General Purpose High Power PCB Relays PPottotter & Brumfielder & Brumfield T92 Series Two-pole Power Relay n 30/40/50A switching capability n Designed to control compressor loads to 3.5 tons, 110LRA / 25.3FLA n Meets requirements of UL 508 and UL 873 spacings - 8mm through air, 9.5mm over surface n Meets requirements of VDE 8mm spacing, 4kV dielectric coil-to- contact n Meets requirements of UL Class F construction n UL approved for 600VAC switching (1.5HP) n Screw terminal version (consult factory for availability, ratings) n Anti-explosive version available (Meets EN 60079-15) n WG version available (Meets EN 60335-1) Typical applications HVAC, residential / commercial appliances, industrial controls, charging 1) Approvals Contact ratings (T92 Type) (continued) UL E22575 CSA LR48471 VDE 40019600 Type Load Cycles Technical data of approved types on request. AgSnOInO 3 NO 40A, 240VAC, resistive 85C 50x10 3 Contact Data NO 30A, 120/277VAC, resistive (DC coil only) 200x10 3 Type T92 T92H NO 30A, 120/277VAC, resistive (AC coil only) 100x10 3 Contact arrangement 2 form A (NO) 2 form A (NO) NO 20A, 480VAC, resistive 100x10 3 2 form C (CO) NO 1.5HP, 120VAC, 2 pole making/breaking (Fig.1) 100x10 3 Rated voltage 277VAC NO 3HP, 240VAC, 3 phase (DC coil only) 100x10 3 Max. switching voltage 600VAC NO 3HP, 480VAC, 3 phase (DC coil only) 100x10 3 Rated current 30A/40A NO 3A NC 50A NO NO 2HP, 600VAC, 3 phase (DC coil only) 100x10 Overload current* 60A NO 4.5A NC 75A NO Special Ag Alloy X (Cd Free), wash tight 3 Contact material Ag Alloy NO 30A, 250VAC, resistive 100x10 3 Min. recommended contact load 500mA (NO), 12VAC or 5VDC NO 30A, 400VAC, resistive 100x10 3 100mA (NC), 12VAC or 5VDC NO 20A, 480VAC, resistive 100x10 Frequency of operation, with load 360 cycles per hour VDE Operate/release time max., AgCdO, flange mount relays 3 including bounce 25/25ms NO 20A, 400VAC 100x10 3 Initial contact resistance < 100 m at 6VDC 1A NC 3A, 400VAC 30x10 3 *Note: Minimum electrical endurance 50 cycles CO 20A NO / 3A NC, 400VAC 30x10 AgCdO, PC mount relays 3 NO 30A, 400VAC 100x10 1) 3 Contact ratings (T92H Type) NC 3A, 400VAC 30x10 3 UL508 CO 30A NO / 3A NC, 400VAC 30x10 3 NO 50A, 277VAC, resistive, 85C 6x10 Anti-explosion, sealed type 3 Note: Coil voltage 12-48VDC covered in UL approval NO 30A 250VAC, 25C 100x10 Anti-explosion, break device 3 NO 15A 480VAC 100x10 1) Contact ratings (T92 Type) ARI 780-86 Endurance Test (section 6.6): Type Load Cycles HVAC Definite Purpose Contactor Standard UL508 Normally Open Contacts AgCdO Single Phase/Two Pole (Both poles together switching a single load) 3 NO 40A, 277VAC, resistive 6x10 110 LRA, 25.3 FLA, 200K operations (DC Coil) 3 NO 30A, 120/277VAC, resistive 100x10 L1 L2 3 NO 10A, 600VAC, general purpose 100x10 3 NO 1HP, 120VAC 100x10 Figure 1 T1T2 3 NO 3HP, 240VAC 1x10 3 NO 1.5HP, 480 or 600VAC 100x10 Single Phase Per Pole (Single load per pole) 3 NO 110LRA/25.3FLA, 240VAC (DC coil only) 100x10 110 LRA, 18 FLA, 200K operations (DC Coil). 3 NO 60LRA/14FLA, 240VAC (AC coil only) 100x10 60 LRA, 14 FLA, 200K operations (AC Coil). 3 NO 3A, 240VAC, pilot duty 100x10 L1 L2 3 NO 20A, 28VDC, resistive 100x10 3 T1 T2 NO TV10, 120VAC 100x10 Figure 2 3 NC 3A, 277VAC 100x10 3 NC 2A, 480VAC 100x10 3 1) Contact ratings at 25C (unless otherwise noted) with relay properly vented. NC 1A, 600VAC 100x10 FLA, LRA ratings are compatible with 3.5 ton compressor applications. Mechanical endurance 6 T92 10x10 ops. 6 T92H 1x10 ops 1 09-2020, Rev. 0920 Catalog and product specification according Catalog and product data is subject to the Catalog product data, Definitions section, www.te.com to IEC 61810-1 and to be used only together terms of the disclaimer and all chapters of application notes and all specifications are 2012 Tyco Electronics Corporation, with the Definitions section. the Definitions section, available at subject to change. a TE Connectivity Ltd. company. AC Coil 30 A AC Coil 0 A DC Coil 30 Amp Contact Load DC Coil 0 Amp Contact Load General Purpose High Power PCB Relays PPottotter & Brumfielder & Brumfield T92 Series Two-pole Power Relay (Continued) Coil Data Coil Data (continued) Coil voltage range 5 to 110VDC 12 to 240VAC 120 Max. coil power 1.7W 4.0VA Max. coil temperature 155C 100 Coil insulation system according UL Class F 80 Coil versions, DC coil (D type) 60 Coil Rated Operate Release Coil Rated coil 2) 40 code voltage voltage voltage resistance power VDC VDC VDC 10% W 20 5 5 3.75 0.6 14.9 0 6 6 4.5 0.6 22 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 9 9 6.75 0.9 48 Applied Coil Voltage (% of Rated Nominal) 12 12 9 1.2 86 18 18 13.5 1.8 197 1.7W/ Insulation Data 22 22 16.5 2.2 294 Min. 0.41W Initial dielectric strength 24 24 18 2.4 350 hold between open contacts 1500V rms 36 36 27 3.6 767 between contact and coil 4000V rms 48 48 36 4.8 1390 between adjacent contact 2000V rms 110 110 82.5 11 7255 Initial surge withstand voltage 120 120 90 12 8514 between contact and coil 8kV 2) For T92H type, after the energization time of 100ms with rated voltage, the coil Initial insulation resistance 9 requires a reduction of the coil voltage to 50% of rated voltage. between insulated elements 1x10 Clearance/creepage Coil versions, AC coil (A type) between contact and coil 8mm clearance/9.5mm cr eepage Coil Rated Frequency Operate Release Coil Rated coil code voltage voltage voltage resistance power VAC Hz VAC, 60Hz VAC, 60Hz 10% VA Other Data 12 12 60 9.6 1.2 9.1 4 Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content 24 24 60 19.2 2.4 36.6 4 refer to the Product Compliance Support Center at 110 110 60 88 11 793 4 www.te.com/customersupport/rohssupportcenter 120 110/120 50/60 96 12 950 4 Ambient temperature 208 208 60 166.4 20.8 2841 4 DC coil -55C to 85C 240 220/240 50/60 192 24 3800 4 AC coil -55C to 65C 277 250/277 50/60 221.6 27.7 5485 4 Category of environmental protection Coil versions, AC coil (F type) IEC 61810 RTI - dust protected, Coil Rated Frequency Operate Release Coil Rated coil R TII - flux proof, RTIII - wash tight code voltage voltage voltage resistance power Vibration resistance (functional) 1.65mm max amplitude, 10-55 Hz VAC Hz VAC, 60Hz VAC, 60Hz 10% VA Shock resistance (functional) 10G for 11msec 12 12 50 9.6 1.2 11.2 3.5 Shock resistance (destructive) 100G 24 24 50 19.2 2.4 44.4 3.5 Terminal type PCB / Quick Connect / Screw 48 48 50 38.4 4.8 179.2 3.5 Weight 86g 240 240 50 192 24 4355 3.5 Resistance to soldering heat (for PCB Terminal) All figures are given for coil without preenergization, at ambient temperature +23C. IEC 60068-2-20 260C, 10s For A type, 110V/120V, 50/60Hz. Signify 50Hz Operation at Nominal 110V, 60 Hz Packaging/unit tray/30 pcs., box/120 pcs. Operation at Nominal 120V. 2 09-2020, Rev. 0920 Catalog and product specification according Catalog and product data is subject to the Catalog product data, Definitions section, www.te.com to IEC 61810-1 and to be used only together terms of the disclaimer and all chapters of application notes and all specifications are 2012 Tyco Electronics Corporation, with the Definitions section. the Definitions section, available at subject to change. a TE Connectivity Ltd. company.