100F0111 Issue 9 Specification Control Drawing 27th May 2009 Page 1 of 2 Page 2 is for internal use only WIRE, HALOGEN FREE, THIN WALL INSULATED, 250 VOLT AC IN ACCORDANCE WITH NF F 63-808, TEMPERATURE CLASSIFICATION 105C (Suitable for use at an operating voltage of 750/1300 VOLTS AC) Conductor - Insulation - Tin Plated Copper Halogen Free Polymer C8 C9 C14 C11 C16 C17 C18 C21 C20 Part NF F 63-808 Nominal Nominal Conductor FINISHED WIRE Description Designation Cross Conductor Diameter Minimum Maximum Diameter Nominal Maximum Base Sectional Stranding (mm) Insulation Resistance (mm) Weight Weight Colour Area No./Diam. Thickness 20C Lower Upper (kg/km) (kg/km) (mm) (mm) (mm) (ohms/km) Spec Target Spec Min. Max. Limit Limit 100F0111-22 N/A 0.38 19/0.16 0.74 0.76 0.20 50.5 1.26 1.29 1.34 4.46 4.63 * 100F0111-20 E 250 S 0.60-NF F 63-808 0.60 19/0.20 0.96 0.98 0.20 30.0 1.47 1.51 1.55 6.86 7.10 yellow 100F0111-18 E 250 S 0.93-NF F 63-808 0.93 19/0.25 1.21 1.24 0.20 20.0 1.70 1.75 1.80 10.5 10.8 white 100F0111-16 E 250 S 1.34-NF F 63-808 1.34 19/0.30 1.45 1.48 0.20 13.7 1.99 2.04 2.10 13.9 14.9 green 100F0111-14 E 250 S 1.82-NF F 63-808 1.82 37/0.25 1.68 1.72 0.20 9.80 2.30 2.36 2.45 19.8 20.7 yellow 100F0111-12 E 250 S 2.61-NF F 63-808 2.61 37/0.30 2.03 2.08 0.25 7.00 2.62 2.70 2.79 26.4 27.6 white 100F0111-10 E 250 S 4.32-NF F 63-808 4.32 61/0.30 2.53 2.90 0.25 4.46 3.29 3.38 3.51 43.8 47.0 green This size is not covered by NF F 63-808 but except as stated, is tested to the requirements of NF F 63-808 Mai 1992. COLOUR Insulation colour determined by conductor cross sectional area, as defined above. CODE: * = Insulation colour determined by customer order. PERFORMANCE The complete requirements for procuring the wire described herein shall consist REQUIREMENTS: of this document and NF F 63-808 Mai 1992 except where indicated. MARKING: Marking shall be vertically (longitudinally NF F Spec), REQUIREMENT: spaced at 100 mm minimum to 150mm maximum, coloured black Legend: E - NF F 63-808 - TE Raychem - YY Where: = the conductor cross sectional area (see above) andY = the Year Code Designator in accordance with the table below. e.g. E 0.93 - NF F 63-808 - TE Raychem - 09 reflects 100F0111-18 manufactured in 2009. N.B. When used as a component, the mark is defined by the cable SCD. 100F0111-22 only is marked as follows: E 0.38 - TE Raychem - YY whereY = the Year Code Designator in accordance with the table above. APPROVAL: Electronic sign off - no signatures will appear. Raychem , TE and Tyco Electronics are registered trademarks of Tyco Electronics Corporation. 2009 Tyco Electronics Corporation. All International Rights Reserved.X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Multi-Conductor Cables category: Click to view products by TE Connectivity manufacturer: Other Similar products are found below : 8916-GRY-100 8917-BLK-100 8918-GRN/YEL-100 8920-BRN-1000 8920-RED-1000 89907-LT-DEC/GRY-500 CR3909-000 CR3927- 000 01342.35T.01 01364.35T.01 CS2885-000 CS8782-000 CS9912-000 6200UE-NAT-U1000 CTC-0062-20-9/5-9 CTC-0062-22-9/5-9 6304FE-877-U500 6309UE-877-1000 6320UE-NAT-U1000 644833-000 6502FE 8771000 6504UE-877-U1000 CW9530-000 CX6543-000 CXA-0066-20-4-9CS2973 CXA-0078-16-1-9CS2405 CXA-0078-22-4-9CS2405 CXA-0078-24-4-9CS2405 CXA-0140-16-6/9-9CS2405 CY0660-000 706/2R-BLACK-EACH 720451-000 730859-000 MCC-USB-4-250 752687-000 768146-000 773159-000 7934A-BLK-1000 8125-CHR-100 8164-CHR-1000 820457-000 8205-CHR-1000 8240-BLK-U1000 82723-NAT-1000 82907-NAT-500 83003-YEL-500 83005-WHT-500 83006-DK-GRN-100 83008-WHT-1000 83009-BLK-100