Overpower Protection (2) W >109 >93 >109 >109 >173 >152 >173 >173 Minimum Load A V1: 0.9A Conv, 1.4A Forced Air V1: 1.5A Conv, 2.1A Forced Air Output Voltage Accuracy % 5% for outputs V2 and V3 Efficiency (Typ) % 72 Hold Up Time (1) ms 20 Leakage Current - 0.75mA max, 0.2mA (Typ) at 100VAC / 0.44mA(Typ) at 230VAC Remote On / Off - See installation manual (Not available with /A cover option) Oper Temp (convection cooled) - -10C to 60C, derate linearly to 50% load from 40C to 60C. (3) Oper Temp (forced air cooled) - -10C to 70C, derate linearly to 50% load from 50C to 70C. (>30cfm airflow) (3) Storage Temperature - -30C to +85C Humidity (non condensing) - Operating: 30 - 90% RH Non-operating 10-95% RH Withstand Voltage I/P~Gnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Gnd 500VAC (100mA) for 1 min. Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC 2 Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s constant X, Y, Z 1 hour 2 Shock - < 196.1 m/s Safety Agency Approvals - IEC/UL/CSA/EN62368-1, 60950-1, CE Mark Conducted & Radiated EMI - EN55011, EN55022-B, FCC Class B, VCCI-B Immunity - EN61000-4-2,-3,-4,-5,-6,-8,-11 Weight (Typ) g 550 730 Size (W x H x D) mm 93.5 x 35 x 210 106 x 35 x 225 Warranty yr 1 Notes: (1) 100/200VAC (3) /A version - additional derating - See installation manual (2) Avoid prolonged operation in overload 1 ZWQ SeriesModel Selector Voltage Peak or Max Max Ripple MODEL Adjust Convect. Forced Air Load Reg Line Reg Noise OVP Output Voltage (V) Range (V) (A) (A)(4) (mV) (mV) (mV) (V)(5) ZWQ80-5222 V1 5 5.0-5.25 8.0 10.0 100 20 120 5.7-7.0 V2 +12/15* +12/+15 2.0 2.5 300 48 150 16.5-22.5 V3 -12/15* -12/-15 2.0 2.5 300 48 150 16.5-22.5 V4 12 11.4-12.6 3.0 4.0 300 48 150 13.8-16.2 ZWQ80-5223 V1 5 5.0-5.25 8.0 10.0 100 20 120 5.7-7.0 V2 +12/15* +12/+15 2.0 2.5 300 48 150 16.5-22.5 V3 -12/15* -12/-15 2.0 2.5 300 48 150 16.5-22.5 V4 3.3 2.0-3.63 7.0 9.0 100 20 120 3.79-4.95 ZWQ80-5224 V1 5 5.0-5.25 8.0 10.0 100 20 120 5.7-7.0 V2 +12/15* +12/+15 2.0 2.5 300 48 150 16.5-22.5 V3 -12/15* -12/-15 2.0 2.5 300 48 150 16.5-22.5 V4 24 22.8-25.2 1.5 2.0 400 96 200 27.6-32.4 ZWQ80-5225 V1 5 5.0-5.25 8.0 10.0 100 20 120 5.7-7.0 V2 +12/15* +12/+15 2.0 2.5 300 48 150 16.5-22.5 V3 -12/15* -12/-15 2.0 2.5 300 48 150 16.5-22.5 V4 5 2.0-5.25 7.0 9.0 100 20 120 5.7-7.0 ZWQ130-5222 V1 5 5.0-5.25 15.0 19.0 100 20 120 5.7-7.0 V2 +12/15* +12/+15 4.0 5.0 300 48 150 16.5-22.5 V3 -12/15* -12/-15 4.0 5.0 300 48 150 16.5-22.5 V4 12 11.4-12.6 4.0 5.0 300 48 150 11.4-12.6 ZWQ130-5223 V1 5 5.0-5.25 15.0 19.0 100 20 120 5.7-7.0 V2 +12/15* +12/+15 4.0 5.0 300 48 150 16.5-22.5 V3 -12/15* -12/-15 4.0 5.0 300 48 150 16.5-22.5 V4 3.3 2.0-3.63 10.0 12.0 100 20 120 3.79-4.95 ZWQ130-5224 V1 5 5.0-5.25 15.0 19.0 100 20 120 5.7-7.0 V2 +12/15* +12/+15 4.0 5.0 300 48 150 16.5-22.5 V3 -12/15* -12/-15 4.0 5.0 300 48 150 16.5-22.5 V4 24 22.8-25.2 2.0 2.5 400 96 200 27.6-32.4 ZWQ130-5225 V1 5 5.0-5.25 15.0 19.0 100 20 120 5.7-7.0 V2 +12/15* +12/+15 4.0 5.0 300 48 150 16.5-22.5 V3 -12/15* -12/-15 4.0 5.0 300 48 150 16.5-22.5 V4 5 2.0-5.25 10.0 12.0 100 20 120 5.7-7.0 * User selectable via connector on PCB. Outputs are floating from V1 & V4 Notes: (4) Peak current draw must not exceed 10s duration, duty cycle 35%. (5) OVP on any output will shut down all outputs. Recycle AC input to reset. Options Suffix Description 2 blank No cover or L Bracket /L L Bracket /A Cover and L Bracket 2 ZWQ Series