General Purpose High Power PCB Relays PPottotter & Brumfielder & Brumfield T92 Series Two-pole Power Relay n 30/40/50A switching capability n Designed to control compressor loads to 3.5 tons, 110LRA / 25.3FLA n Meets requirements of UL 508 and UL 873 spacings - 8mm through air, 9.5mm over surface n Meets requirements of VDE 8mm spacing, 4kV dielectric coil-to- contact n Meets requirements of UL Class F construction n UL approved for 600VAC switching (1.5HP) n Screw terminal version (consult factory for availability, ratings) n Anti-explosive version available (Meets EN 60079-15) n WG version available (Meets EN 60335-1) Typical applications HVAC, residential / commercial appliances, industrial controls, charging 1) Approvals Contact ratings (T92 Type) (continued) UL E22575 CSA LR48471 VDE 40019600 TUV R 50083843 0008 Type Load Cycles TUV 15090924 002 TUV 15090883 001 AgSnOInO 3 Technical data of approved types on request. NO 40A, 240VAC, resistive 85C 50x10 3 NO 30A, 277VAC, resistive (DC coil only) 250x10 3 Contact Data NO 30A, 277VAC, resistive (AC coil only) 100x10 3 Type T92 T92H NO 20A, 506VAC, resistive 100x10 3 Contact arrangement 2 form A (NO) 2 form A (NO) NO 1.5HP, 120VAC, 2 pole making/breaking (Fig.1) 100x10 3 2 form C (CO) NO 3HP, 240VAC, 3 phase (DC coil only) 100x10 3 Rated voltage 277VAC NO 3HP, 480VAC, 3 phase (DC coil only) 100x10 3 Max. switching voltage 600VAC NO 2HP, 600VAC, 3 phase (DC coil only) 100x10 Rated current 30A/40A NO 3A NC 50A NO Special Ag Alloy X (Cd Free), wash tight 3 Overload current* 60A NO 4.5A NC 75A NO NO 30A, 250VAC, resistive 100x10 3 Contact material Ag Alloy NO 30A, 400VAC, resistive 100x10 3 Min. recommended contact load 500mA (NO), 12VAC or 5VDC NO 20A, 480VAC, resistive 100x10 100mA (NC), 12VAC or 5VDC VDE Frequency of operation, with load 360 cycles per hour AgCdO, flange mount relays 3 Operate/release time max., NO 20A, 400VAC 100x10 3 including bounce 25/25ms NC 3A, 400VAC 30x10 3 Initial contact resistance < 100 m at 6VDC 1A CO 20A NO / 3A NC, 400VAC 30x10 *Note: Minimum electrical endurance 50 cycles AgCdO, PC mount relays 3 NO 30A, 400VAC 100x10 3 NC 3A, 400VAC 30x10 1) 3 Contact ratings (T92H Type) CO 30A NO / 3A NC, 400VAC 30x10 UL508 Anti-explosion, sealed type 3 3 NO 50A, 277VAC, resistive, 85C 6x10 NO 30A 250VAC, 25C 100x10 Note: Coil voltage 12-48VDC covered in UL approval Anti-explosion, break device 3 NO 15A 480VAC 100x10 ARI 780-86 Endurance Test (section 6.6): 1) Contact ratings (T92 Type) HVAC Definite Purpose Contactor Standard Type Load Cycles Normally Open Contacts UL508 Single Phase/Two Pole (Both poles together switching a single load) AgCdO 110 LRA, 25.3 FLA, 200K operations (DC Coil) 3 NO 40A, 277VAC, resistive 6x10 L1 L2 3 NO 30A, 277VAC, resistive (DC coil only) 25010 3 NO 30A, 277VAC, resistive (AC coil only) 10010 Figure 1 T1T2 3 NO 10A, 600VAC, resistive 250x10 3 NO 1HP, 120VAC 100x10 Single Phase Per Pole (Single load per pole) 3 NO 3HP, 240VAC 1x10 110 LRA, 18 FLA, 200K operations (DC Coil). 3 NO 1.5HP, 480 or 600VAC 100x10 60 LRA, 14 FLA, 200K operations (AC Coil). 3 NO 110LRA/25.3FLA, 240VAC 100x10 L1 L2 3 NO 7.3A, 240VAC, pilot duty 100x10 3 T1 T2 NO 20A, 28VDC, resistive 100x10 Figure 2 3 NO TV10, 120VAC 25x10 3 NC 3A, 277VAC 100x10 3 1) Contact ratings at 25C (unless otherwise noted) with relay properly vented. NC 2A, 480VAC, general purpose 100x10 3 FLA, LRA ratings are compatible with 3.5 ton compressor applications. NC 1A, 600VAC 100x10 Mechanical endurance 6 T92 10x10 ops. 6 T92H 1x10 ops 1 04-2021, Rev. 0421 Catalog and product specification according Catalog and product data is subject to the Catalog product data, Definitions section, www.te.com to IEC 61810-1 and to be used only together terms of the disclaimer and all chapters of application notes and all specifications are 2012 Tyco Electronics Corporation, with the Definitions section. the Definitions section, available at subject to change. a TE Connectivity Ltd. company. AC Coil 30 A AC Coil 0 A DC Coil 30 Amp Contact Load DC Coil 0 Amp Contact Load General Purpose High Power PCB Relays PPottotter & Brumfielder & Brumfield T92 Series Two-pole Power Relay (Continued) Coil Data Coil Data (continued) Coil voltage range 5 to 110VDC 12 to 240VAC 120 Max. coil power 1.7W 4.0VA Max. coil temperature 155C 100 Coil insulation system according UL Class F 80 Coil versions, DC coil (D type) 60 Coil Rated Operate Release Coil Rated coil 2) 3) 40 code voltage voltage voltage resistance power VDC VDC VDC 10% W 20 5 5 3.75 0.6 14.9 0 6 6 4.5 0.6 22 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 9 9 6.75 0.9 48 Applied Coil Voltage (% of Rated Nominal) 12 12 9 1.2 86 18 18 13.5 1.8 197 1.7W/ Note: This chart only apply for T92 standard type. For coil data of T92 Anti- 22 22 16.5 2.2 294 Min. 0.41W explosion sealed type and T92H type, please contact TE engineering. 24 24 18 2.4 350 hold 36 36 27 3.6 767 48 48 36 4.8 1390 110 110 82.5 11 7255 Insulation Data 120 120 90 12 8514 Initial dielectric strength 2) For T92H type, after the energization time of 100ms with rated voltage, the coil between open contacts 1500V rms requires a reduction of the coil voltage to 50% of rated voltage. between contact and coil 4000V rms 3) For Anti-explosion sealed type, the operate voltage is 80% of the rated coil between adjacent contact 2000V rms voltage. Initial surge withstand voltage between contact and coil 8kV Coil versions, AC coil (A type) Initial insulation resistance ( 500VDC) 9 Coil Rated Frequency Operate Release Coil Rated coil between insulated elements 1x10 code voltage voltage voltage resistance power Clearance/creepage VAC Hz VAC, 60Hz VAC, 60Hz 10% VA between contact and coil 8mm clearance/9.5mm cr eepage 12 12 60 9.6 1.2 9.1 4 24 24 60 19.2 2.4 36.6 4 110 110 60 88 11 793 4 Other Data 120 110/120 50/60 96 12 950 4 Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content 208 208 60 166.4 20.8 2841 4 refer to the Product Compliance Support Center at 240 220/240 50/60 192 24 3800 4 www.te.com/customersupport/rohssupportcenter 277 250/277 50/60 221.6 27.7 5485 4 Ambient temperature Coil versions, AC coil (F type) DC coil -55C to 85C Coil Rated Frequency Operate Release Coil Rated coil AC coil -55C to 65C code voltage voltage voltage resistance power Category of environmental protection VAC Hz VAC, 60Hz VAC, 60Hz 10% VA IEC 61810 RTI - dust protected, 12 12 50 9.6 1.2 11.2 3.5 R TII - flux proof, RTIII - wash tight 24 24 50 19.2 2.4 44.4 3.5 Vibration resistance (functional) 1.65mm max amplitude, 10-55 Hz 48 48 50 38.4 4.8 179.2 3.5 Shock resistance (functional) 10G for 11msec 240 240 50 192 24 4355 3.5 Shock resistance (destructive) 100G All figures are given for coil without preenergization, at ambient temperature +23C. Terminal type PCB / Quick Connect / Screw For A type, 110V/120V, 50/60Hz. Signify 50Hz Operation at Nominal 110V, 60 Hz Operation at Nominal 120V. 2 04-2021, Rev. 0421 Catalog and product specification according Catalog and product data is subject to the Catalog product data, Definitions section, www.te.com to IEC 61810-1 and to be used only together terms of the disclaimer and all chapters of application notes and all specifications are 2012 Tyco Electronics Corporation, with the Definitions section. the Definitions section, available at subject to change. a TE Connectivity Ltd. company.