SPECIFICATION CONTROL DRAWING 10613 3-5-15 77 OHM, AWG 24, 19 STRANDS OF AWG 36, Date: OPTIMIZED DOUBLE SHIELDS, DATA BUS CABLE, MIL-STD-1553 CHEMINAX S Revision: THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS DIMENSIONS ARE NOMINAL VALUES IN INCHES, UNLESS OTHERWISE CHARACTERISTIC IMPEDANCE 77 5 ohms, Method C at 1 MHz DESIGNATED. MUTUAL CAPACITANCE 30.0 pF/ft. (98.4 pF/m) (maximum) ATTENUATION 1.4 dB/100 ft. (4.59 dB/100 m) (maximum) at 1 MHz CONDUCTORS SURFACE TRANSFER IMPEDANCE 10 milliohms/meter (maximum) AWG 24, (Per SAE AS85485) at 30 MHz 19 Strands of AWG 36, .0250 Silver-Coated High- ADDITIONAL REQUIREMENTS (.635 mm) Strength Copper Alloy COMPONENT WIRE PRIOR TO CABLING (Test procedures per SAE AS22759) DIELECTRICS .048 .002 Radiation-Crosslinked, CONDUCTOR RESISTANCE 26.5 ohms/1000 ft. (86.9 ohms/km) (nominal) (1.22 .05 mm) Modified ETFE CROSSLINKING PROOF TEST 300 3C for 1 hour, Colors - Light Blue/White .625 inch (15.9 mm) mandrel, .032 FILLERS .375 lb (170 g), 2.5 kV dielectric test (.813 mm) Radiation-Crosslinked, INSULATION (DIELECTRIC) Modified ETFE ELONGATION 50% (minimum) 2 2 TENSILE STRENGTH 5000 lbf/in (34.5 N/mm ) (minimum) INSULATION FLAWS SPARK TEST 3.0 kV (rms) IMPULSE TEST 8.0 kV (peak) INSULATION RESISTANCE 5000 megohms for 1000 ft. (1524 megohms-km) (minimum) 1st SHIELD LOW TEMPERATURE-COLD BEND -65 3C for 4 hours, .113 AWG 38, .750 inch (19.1 mm) mandrel, (2.87 mm) Tin-Coated Copper, 1.00 lb (454 g), 2.5 kV dielectric test Optimized SHRINKAGE 200 3C for 1 hour, .125 inch (3.18 mm) (maximum) in 12 inches (305 mm) 2nd SHIELD FINISHED CABLE AWG 38, .130 (Test procedures per NEMA WC 27500, unless otherwise specified) Tin-Coated Copper, (3.30 mm) BLOCKING 200C for 6 hours Optimized CABLE LA Y LENGTH .75 inch (19.1 mm) (minimum), 1.25 inches (31.8 mm) (maximum) CROSSLINKED VERIFICATION 300 5C for 6 hours, 6.00 inch (152 mm) mandrel FLAMMABILITY 3 seconds (maximum) (Method B of Spec 1200) 3 inches (76.2 mm) (maximum) .146 (3.71 mm) no flaming of facial tissue JACKET (nominal) Radiation-Crosslinked, JACKET .154 (3.91 mm) Modified ETFE ELONGATION 50% (minimum) (maximum) 2 2 TENSILE STRENGTH 5000 lbf/in (34.5 N/mm ) (minimum) JACKET FLAWS SPARK TEST 1.0 kV (rms) IMPULSE TEST 6.0 kV (peak) JACKET THICKNESS .008 inch (.203 mm) (nominal) LOW TEMPERATURE-COLD BEND -55 5C for 4 hours, 6.00 inch (152 mm) mandrel VOLTAGE WITHSTAND 1500 volts (rms) (DIELECTRIC) WEIGHT 26.2 lbs/1000 ft. (39.0 kg/km) (maximum) Designate outer jacket color with a dash number in accordance with MIL-STD-681. Unless otherwise specified, outer jacket color will be CABLE IDENTIFICATION: Outer jacket shall be marked in contrasting color at 12 white (designated by a-9 appended to the part number and inch (305 mm) (nominal) intervals between marks as follows: 10613 RAYCHE conductor AWG size, e.g. 10613-24-9). Other codes and suffixes may be added to the part number, as ENGINEERING REFERENCE necessary, to capture any additional requirements imposed by the TEMPERATURE RATING 150C (maximum) purchase order. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. Page 1 of 2 Cheminax, Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Page 2 is for internal use only. Raychem Wire & Cable THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. 501 Oakside Avenue REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Redwood City, California 94063-3800 2009-2015 Tyco Electronics Corporation. All rights reserved. Phone: 1-800-227-8816 Fax: 1-650-361-6297