General Purpose
Panel/Plug-in Relays
SCHRACK
Multimode Relay MT
n
2/3 pole 10A, 2 form C (CO) or 3 form C (CO) contacts
n
DC and AC coils
n
Mechanical indicator as standard
n
Electrical indicator
n
New test system with front operated finger protected
push-to-test button and integral locking test tab
n
White write on panel
Typical applications
Mechanical engineering, plant control.
Z
Approvals Contact Data (continued)
VDE Cert. No. 40009096, UL E214025 Mechanical endurance
6
Technical data of approved types on request. DC coil 20x10 operations
6
AC coil 20x10 operations
Contact Data
Contact arrangement 2 form C (CO) or 3 form C (CO) Coil Data
Rated voltage 240VAC Coil voltage range 6 to 220VDC
Max. switching voltage 400VAC 6 to 230VAC
Rated current 10A 10A Operative range, IEC 61810 2
Limiting making current, max. 20ms 20A 20A Coil insulation system according UL class 130 (B)
Limiting breaking current 10A 10A
Switching power 2500VA 2500VA Coil versions, DC coil
Contact material AgNi90/10 AgNi90/10 Coil code Rated Operate Release Coil Rated coil
3)
- gold plated STD PD voltage voltage voltage resistance power
1)2)
Contact style single single VDC VDC VDC 10% W
contact contact 006 0A6 6 4.5 0.6 32 1.1
Min. recommended contact load 12V 20mV 012 0B2 12 9.0 1.2 110 1.3
at 10mA at 1mA 024 0C4 24 18.0 2.4 475 1.2
Initial voltage drop 30mV at 100mA/6VAC/1kHz 048 0E8 48 36.0 4.8 2000 1.2
-1
Frequency of operation, with/without load 1200/6000h 060 0G0 60 45.0 6.0 2850 1.3
1)
Operate time max., DC coil 15ms 110 1B0 110 82.5 11.5 10000 1.2
2)
Release time max., DC coil 10ms 220 2C0 220 165.0 22.0 40000 1.2
Bounce time max., DC coil, form A/form B 4/10ms 1) Coil resistance 12%, 2) Coil resistance 15%.
3) Protection diode PD; standard polarity: 2-pole relays: +2 / -7, 3-pole relays: +2 / -10.
All figures are given for coil without pre-energization, at ambient temperature +23C.
Contact ratings
Type Contact Load Cycles
Coil versions, AC coil, 50/60Hz
IEC 61810
3 Coil Rated Operate Release Coil Rated coil
MT22 DC coil C (CO) 10A, 250VAC, cos =1, 35C 100x10
3 code voltage voltage voltage resistance power
MT22 AC coil C (CO) 10A, 250VAC, cos =1, 35C 20x10
3 50/60Hz 50/60Hz 50/60Hz
MT32 DC coil C (CO) 10A, 250VAC, cos =1, 35C 100x10
1)
3 VAC VAC VAC 10% VA
MT32 AC coil C (CO) 10A, 250VAC, cos =1, 35C 20x10
006 6 4.8/5.1 1.8 5.3 2.29/1.98
UL 508
012 12 9.6/10.2 3.6 24 2.19/1.86
MT3 A (NO)/B (NC) B300, 40C 6.000
3 024 24 19.2/20.4 7.2 86 2.26/1.95
MT2 C (CO) 10A, 250VAC, resistive, 40 30x10
048 48 38.4/40.8 14.4 345 2.28/1.97
MT2 A (NO)/B (NC) B300 40C 6.000
3 060 60 48.0/51.0 18.0 544 2.27/1.96
MT3 C (CO) 10A, 250VAC, resistive, 40C 100x10
115 115 92.0/97.8 34.5 2000 2.37/2.00
1)
230 230 184.0/195.5 69.0 8300 2.32/1.96
1) Coil resistance 12%.
All figures are given for coil without pre-energization, at ambient temperature +23C.
1
10-2014, Rev. 1014 Catalog and product specification according Catalog and product data is subject to the Catalog product data, Definitions section,
www.te.com to IEC 61810-1 and to be used only together terms of the disclaimer and all chapters of application notes and all specifications are
2014 Tyco Electronics Corporation, with the Definitions section. the Definitions section, available at subject to change.
a TE Connectivity Ltd. company. General Purpose
Panel/Plug-in Relays
SCHRACK
Multimode Relay MT (Continued)
Insulation Data Other Data
Initial dielectric strength Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
between open contacts 1500Vrms refer to the Product Compliance Support Center at
between contact and coil 2500Vrms www.te.com/customersupport/rohssupportcenter
between adjacent contacts 2500Vrms Ambient temperature
Clearance/creepage DC coil -40 to +60C
between contact and coil 2.8/4mm AC coil -40 to +50C
between adjacent contacts 2.8/4mm Category of environmental protection
Material group of insulation parts IIIa IEC 61810 RTI - dust protected
Vibration resistance (functional),
form A (NO)/form B (NC) 5/2g
Shock resistance (functional),
form A (NO)/form B (NC) 50/10g
Terminal type plug-in
Cover retention, pull/push force 100/100N
Weight 80g
Packaging unit 25 pcs.
Accessories
For details see datasheet Accessories Multimode Relay MT
Note: indicated contact ratings and electrical endurance data for direct
wiring of relays (according IEC 61810-1); for relays mounted on sockets
deratings may apply.
Terminal assignment Dimensions
Bottom view on pins
2
10-2014, Rev. 1014 Catalog and product specification according Catalog and product data is subject to the Catalog product data, Definitions section,
www.te.com to IEC 61810-1 and to be used only together terms of the disclaimer and all chapters of application notes and all specifications are
2014 Tyco Electronics Corporation, with the Definitions section. the Definitions section, available at subject to change.
a TE Connectivity Ltd. company.