SCD
55A0811
SPECIFICATION CONTROL DRAWING
Date Revision
Title WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED,
1-12-17 AA
NORMAL WEIGHT, GENERAL PURPOSE, 600 VOLT
This specification sheet forms a part of the latest issue of Raychem Specification 55A.
PRIMARY INSULATION - RADIATION-CROSSLINKED,
MODIFIED ETFE
Primary insulation shall be of a contrasting
pigmentation to that of the jacket.
CONDUCTOR - TIN-COATED COPPER JACKET - RADIATION-CROSSLINKED,
MODIFIED ETFE
TABLE I. CONSTRUCTION DETAILS
DIAMETER OF FINISHED WIRE
STRANDED
PART WIRE CONDUCTOR
MAXIMUM
CONDUCTOR MAXIMUM
NUMBER SIZE STRANDING
RESISTANCE DIAMETER
WEIGHT
(inch)
1/ (AWG) (number x AWG)
AT 20C (inch)
(lbs/1000 ft.)
MINIMUM MAXIMUM (ohms/1000 ft.)
55A0811-28-* 28 7 x 36 .014 .016 68.6 .035 .002 1.30
55A0811-26-* 26 19 x 38 .018 .020 41.3 .040 .002 1.70
55A0811-24-* 24 19 x 36 .023 .024 26.2 .045 .002 2.30
55A0811-22-* 22 19 x 34 .029 .031 16.2 .050 .002 3.20
55A0811-20-* 20 19 x 32 .037 .039 9.88 .058 .002 4.70
55A0811-18-* 18 19 x 30 .046 .049 6.23 .070 .003 7.20
55A0811-16-* 16 19 x 29 .052 .055 4.81 .077 .003 9.00
55A0811-14-* 14 19 x 27 .065 .069 3.06 .094 .003 13.8
55A0811-12-* 12 37 x 28 .084 .089 2.02 .111 .003 20.5
55A0811-10-* 10 37 x 26 .106 .114 1.26 .134 .004 32.4
55A0811-8-* 8 133 x 29 .158 .173 .701 .195 .008 60.3
55A0811-6-* 6 133 x 27 .198 .217 .445 .241 .010 94.5
55A0811-4-* 4 133 x 25 .250 .274 .280 .310 .010 150.
55A0811-2-* 2 665 x 30 .320 .340 .183 .408 .012 249.
55A0811-1-* 1 817 x 30 .360 .380 .149 .470 .012 325.
55A0811-0-* 0 1045 x 30 .395 .425 .116 .510 .016 383.
55A0811-00-* 00 1330 x 30 .440 .475 .091 .570 .016 500.
55A0811-000-* 000 1665 x 30 .500 .540 .071 .610 .016 596.
55A0811-0000-* 0000 2109 x 30 .565 .605 .056 .675 .022 753.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Raychem, TE Connectivity, TE Connectivity (logo), and TE (logo) are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL.
Redwood City, CA 94063-3800
Page 1 of 2
Phone: 1-800-522-6752
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
Fax: 1-650-361-6297
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
2008-2017 Tyco Electronics Corporation. All rights reserved.
Page Revision SCD
SPECIFICATION CONTROL DRAWING
55A0811
2 of 2 AA
TABLE II. PERFORMANCE DETAILS
MANDREL DIAMETER WEIGHT
(inch) ( 3%) (lb) ( 3%)
PART
NUMBER
LIFE CYCLE, LIFE CYCLE,
COLD COLD
1/
IMMERSION, AND IMMERSION, AND
BEND BEND
ACCELERATED AGING ACCELERATED AGING
55A0811-28-* .375 .750 .250 2.00
55A0811-26-* .375 1.00 .500 3.00
55A0811-24-* .500 1.00 .750 3.00
55A0811-22-* .500 1.00 1.00 3.00
55A0811-20-* .500 1.00 1.50 4.00
55A0811-18-* .750 1.50 2.00 4.00
55A0811-16-* 1.00 1.50 2.00 5.00
55A0811-14-* 1.00 2.00 3.00 5.00
55A0811-12-* 1.50 2.00 3.00 5.00
55A0811-10-* 2.00 3.00 3.00 5.00
55A0811-8-* 3.00 4.00 4.00 6.00
55A0811-6-* 4.00 5.00 4.00 10.0
55A0811-4-* 5.00 6.00 4.00 10.0
55A0811-2-* 6.00 8.00 6.00 15.0
55A0811-1-* 8.00 10.0 6.00 15.0
55A0811-0-* 8.00 10.0 6.00 15.0
55A0811-00-* 10.0 12.0 8.00 20.0
55A0811-000-* 10.0 12.0 8.00 20.0
55A0811-0000-* 10.0 12.0 8.00 20.0
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150C INSULATION RESISTANCE:
Maximum continuous conductor temperature 5000 megohms for 1000 ft. (minimum), AWG 28-10
VOLTAGE RATING: 600 volts (rms) at sea level 3000 megohms for 1000 ft. (minimum), AWG 8-0000
ACCELERATED AGING (CROSSLINKING PROOF): INSULATION THICKNESS:
300 3C for 7 hours 0.003 in. (minimum) for primary insulation
BLOCKING: 200 3C for 24 hours 0.004 in. (minimum) for outer jacket
COLOR: White preferred 0.009 in. (minimum) for total insulation
CONCENTRICITY: 70% (minimum) LIFE CYCLE: 200 3C for 500 hours
FLAMMABILITY: Procedure 1, LOW TEMPERATURE-COLD BEND: -65 3C for 4 hours
3 seconds (maximum), 3 inches (maximum); SHRINKAGE: 200 3C for 6 hours,
no flaming of facial tissue 0.125 in. (maximum) in 12 inches
HUMIDITY RESISTANCE: Insulation Resistance, SMOKE TEST: 200 2C, no visible smoke
5000 megohms for 1000 ft. (minimum), AWG 28-10 SOLDERABILITY (AWG 10 and smaller only):
3000 megohms for 1000 ft. (minimum), AWG 8-0000 Per MIL-STD-202, Method 208, except without steam aging
IDENTIFICATION, COLOR STRIPING, AND BAND DURABILITY: SURFACE RESISTANCE:
125 cycles (250 strokes) (minimum), 500 g weight 500 meghoms-in. (minimum), both readings
IMMERSION: Diameter increase 5% (maximum); THERMAL SHOCK RESISTANCE: 150 3C,
no cracking, no dielectric breakdown 0.060 in. (maximum), AWG 28-12
INSULATION ELONGATION AND TENSILE STRENGTH: 0.100 in. (maximum), AWG 10-8
Elongation, 0.125 in. (maximum), AWG 6-0000
125% (minimum) for primary insulation, AWG 28-10 only VOLTAGE WITHSTAND (Post Environmental):
75% (minimum) for total insulation (primary insulation & jacket) 2500 volts (rms), 60 Hz
Tensile Strength, WICKING: 2.25 in. (maximum)
2
5000 lbf/in (minimum) for primary insulation WRAP TEST: 200 3C for 2 hours
2
5000 lbf/in (minimum) for total insulation (primary insulation & jacket)
INSULATION FLAWS: 1/ PART NUMBER:
Primary Insulation, The in the part numbers in Tables I and II shall be replaced
Spark Test, 1.5 kV (rms) at 60 Hz; 4.2 kV (rms) at 3 kHz by a color code designator.
Impulse Dielectric Test, 6.0 kV (peak) Example: AWG 22, white: 55A0811-22-9
Finished Wire, AWG 22, white with a black stripe: 55A0811-22-90
Spark Test, 5.7 kV (rms) at 3 kHz
Impulse Dielectric Test, 8.0 kV (peak)
1/ See footer section on page 1