RF Signal Relays AXICOM HF3 Relay n Y-Design n Frequency range DC to 3GHz n Impedance 50 or 75 n Small dimensions (14.6x7.2x10mm) n 1 form C contact (1 changeover contact) n Immersion cleanable n Low power consumption (140mW) Typical applications Cable modems and linecards/ CATV, Tabs, measurement and test equipment ATE, satellite / audio / video tuners, wireless base stations and antennas, switching boards Contact Data Coil Data (continued) Contact arrangement 1 form C, 1 CO Max. switching voltage 220VDC, 250VAC Coil versions, bistable Rated current 2A Coil Rated Set Limiting Reset Coil Rated coil Limiting continuous current, 23C 2A code voltage voltage voltage voltage resistance power Switching power 60W, 62.5VA, VDC VDC VDC VDC 10% mW 50W (2.5GHz) 50 version, bistable, 1 coil Max. continuos RF-power, 23C 50W (2.5GHz) 71 3 2.25 9.20 -2.25 128 70 Contact material Ag, Au covered 72 4.5 3.38 13.85 -3.38 289 70 Minimum switching voltage 100V 73 5 3.75 15.30 -3.75 357 70 Initial contact resistance <100m at 10mA, 30mV 74 6 4.50 18.50 -4.50 514 70 Operate time typ. 3ms, max. 5ms 75 9 6.75 27.70 -6.75 1157 70 Release time 76 12 9.00 37.00 -9.00 2057 70 without diode in parallel typ. 2ms, max. 5ms 77 24 18.00 74.00 -18.00 8228 70 with diode in parallel typ. 4ms, max. 6ms 50 version, bistable, 2 coils Bounce time typ. 1ms, max. 3ms 91 3 2.25 6.50 2.25 64 140 Duration of set/reset pulse min. 20ms 92 4.5 3.38 9.80 3.38 145 140 7 Mechanical endurance 10 operations 93 5 3.75 10.90 3.75 178 140 94 6 4.50 13.00 4.50 257 140 95 9 6.75 19.60 6.75 574 140 Coil Data 96 12 9.00 26.10 9.00 1028 140 Coil voltage range 3 to 24VDC 97 24 18.00 52.30 18.00 4114 140 All figures are given for coil without pre-energization, at ambient temperature +23C. Coil versions, monostable Coil Rated Operate Limiting Release Coil Rated coil Coil Data (continued) code voltage voltage voltage voltage resistance power VDC VDC VDC VDC 10% mW Coil versions, bistable 50 version, monostable, 1 coil Coil Rated Set Limiting Reset Coil Rated coil 51 3 2.25 6.50 0.30 64 140 code voltage voltage voltage voltage resistance power 52 4.5 3.38 9.80 0.45 145 140 VDC VDC VDC VDC 10% mW 53 5 3.75 10.90 0.50 178 140 75 version, bistable, 1 coil 54 6 4.50 13.00 0.60 257 140 21 3 2.25 9.20 -2.25 128 70 55 9 6.75 19.60 0.90 574 140 22 4.5 3.38 13.85 -3.38 289 70 56 12 9.00 26.10 1.20 1028 140 23 5 3.75 15.30 -3.75 357 70 57 24 18.00 52.30 2.40 4114 140 24 6 4.50 18.50 -4.50 514 70 75 version, monostable, 1 coil 25 9 6.75 27.70 -6.75 1157 70 01 3 2.25 6.50 0.30 64 140 26 12 9.00 37.00 -9.00 2057 70 02 4.5 3.38 9.80 0.45 145 140 27 24 18.00 74.00 -18.00 8228 70 03 5 3.75 10.90 0.50 178 140 75 version, bistable, 2 coils 04 6 4.50 13.00 0.60 257 140 41 3 2.25 6.50 2.25 64 140 05 9 6.75 19.60 0.90 574 140 42 4.5 3.38 9.80 3.38 145 140 06 12 9.00 26.10 1.20 1028 140 43 5 3.75 10.90 3.75 178 140 07 24 18.00 52.30 2.40 4114 140 44 6 4.50 13.00 4.50 257 140 All figures are given for coil without pre-energization, at ambient temperature +23C. 45 9 6.75 19.60 6.75 574 140 46 12 9.00 26.10 9.00 1028 140 47 24 18.00 52.30 18.00 4114 140 All figures are given for coil without pre-energization, at ambient temperature +23C. 1 12-2013, Rev. 1213 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec- www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2013 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company AXICOM Telecom-, Signal and RF Relays 108-98000 Rev. F HF3 Relay Terminal assignment Relay top view Non-latching type, Latching type, 1 coil Latching type, 2 coils not energized condition rest condition reset condition AXICOM Telecom-, Signal and RF Relays 108-98000 Rev. F HF3 Relay Terminal assignment Relay top view Non-latching type, Latching type, 1 coil Latching type, 2 coils not energized condition rest condition reset condition Contacts in reset position. Contact po- sition might change during transporta- tion and must be reset before use. RF Signal Relays AXICOM HF3 Relay (Continued) Coil Operating Range 140 mW 70 mW Coil operating Range RF Data Isolation 3.5 140 mW at 100MHz/900MHz 80dB/72dB 80dB/72dB 70 mW at 3GHz 45dB 40dB 3 Umax. at 0 A Insertion loss Umax. at 0 A at 100MHz/900MHz 0.03dB/0.12dB 0.03dB/0.12dB 2.5 at 3GHz 0.35dB 0.40dB Voltage standing wave ratio (VSWR) Contacts in reset position. Contact po- 2 at 100MHz/900MHz/3GHz 1.05/1.20/1.20 1.05/1.20/1.40 sition might change during transporta- 1.5 tion and must be reset before use. Unom. nominal coil voltage Other Data 1 Unom. nominal coil voltage Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content Uop. min. 0.5 refer to the Product Compliance Support Center at Uop. min. Urel. min. www.te.com/customersupport/rohssupportcenter 0 Coil Operating Range Ambient temperature -55C to +85C -55-45 -35-25 -15-55 15 25 35 45 55 65 75 85 95 105115 125135 Thermal resistance <165K/W Ambient Temperature C Ambient Temperature C Category of environmental protection 140 mW 70 mW IEC 61810 RT III - wash tight Degree of protection, IEC 60529 IP 67, immersion cleanable Vibration resistance (functional) 35g, 10 to 1000Hz Unom = Nominal coil voltage 3.5 140 mW Shock resistance (functional), half sinus 11ms 50g Umax. = Upper limit of the operative range of 70 mW Shock resistance (destructive), half sinus 0.5ms 150g 3 the coil voltage (limiting voltage) Umax. at 0 A Terminal type SMT U = Lower limit of the operative range ofUmax. at 0 A op. min. Weight max. 2.5g 2.5 the coil voltage (reliable operate voltage) Resistance to soldering heat SMT Peak Value For latching relays Uset min. resp. Ureset min. IEC 60068-2-58 265C 2 Moisture sensitive level, JEDEC J-Std-020D MSL3 U = Lower limit of the operative range of rel. min. 1.5 Ultrasonic cleaning not recommended the coil voltage (reliable release voltage) Unom. nominal coil voltage Packaging/unit reel/400 pcs., box/400 or 2000 pcs. 1 Unom. nominal coil voltage Uop. min. All specications subject to change. Consult Tyco Electronics for latest specications. 5 of 12 0.5 Uop. min. Urel. min. 0 -55-45 -35-25 -15-55 15 25 35 45 55 65 75 85 95 105115 125135 Ambient Temperature C Ambient Temperature C Insulation Data 50 version 75 version Unom = Nominal coil voltage Initial dielectric strength Umax. = Upper limit of the operative range of between open contacts 600V rms the coil voltage (limiting voltage) between contact and coil 1000V rms U = Lower limit of the operative range of op. min. Initial surge withstand voltage the coil voltage (reliable operate voltage) between open contacts 1000V between contact and coil 1500V For latching relays Uset min. resp. Ureset min. U = Lower limit of the operative range of rel. min. the coil voltage (reliable release voltage) All specications subject to change. Consult Tyco Electronics for latest specications. 5 of 12 2 12-2013, Rev. 1213 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec- www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2013 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company